Factory built MTP®-16 Female APC with Offset Key breakout assembly with 16 Fibers on OS2 9/125μm fiber. The main trunk stays one cable until the fan-out point, which keeps pathways clear and makes moves and changes much easier to trace.
Standard lengths are 1m (3ft), 3m (10ft), 5m (16ft), 7m (23ft), 10m (33ft), 15m (49ft), 20m (66ft), 25m (82ft), 30m (98ft) and 40m (131ft). Because we are the manufacturer, any other length between or beyond these steps can be produced on request, with your choice of jacket color, labeling and packaging.
| Part Number | 16FMTPSMF |
|---|---|
| Manufacturer | HT |
| Connector A | US Conec MTP®-16 Female (Non-Pinned) APC with Offset Key |
| Connector B | US Conec MTP®-8 Female (Non-Pinned) APC |
| Fiber Mode | OS2 9/125μm |
| Wavelength | 1310/1550nm |
| Polish Type | APC to APC |
| Polarity | Crossover |
| Cable Jacket | Plenum (OFNP) |
| Fiber Count | 16 Fibers |
| Glass Fiber | G.657.A1 |
| Minimum Bend Radius | 10mm |
| Cable Outside Diameter (OD) | 3.0mm |
| Breakout Length | 0.5m |
| Installation Tensile Load | 66N |
| Tensile Strength | 60/120N (Long/Short Term) |
| Insertion Loss | ≤0.35dB (0.15dB Typ.) |
| Return Loss | ≥65dB |
| Attenuation at 1310nm | ≤0.35dB/km |
| Attenuation at 1550nm | ≤0.21dB/km |
| Operating Temperature | -10 to 60°C (14 to 140℉) |
| Storage Temperature | -10 to 70°C (14 to 158℉) |
In leaf-spine and GPU cluster cabling, this breakout replaces a cassette plus multiple jumpers with one tested assembly. The 16-fiber interface matches 400G SR8 optics, where all 16 fibers carry active transmit and receive lanes. Each leg is marked so port mapping is unambiguous during installation.
The fan-out point is factory molded and strain relieved, with each breakout leg built to the length shown in the specification table. Wiring follows the polarity scheme listed, so the lane order at the far end matches the transceiver requirements without on-site re-termination.
To order, quote 16FMTPSMF together with the length and quantity you need. The 1m (3ft) version is the standard model; Private labeling, custom packaging and project specific documentation are all handled in-house.
As a factory we can modify almost every detail of this product: length, jacket material and color, polarity, gender, breakout geometry, labeling and packaging. Non-standard variants are routine work for us, not a special project.
Products are packed in anti-static or PE bags with connector dust caps fitted, then boxed in sturdy export cartons. Custom labels, barcodes and carton markings are available on request.
Our test routine covers insertion loss, return loss and ferrule end face inspection on every assembly. Because testing is done in-house, custom variants receive exactly the same verification as standard models.