
Use this 5m (16ft) DAC cable for hosts expecting Extreme Networks 10414 and a 100G direct-attached interface. The assembly uses QSFP28 to QSFP28; lane, protocol and breakout considerations are documented alongside the verified table. Every alternative length remains a separate order code with its own technical page.
OEM Part Number: 10414HT Part Number: 10414
| HT Part Number | 10414 |
|---|---|
| Extreme Networks Compatible | 10414 |
| Manufacturer | HT |
| Form Factor | QSFP28 to QSFP28 |
| Max. Data Rate | 100Gbps |
| Media | Copper |
| Cable Type | Passive Twinax |
| Cable Length | 5m (16.4ft) |
| Jacket Material | PVC (OFNR) |
| Minimum Bend Radius | 45mm |
| Wire AWG | 26AWG |
| Max. Power Consumption | ≤0.5W |
| Modulation Format | 4x 25G-NRZ to 4x 25G-NRZ |
| Power Supply | 3.3V |
| MTBF | ≈50 Million Hours |
| Commercial Temperature Range | 0 to 70°C (32 to 158°F) |
| Application | 100G Ethernet |
| Protocols | QSFP28 MSA, SFF-8662, IEEE 802.3 |
The listed modulation format is 4x 25G-NRZ to 4x 25G-NRZ. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.
The intended application is 100G Ethernet. Listed interface and protocol references include QSFP28 MSA, SFF-8662, IEEE 802.3. Confirm that the host firmware and port configuration support the same operating mode.
A passive DAC has no separate optical conversion stage. Its low-power, low-latency operation is useful for short equipment links, but the assembly must remain within the length and signaling mode accepted by both hosts.
The 5m (16ft) length gives 10414 more freedom for adjacent-rack and row-end deployments. Longer copper runs need particular attention to routing weight and bend control; the DAC specification and host support must still match the intended link.
10414 is the longest of 7 verified length options in this family. Compared with 10413 at 3m (10ft), it provides 2m of additional reach for a longer vertical drop, a wider rack or an adjacent-cabinet route. Confirm that the complete path requires this length, because unused slack still needs supported, bend-safe storage.
Check three layers before deployment: the host must accept the cable identification, the port must support the stated aggregate rate, and the lane configuration must match the attached interfaces. On breakout hardware, also confirm channelization and the mapping of every branch. These checks are particularly important when similar-looking ports operate at different speeds or under different firmware settings. For this assembly, the listed conductor specification is 26AWG; the minimum bend radius is 45mm; the stated power consumption is ≤0.5W; the jacket material is PVC (OFNR).
The rated power consumption is ≤0.5W. Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.
This assembly uses 26AWG conductors, PVC (OFNR) jacket, minimum bend radius 45mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.
Specify the OEM part number and fixed length, then provide the intended host configuration if the link uses channelized or breakout ports. Separate part numbers should be used for separate lengths. This gives the compatibility review enough information to check both the physical assembly and the intended operating mode. Quantity and any labeling instructions should be attached specifically to 10414.
The verification process combines digital identification with a live link test and diagnostic observation. Host model, hardware revision and software release are useful inputs because qualification behavior can change between platform generations; those details allow platform-specific requirements to be reviewed before the cable is packed. The check includes link stability and diagnostic indications, followed by a final inspection of both ends.
Standard configurations normally ship within one to three working days, while production quantities are confirmed with the order. Worldwide courier services are available, with air or sea freight for consolidated shipments; freight-collect delivery and coordination with a customer’s logistics provider can be arranged.
Functional inspection covers identification, link establishment and the condition of both connector assemblies. The cable is then protected against dust and connector damage and packed without sharp bends. Labels can include the customer reference and host-platform note when requested for a controlled deployment. Volume orders can include customer references on the labels and carton list.
No. It is an HT-manufactured compatible alternative for equipment that specifies Extreme Networks 10414.
Only where both hosts explicitly support the complete interface and compatibility arrangement. Document each end and select the appropriate brand-specific product when required.
No. 10414 refers here to 5m (16ft). Every other verified length has a separate part number and page in the length list.
No. This is one complete direct-attach assembly. The ends are not detachable modules and should not be separated from the cable.