
The 800G OSFP (IHS/Finned Top) to 4x 200G OSFP (RHS/Flat Top)-800G-DAC-1M3FT compatible assembly addresses a specific interoperability requirement: Generic host identification on a 800G DAC link measuring 1m (3ft). Its interface configuration is 800G OSFP (IHS/Finned Top) to 4x 200G OSFP (RHS/Flat Top). This page explains the physical product, port-configuration checks and related part numbers so selection does not rely on connector appearance alone.
OEM Part Number: 800G OSFP (IHS/Finned Top) to 4x 200G OSFP (RHS/Flat Top)-800G-DAC-1M3FTHT Part Number: 800G OSFP (IHS/Finned Top) to 4x 200G OSFP (RHS/Flat Top)-800G-DAC-1M3FT
| HT Part Number | 800G OSFP (IHS/Finned Top) to 4x 200G OSFP (RHS/Flat Top)-800G-DAC-1M3FT |
|---|---|
| Manufacturer | HT |
| Form Factor | 800G OSFP (IHS/Finned Top) to 4x 200G OSFP (RHS/Flat Top) |
| Max Data Rate | 800Gbps |
| Media | Copper |
| Cable Type | Passive Breakout DAC |
| Cable Length | 1m (3ft) |
| Wire AWG | 28AWG |
| Minimum Bend Radius | 31mm |
| Max. Power Consumption | 0.1W (800G End)0.1W (200G Per End) |
| Jacket Material | PVC |
| Commercial Temperature Range | 0 to 70°C (32 to 158°F) |
| Protocols | OSFP MSA, IEEE 802.3ck, CMIS v4.0 |
| Modulation Format | 8x 100G PAM4 to Quad 2x 100G PAM4 |
The listed modulation format is 8x 100G PAM4 to Quad 2x 100G PAM4. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.
A passive DAC has no separate optical conversion stage. Its low-power, low-latency operation is useful for short equipment links, but the assembly must remain within the length and signaling mode accepted by both hosts.
At 1m (3ft), 800G OSFP (IHS/Finned Top) to 4x 200G OSFP (RHS/Flat Top)-800G-DAC-1M3FT is a practical choice for direct connections within one rack. Route the cable along the intended management path rather than pulling it diagonally across adjacent connectors, and leave enough clearance for insertion, removal and front-panel airflow.
800G OSFP (IHS/Finned Top) to 4x 200G OSFP (RHS/Flat Top)-800G-DAC-1M3FT occupies the middle of this family between 800G OSFP (IHS/Finned Top) to 4x 200G OSFP (RHS/Flat Top)-800G-DAC-0.5M2FT at 0.5m (2ft) and 800G OSFP (IHS/Finned Top) to 4x 200G OSFP (RHS/Flat Top)-800G-DAC-1.5M5FT at 1.5m (5ft). It adds 0.5m over the shorter option for extra routing clearance, while the next longer version adds another 0.5m. Measure the managed path and choose this version when its reach is sufficient without creating the slack associated with the longer assembly.
Check three layers before deployment: the host must accept the cable identification, the port must support the stated aggregate rate, and the lane configuration must match the attached interfaces. On breakout hardware, also confirm channelization and the mapping of every branch. These checks are particularly important when similar-looking ports operate at different speeds or under different firmware settings. For this assembly, the listed conductor specification is 28AWG; the minimum bend radius is 31mm; the stated power consumption is 0.1W (800G End)0.1W (200G Per End); the jacket material is PVC.
The rated power consumption is 0.1W (800G End)0.1W (200G Per End). Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.
This assembly uses 28AWG conductors, PVC jacket, minimum bend radius 31mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.
The intended application is determined by the host interface and protocol support. Listed interface and protocol references include OSFP MSA, IEEE 802.3ck, CMIS v4.0. Confirm that the host firmware and port configuration support the same operating mode.
The 800G OSFP (IHS/Finned Top) to 4x 200G OSFP (RHS/Flat Top) configuration divides the high-speed interface into multiple lower-speed connections. Verify the upstream lane assignment, downstream port speeds and breakout setting on the host before connecting the assembly. Each branch must attach to the correct remote interface.
Specify the OEM part number and fixed length, then provide the intended host configuration if the link uses channelized or breakout ports. Separate part numbers should be used for separate lengths. This gives the compatibility review enough information to check both the physical assembly and the intended operating mode. This page’s fixed configuration is 1m (3ft); another length must be quoted under its corresponding part number.
The verification process combines digital identification with a live link test and diagnostic observation. Host model, hardware revision and software release are useful inputs because qualification behavior can change between platform generations; those details allow platform-specific requirements to be reviewed before the cable is packed. Both connectors are examined before the operating test, which includes link stability and diagnostic indications.
Standard configurations normally ship within one to three working days, while production quantities are confirmed with the order. International express, air cargo and sea freight can be selected according to destination and carton volume; customer courier accounts and nominated forwarders are also accepted.
Functional inspection covers identification, link establishment and the condition of both connector assemblies. The cable is then protected against dust and connector damage and packed without sharp bends. Labels can include the customer reference and host-platform note when requested for a controlled deployment. Neutral packaging and customer-specific packing documentation are available on request.
No. It is manufactured by HT under our own manufacturer identity.
No. This is one complete direct-attach assembly. The ends are not detachable modules and should not be separated from the cable.
No. Use a supported, bend-safe service loop and observe the listed minimum bend radius. Do not crease the cable or tighten ties around the connector boots.
Not necessarily. Both hosts must support the stated rate, identification, lane mapping and any required breakout configuration; mechanical compatibility alone is insufficient.