This 72 Fibers (Base-12) MTP® Elite Male trunk assembly is built for backbone cabling between racks, rows and distribution frames. OM4 50/125μm fiber, Plenum (OFNP) jacket and factory installed pulling protection make it a one-pull replacement for hours of field termination work.
Standard lengths are 1m (3ft), 3m (10ft), 5m (16ft), 7m (23ft), 10m (33ft), 15m (49ft), 20m (66ft), 25m (82ft), 30m (98ft) and 40m (131ft). Because we are the manufacturer, any other length between or beyond these steps can be produced on request, with your choice of jacket color, labeling and packaging.
| Part Number | 72FMTPOM4 |
|---|---|
| Manufacturer | HT |
| Connector A | US Conec MTP® Elite Male (Pinned) |
| Connector B | US Conec MTP® Elite Male (Pinned) |
| Fiber Mode | OM4 50/125μm |
| Wavelength | 850/1300nm |
| Polish Type | UPC to UPC |
| Polarity | Type B |
| Cable Jacket | Plenum (OFNP) |
| Fiber Count | 72 Fibers (Base-12) |
| Glass Fiber | Bend Insensitive Fiber |
| Cable Structure | Braided Tubing |
| Minimum Bend Radius | 7.5mm |
| Cable Outside Diameter (OD) | 11.7mm |
| Breakout Outside Diameter (OD) | 3.0mm |
| Breakout Length | 0.5m |
| Long-term Tensile Load | 80N |
| Short-term Tensile Load | 240N |
| Insertion Loss | ≤0.35dB (0.15dB Typ.) |
| Return Loss | ≥27dB |
| Attenuation at 850nm | ≤2.3dB/km |
| Attenuation at 1300nm | ≤0.6dB/km |
| Operating Temperature | -10 to 60°C (14 to 140℉) |
| Storage Temperature | -10 to 70°C (14 to 158℉) |
Install this trunk wherever many fibers must move between two termination points at once. The 72 Fibers (Base-12) construction concentrates the equivalent of many duplex jumpers into a single assembly, which is exactly what high density spine and leaf cabling needs. The assembly is shipped on a reel or coil with pulling protection, ready for a single pull through trays and conduits.
Inside the outer jacket, the fibers are grouped into sub-units that fan out to individually labeled connectors. This protects the fibers during pulling and keeps the breakout area compact at the panel. Type A, B and C polarity and male or female connectors are built to your panel schedule.
Please reference 72FMTPOM4 in your enquiry. The 1m (3ft) version is the standard model; Our sales team can also advise on polarity, gender and jacket choices if your project documentation is not final yet.
Our test routine covers insertion loss, return loss and ferrule end face inspection on every assembly. Because testing is done in-house, custom variants receive exactly the same verification as standard models.
Every cable is protected with dust caps and individual packaging before being boxed for shipment. Batch test reports and your own part number labels can be included in each bag.
We have manufactured fiber optic assemblies since 1995. MPO and MTP cabling is one of our core lines: fiber counts from 8 to 144, single mode and multimode, UPC and APC polish, trunk, jumper, harness and breakout formats. Send your drawing and we turn it into a ready to install assembly.