
Use this 3m (10ft) AOC cable for hosts expecting Arista Networks AOC-Q-Q-100G-3M and a 100G direct-attached interface. The assembly uses QSFP28 to QSFP28; lane, protocol and breakout considerations are documented alongside the verified table. Every alternative length remains a separate order code with its own technical page.
OEM Part Number: AOC-Q-Q-100G-3MHT Part Number: AOC-Q-Q-100G-3M
| HT Part Number | AOC-Q-Q-100G-3M |
|---|---|
| Arista Networks Compatible | AOC-Q-Q-100G-3M |
| Manufacturer | HT |
| Form Factor | QSFP28 to QSFP28 |
| Max Data Rate | 100Gbps |
| Minimum Bend Radius | 30mm |
| Cable Length | 3m (9.84ft) |
| Jacket Material | OFNP |
| Cable Type | Optical Cable |
| Receiver Type | PIN |
| Transmitter Type | VSCEL |
| Wavelength | 850nm |
| Power Consumption | <2.2W |
| MTBF | ≈50 Million Hours |
| Power supply | 3.3V |
| Commercial Temperature Range | 0 to 70°C (32 to 158°F) |
| Protocols | IEEE 802.3 bm, SFF-8665 |
| CDR (Clock and Data Recovery) | TX & RX Built-in CDR |
| Modulation Format | 4x 25G-NRZ to 4x 25G-NRZ |
| Application | 100G Ethernet |
The listed modulation format is 4x 25G-NRZ to 4x 25G-NRZ. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.
The optical engines and fiber are permanently integrated into this AOC. There are no detachable optical modules to clean or exchange. Handle the complete assembly by its connector housings and cable, and keep both ends matched to the same interface specification.
At 3m (10ft), this assembly can bridge non-aligned ports or adjacent racks while remaining a single direct-attach link. Support longer horizontal runs with suitable cable management and preserve space for cooling and future maintenance.
AOC-Q-Q-100G-3M occupies the middle of this family between AOC-Q-Q-100G-2M at 2m (7ft) and AOC-Q-Q-100G-5M at 5m (16ft). It adds 1m over the shorter option for extra routing clearance, while the next longer version adds another 2m. Measure the managed path and choose this version when its reach is sufficient without creating the slack associated with the longer assembly.
Check three layers before deployment: the host must accept the cable identification, the port must support the stated aggregate rate, and the lane configuration must match the attached interfaces. On breakout hardware, also confirm channelization and the mapping of every branch. These checks are particularly important when similar-looking ports operate at different speeds or under different firmware settings. For this assembly, the minimum bend radius is 30mm; the stated power consumption is <2.2W; the jacket material is OFNP.
The rated power consumption is <2.2W. Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.
This assembly uses OFNP jacket, minimum bend radius 30mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.
The intended application is 100G Ethernet. Listed interface and protocol references include IEEE 802.3 bm, SFF-8665. Confirm that the host firmware and port configuration support the same operating mode.
Specify the OEM part number and fixed length, then provide the intended host configuration if the link uses channelized or breakout ports. Separate part numbers should be used for separate lengths. This gives the compatibility review enough information to check both the physical assembly and the intended operating mode. Quantity and any labeling instructions should be attached specifically to AOC-Q-Q-100G-3M.
The verification process combines digital identification with a live link test and diagnostic observation. Host model, hardware revision and software release are useful inputs because qualification behavior can change between platform generations; those details allow platform-specific requirements to be reviewed before the cable is packed. The check includes receive activity and diagnostic indications, followed by a final inspection of both ends.
Available stock is generally dispatched within one to three working days after order confirmation, with production lead times advised for larger quantities. Worldwide courier services are available, with air or sea freight for consolidated shipments; freight-collect delivery and coordination with a customer’s logistics provider can be arranged.
Functional inspection covers identification, link establishment and the condition of both connector assemblies. The cable is then protected against dust and connector damage and packed without sharp bends. Labels can include the customer reference and host-platform note when requested for a controlled deployment. Neutral packaging and customer-specific packing documentation are available on request.
No. It is an HT-manufactured compatible alternative for equipment that specifies Arista Networks AOC-Q-Q-100G-3M.
Not necessarily. Both hosts must support the stated rate, identification, lane mapping and any required breakout configuration; mechanical compatibility alone is insufficient.
Provide the equipment manufacturer, model, port type, hardware revision and software release, together with the OEM reference, required length and quantity.
Protect both connector ends, keep the cable in a loose bend-safe coil and retain its part-number label so the length and compatibility identity remain traceable.