A successful 40G link depends on host acceptance as well as physical fit. This 40G-QSFP-4SFP-C-0501 compatible DAC assembly combines QSFP+ to 4 SFP+ with a fixed 5m (16ft) cable for Brocade equipment. The specifications, configuration guidance and live-link factory verification below describe the exact product supplied under this reference.
OEM Part Number: 40G-QSFP-4SFP-C-0501HT Part Number: 40G-QSFP-4SFP-C-0501
| HT Part Number | 40G-QSFP-4SFP-C-0501 |
|---|---|
| Brocade Compatible | 40G-QSFP-4SFP-C-0501 |
| Manufacturer | HT |
| Connector Type | QSFP+ to 4 SFP+ |
| Max Data Rate | 40Gbps |
| Minimum Bend Radius | 26mm |
| Wire AWG | 26AWG |
| Cable Length | 5m(16.4ft) |
| Jacket Material | PVC (OFNR) |
| Temperature | 0 to 70°C (32 to 158°F) |
| Protocols | SFF-8436, SFF-8431 and QSFP+ MSA |
This assembly uses 26AWG conductors, PVC (OFNR) jacket, minimum bend radius 26mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.
The QSFP+ to 4 SFP+ configuration divides the high-speed interface into multiple lower-speed connections. Verify the upstream lane assignment, downstream port speeds and breakout setting on the host before connecting the assembly. Each branch must attach to the correct remote interface.
A passive DAC has no separate optical conversion stage. Its low-power, low-latency operation is useful for short equipment links, but the assembly must remain within the length and signaling mode accepted by both hosts.
The 5m (16ft) length gives 40G-QSFP-4SFP-C-0501 more freedom for adjacent-rack and row-end deployments. Longer copper runs need particular attention to routing weight and bend control; the DAC specification and host support must still match the intended link.
40G-QSFP-4SFP-C-0501 occupies the middle of this family between 40G-QSFP-4SFP-C-0401 at 4m (13ft) and 40G-QSFP-4SFP-C-0701 at 7m (23ft). It adds 1m over the shorter option for extra routing clearance, while the next longer version adds another 2m. Measure the managed path and choose this version when its reach is sufficient without creating the slack associated with the longer assembly.
Check three layers before deployment: the host must accept the cable identification, the port must support the stated aggregate rate, and the lane configuration must match the attached interfaces. On breakout hardware, also confirm channelization and the mapping of every branch. These checks are particularly important when similar-looking ports operate at different speeds or under different firmware settings. For this assembly, the listed conductor specification is 26AWG; the minimum bend radius is 26mm; the jacket material is PVC (OFNR).
The intended application is determined by the host interface and protocol support. Listed interface and protocol references include SFF-8436, SFF-8431 and QSFP+ MSA. Confirm that the host firmware and port configuration support the same operating mode.
Specify the OEM part number and fixed length, then provide the intended host configuration if the link uses channelized or breakout ports. Separate part numbers should be used for separate lengths. This gives the compatibility review enough information to check both the physical assembly and the intended operating mode. Keep 40G-QSFP-4SFP-C-0501 associated with 5m (16ft) throughout the order and receiving record.
The verification process combines digital identification with a live link test and diagnostic observation. Host model, hardware revision and software release are useful inputs because qualification behavior can change between platform generations; those details allow platform-specific requirements to be reviewed before the cable is packed. The check includes link stability and diagnostic indications, followed by a final inspection of both ends.
Available stock is generally dispatched within one to three working days after order confirmation, with production lead times advised for larger quantities. Worldwide courier services are available, with air or sea freight for consolidated shipments; freight-collect delivery and coordination with a customer’s logistics provider can be arranged.
Functional inspection covers identification, link establishment and the condition of both connector assemblies. The cable is then protected against dust and connector damage and packed without sharp bends. Labels can include the customer reference and host-platform note when requested for a controlled deployment. Volume orders can include customer references on the labels and carton list.
No. It is an HT-manufactured compatible alternative for equipment that specifies Brocade 40G-QSFP-4SFP-C-0501.
Not necessarily. Both hosts must support the stated rate, identification, lane mapping and any required breakout configuration; mechanical compatibility alone is insufficient.
Provide the equipment manufacturer, model, port type, hardware revision and software release, together with the OEM reference, required length and quantity.
Protect both connector ends, keep the cable in a loose bend-safe coil and retain its part-number label so the length and compatibility identity remain traceable.