Built for hosts recognizing AVM762, this HT-manufactured SFP28 module delivers 25G transmission at 1310nm. Its rated reach is 300m, with Duplex LC as the physical interface. The specifications and engineering guidance below support network teams verify host acceptance as well as physical interface fit, while keeping HT manufacture separate from the OEM cross-reference.
OEM Part Number: AVM762HT Part Number: SFP-25GLRS-31
| NETGEAR Compatible | AVM762 |
|---|---|
| Manufacturer | HT |
| HT Part Number | SFP-25GLRS-31 |
| Form Factor | SFP28 |
| Max Data Rate | 25.78125Gb/s |
| Wavelength | 1310nm |
| Max Cable Distance | 300m |
| Connector | Duplex LC |
| Media | SMF |
| Transmitter Type | DFB |
| Receiver Type | PIN |
| TX Power | -5~2dBm |
| Receiver Sensitivity | <-8.5dBm |
| Power Budget | 3.5W |
| Modulation | NRZ |
| Power Consumption | 1W |
| Extinction Ratio | 3W |
| CDR | Supported |
| FEC Function | Supported |
| Temperature Range | 0 to 70°C (32 to 158°F) |
| Protocols | SFF-8472, SFF-8024, SFF-8431, SFF-8432, IEEE 802.3 by, IEEE 802.3cc |
| DOM | Supported |
| Application | 25G Ethernet/ Data Center |
Use this module for equipment interconnection over the specified single-mode fiber plant, including enterprise backbone, campus, metro or data-center interconnect links according to its rated distance. Confirm that both ends use the same optical standard and wavelength plan, and allow for connector, splice and patch-panel loss within the stated power budget.
Before deployment, check the host port type, supported data rate and firmware requirements. The 25G interface configuration must match the remote equipment; sharing a SFP28 housing alone does not make two transceiver types interoperable.
The single-mode link budget should include fiber attenuation, connectors, splices and panels over the intended 300m route. Keep the Duplex LC interface clean and match the remote optical standard. Consider receiver overload as well as insufficient power on short links.
Compatibility testing for AVM762 combines identification with a live link and available transmit, receive and alarm information. Connector condition is inspected separately. Equipment model, hardware revision and software release can be reviewed before dispatch where platform behavior is uncertain.
For this model, the specified transmit-power range is -5~2dBm; receiver sensitivity is <-8.5dBm; the stated optical power budget is 3.5W. Digital diagnostics make later maintenance easier when baseline values are captured at installation. Save the initial readings with the port and OEM reference, then investigate meaningful changes rather than reacting to a single transient value. Diagnostic support depends on the host as well as the module, so unavailable fields should be confirmed with the platform documentation. Diagnostic monitoring is listed as Supported. Before every insertion, keep dust caps in place until the patch lead is ready, avoid touching the optical end face and use an appropriate inspection and cleaning procedure. Do not look into an active optical interface.
Check three layers before deployment: host acceptance of the module identity, port support for the stated rate, and a matching optical standard at the remote interface. For breakout operation, confirm lane configuration too. Similar-looking cages can behave differently across speeds and firmware settings. For this model, the principal parameters are data rate 25.78125Gb/s, wavelength 1310nm, rated reach 300m.
When ordering, specify AVM762, SFP-25GLRS-31, quantity and intended host platform. Project labels can repeat these details for receiving and asset records. Neutral labels, customer packaging and project-specific compatibility review are available on request.
Standard configurations normally ship within one to three working days, with production lead times confirmed for larger quantities. International courier, air freight and sea freight are available; customer courier accounts and nominated forwarders are accepted.
Before packing, the module receives interface inspection, identification and link checks. Protective packaging avoids pressure on the connector and latch. Customer references, rack groups and project packing lists can be added for volume orders.
No. It is an HT-manufactured compatible alternative for equipment that specifies AVM762, not an original NETGEAR-branded module.
Use Duplex LC with SMF. The specified maximum reach is 300m, subject to fiber quality and total link loss.
Only when the two ends share the same optical standard, wavelength plan and supported data rate. Check the exact part numbers and link budget rather than relying only on the module form factor.