The 100G-Q28-S28-C-0301 compatible assembly addresses a specific interoperability requirement: Brocade host identification on a 100G DAC link measuring 3m (10ft). Its interface configuration is QSFP28 to SFP28. This page explains the physical product, port-configuration checks and related part numbers so selection does not rely on connector appearance alone.
OEM Part Number: 100G-Q28-S28-C-0301HT Part Number: 100G-Q28-S28-C-0301
| HT Part Number | 100G-Q28-S28-C-0301 |
|---|---|
| Brocade Compatible | 100G-Q28-S28-C-0301 |
| Manufacturer | HT |
| Form Factor | QSFP28 to SFP28 |
| Max Data Rate | 100Gbps |
| Cable Type | Passive Twinax |
| Cable Length | 3m (10ft) |
| Wire AWG | 30AWG |
| Minimum Bend Radius | 60mm |
| Power Consumption | ≤0.125W |
| Power Supply | 3.3V |
| MTBF | =50 Million Hours |
| Jacket Material | PVC (OFNR) |
| Commercial Temperature Range | 0 to 70°C (32 to 158°F) |
| Modulation Format | QSFP28-4x 25G-NRZ SFP28-1x 25G-NRZ |
| Media | Copper |
| Application | 100G to 4x 25G Ethernet, Data Centers |
| Protocols | IEEE 802.3, QSFP28 MSA, SFF-8665 |
The listed modulation format is QSFP28-4x 25G-NRZ SFP28-1x 25G-NRZ. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.
The QSFP28 to SFP28 configuration divides the high-speed interface into multiple lower-speed connections. Verify the upstream lane assignment, downstream port speeds and breakout setting on the host before connecting the assembly. Each branch must attach to the correct remote interface.
A passive DAC has no separate optical conversion stage. Its low-power, low-latency operation is useful for short equipment links, but the assembly must remain within the length and signaling mode accepted by both hosts.
At 3m (10ft), this assembly can bridge non-aligned ports or adjacent racks while remaining a single direct-attach link. Support longer horizontal runs with suitable cable management and preserve space for cooling and future maintenance.
100G-Q28-S28-C-0301 occupies the middle of this family between 100G-Q28-S28-C-02501 at 2.5m (8ft) and 100G-Q28-S28-C-03501 at 3.5m (11ft). It adds 0.5m over the shorter option for extra routing clearance, while the next longer version adds another 0.5m. Measure the managed path and choose this version when its reach is sufficient without creating the slack associated with the longer assembly.
Check three layers before deployment: the host must accept the cable identification, the port must support the stated aggregate rate, and the lane configuration must match the attached interfaces. On breakout hardware, also confirm channelization and the mapping of every branch. These checks are particularly important when similar-looking ports operate at different speeds or under different firmware settings. For this assembly, the listed conductor specification is 30AWG; the minimum bend radius is 60mm; the stated power consumption is ≤0.125W; the jacket material is PVC (OFNR).
The rated power consumption is ≤0.125W. Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.
This assembly uses 30AWG conductors, PVC (OFNR) jacket, minimum bend radius 60mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.
The intended application is 100G to 4x 25G Ethernet, Data Centers. Listed interface and protocol references include IEEE 802.3, QSFP28 MSA, SFF-8665. Confirm that the host firmware and port configuration support the same operating mode.
Specify the OEM part number and fixed length, then provide the intended host configuration if the link uses channelized or breakout ports. Separate part numbers should be used for separate lengths. This gives the compatibility review enough information to check both the physical assembly and the intended operating mode. This page’s fixed configuration is 3m (10ft); another length must be quoted under its corresponding part number.
The verification process combines digital identification with a live link test and diagnostic observation. Host model, hardware revision and software release are useful inputs because qualification behavior can change between platform generations; those details allow platform-specific requirements to be reviewed before the cable is packed. Where supported by the host, link stability and diagnostic indications are reviewed together with the established link.
Available stock is generally dispatched within one to three working days after order confirmation, with production lead times advised for larger quantities. International express, air cargo and sea freight can be selected according to destination and carton volume; customer courier accounts and nominated forwarders are also accepted.
Functional inspection covers identification, link establishment and the condition of both connector assemblies. The cable is then protected against dust and connector damage and packed without sharp bends. Labels can include the customer reference and host-platform note when requested for a controlled deployment. Volume orders can include customer references on the labels and carton list.
No. It is an HT-manufactured compatible alternative for equipment that specifies Brocade 100G-Q28-S28-C-0301.
Provide the equipment manufacturer, model, port type, hardware revision and software release, together with the OEM reference, required length and quantity.
Protect both connector ends, keep the cable in a loose bend-safe coil and retain its part-number label so the length and compatibility identity remain traceable.
Only where both hosts explicitly support the complete interface and compatibility arrangement. Document each end and select the appropriate brand-specific product when required.