
The AOC-Q28-4SFP28-25G-30M compatible assembly addresses a specific interoperability requirement: Dell host identification on a 100G AOC link measuring 30m (98ft). Its interface configuration is QSFP28 to 4x SFP28. This page explains the physical product, port-configuration checks and related part numbers so selection does not rely on connector appearance alone.
OEM Part Number: AOC-Q28-4SFP28-25G-30MHT Part Number: AOC-Q28-4SFP28-25G-30M
| HT Part Number | AOC-Q28-4SFP28-25G-30M |
|---|---|
| Dell Compatible | AOC-Q28-4SFP28-25G-30M |
| Manufacturer | HT |
| Form Factor | QSFP28 to 4x SFP28 |
| Max. Data Rate | 100Gbps |
| Cable Length | 30m (98ft) |
| Cable Type | Breakout AOC |
| Wavelength | 850nm |
| Minimum Bend Radius | 30mm |
| Transmitter Type | VCSEL |
| Receiver Type | PIN |
| Max. Power Consumption | 2.2W (QSFP28 End)0.8W (SFP28 Per End) |
| Modulation Format | QSFP28-4x 25G-NRZ SFP28-1x 25G-NRZ |
| CDR (Clock and Data Recovery) | TX & RX Built-in CDR |
| Jacket Material | OFNP |
| DDM/DOM | Supported |
| Commercial Temperature Range | 0 to 70°C (32 to 158°F) |
| Protocols | QSFP28 MSA, SFP28 MSA |
The listed modulation format is QSFP28-4x 25G-NRZ SFP28-1x 25G-NRZ. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.
The QSFP28 to 4x SFP28 configuration divides the high-speed interface into multiple lower-speed connections. Verify the upstream lane assignment, downstream port speeds and breakout setting on the host before connecting the assembly. Each branch must attach to the correct remote interface.
The optical engines and fiber are permanently integrated into this AOC. There are no detachable optical modules to clean or exchange. Handle the complete assembly by its connector housings and cable, and keep both ends matched to the same interface specification.
For this 30m (98ft) version, prepare the destination pathway before connecting either end. A longer assembly can cross separated equipment positions, but its weight and service slack must remain supported without blocking airflow. Handle the integrated optical cable and both optical engines as one factory-terminated product and never pull a connector into position by the cable. Within this family, AOC-Q28-4SFP28-25G-25M is shorter at 25m (82ft), while AOC-Q28-4SFP28-25G-50M is the next longer choice at 50m (164ft); comparing those two boundaries helps avoid both tension and unnecessary slack.
AOC-Q28-4SFP28-25G-30M occupies the middle of this family between AOC-Q28-4SFP28-25G-25M at 25m (82ft) and AOC-Q28-4SFP28-25G-50M at 50m (164ft). It adds 5m over the shorter option for extra routing clearance, while the next longer version adds another 20m. Measure the managed path and choose this version when its reach is sufficient without creating the slack associated with the longer assembly.
Check three layers before deployment: the host must accept the cable identification, the port must support the stated aggregate rate, and the lane configuration must match the attached interfaces. On breakout hardware, also confirm channelization and the mapping of every branch. These checks are particularly important when similar-looking ports operate at different speeds or under different firmware settings. For this assembly, the minimum bend radius is 30mm; the stated power consumption is 2.2W (QSFP28 End)0.8W (SFP28 Per End); the jacket material is OFNP.
The rated power consumption is 2.2W (QSFP28 End)0.8W (SFP28 Per End). Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.
This assembly uses OFNP jacket, minimum bend radius 30mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.
The intended application is determined by the host interface and protocol support. Listed interface and protocol references include QSFP28 MSA, SFP28 MSA. Confirm that the host firmware and port configuration support the same operating mode.
Specify the OEM part number and fixed length, then provide the intended host configuration if the link uses channelized or breakout ports. Separate part numbers should be used for separate lengths. This gives the compatibility review enough information to check both the physical assembly and the intended operating mode. Quantity and any labeling instructions should be attached specifically to AOC-Q28-4SFP28-25G-30M.
The verification process combines digital identification with a live link test and diagnostic observation. Host model, hardware revision and software release are useful inputs because qualification behavior can change between platform generations; those details allow platform-specific requirements to be reviewed before the cable is packed. The check includes receive activity and diagnostic indications, followed by a final inspection of both ends.
Standard configurations normally ship within one to three working days, while production quantities are confirmed with the order. International express, air cargo and sea freight can be selected according to destination and carton volume; customer courier accounts and nominated forwarders are also accepted.
Functional inspection covers identification, link establishment and the condition of both connector assemblies. The cable is then protected against dust and connector damage and packed without sharp bends. Labels can include the customer reference and host-platform note when requested for a controlled deployment. Standard protective packing is used by default, with project documentation arranged when requested.
No. It is an HT-manufactured compatible alternative for equipment that specifies Dell AOC-Q28-4SFP28-25G-30M.
No. AOC-Q28-4SFP28-25G-30M refers here to 30m (98ft). Every other verified length has a separate part number and page in the length list.
No. This is one complete direct-attach assembly. The ends are not detachable modules and should not be separated from the cable.
No. Use a supported, bend-safe service loop and observe the listed minimum bend radius. Do not crease the cable or tighten ties around the connector boots.