IBM BNT BN-SP-CBL-10M Compatible 10G SFP+ Active Copper Twinax Cable, 10m (33ft)

IBM BNT BN-SP-CBL-10M Compatible 10G SFP+ Active Copper Twinax Cable, 10m (33ft)

The BNT BN-SP-CBL-10M compatible assembly addresses a specific interoperability requirement: IBM host identification on a 10G ACC link measuring 10m (33ft). Its interface configuration is SFP+ to SFP+. This page explains the physical product, port-configuration checks and related part numbers so selection does not rely on connector appearance alone.

OEM Part Number: BNT BN-SP-CBL-10MHT Part Number: BNT BN-SP-CBL-10M

Product Highlights

  • Compatible alternative to IBM BNT BN-SP-CBL-10M
  • 10G connectivity at 10Gbps
  • Interface configuration: SFP+ to SFP+
  • Fixed length and part number: 10m (33ft), BNT BN-SP-CBL-10M
  • Cable construction: Active Twinax
  • Conductor specification: 26AWG
  • Maximum power consumption: ≤0.5W
  • Minimum bend radius: 30mm

Specifications

HT Part NumberBNT BN-SP-CBL-10M
IBM CompatibleBN-SP-CBL-10M
ManufacturerHT
Connector TypeSFP+ to SFP+
Max Data Rate10Gbps
Minimum Bend Radius30mm
Wire AWG26AWG
Cable Length10m (32.81ft)
Jacket MaterialPVC (OFNR)
Cable TypeActive Twinax
Temperature0 to 70°C (32 to 158°F)
Power Consumption≤0.5W
Power Supply3.3V
Protocols1x InfiniBand QDR, DDR, SDR, 10 Gigabit Ethernet, Fibre Channel

Power and Thermal Planning

The rated power consumption is ≤0.5W. Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.

Position Within the Length Range

BNT BN-SP-CBL-10M is the longest of 4 verified length options in this family. Compared with 81Y8297 at 5m (16ft), it provides 5m of additional reach for a longer vertical drop, a wider rack or an adjacent-cabinet route. Confirm that the complete path requires this length, because unused slack still needs supported, bend-safe storage.

Interoperability and Configuration Checks

Check three layers before deployment: the host must accept the cable identification, the port must support the stated aggregate rate, and the lane configuration must match the attached interfaces. On breakout hardware, also confirm channelization and the mapping of every branch. These checks are particularly important when similar-looking ports operate at different speeds or under different firmware settings. For this assembly, the listed conductor specification is 26AWG; the minimum bend radius is 30mm; the stated power consumption is ≤0.5W; the jacket material is PVC (OFNR).

Cable Construction and Routing

This assembly uses 26AWG conductors, PVC (OFNR) jacket, minimum bend radius 30mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.

Network and Protocol Considerations

The intended application is determined by the host interface and protocol support. Listed interface and protocol references include 1x InfiniBand QDR, DDR, SDR, 10 Gigabit Ethernet, Fibre Channel. Confirm that the host firmware and port configuration support the same operating mode.

Length Selection and Installation Planning

A 10m (33ft) run can remain tidy when its pathway and service allowance are planned together. Keep the complete copper assembly and both connector housings away from tight cable-tie pressure, verify bend control at changes of direction and ensure that neither port supports the assembly’s weight. Record the exact order code after acceptance. The next shorter verified assembly is 81Y8297 at 5m (16ft), which is the better comparison when the managed route leaves substantial unused cable.

Ordering Information

Specify the OEM part number and fixed length, then provide the intended host configuration if the link uses channelized or breakout ports. Separate part numbers should be used for separate lengths. This gives the compatibility review enough information to check both the physical assembly and the intended operating mode. This page’s fixed configuration is 10m (33ft); another length must be quoted under its corresponding part number.

IBM Compatibility and Factory Testing

The verification process combines digital identification with a live link test and diagnostic observation. Host model, hardware revision and software release are useful inputs because qualification behavior can change between platform generations; those details allow platform-specific requirements to be reviewed before the cable is packed. The check includes link stability and diagnostic indications, followed by a final inspection of both ends.

Shipping and Lead Time

Available stock is generally dispatched within one to three working days after order confirmation, with production lead times advised for larger quantities. Delivery can be arranged by courier, air freight or sea freight, and goods may instead be handed to an appointed forwarder or shipped on the customer’s courier account.

Quality Assurance and Packaging

Functional inspection covers identification, link establishment and the condition of both connector assemblies. The cable is then protected against dust and connector damage and packed without sharp bends. Labels can include the customer reference and host-platform note when requested for a controlled deployment. Standard protective packing is used by default, with project documentation arranged when requested.

Frequently Asked Questions

Is this an original IBM cable?

No. It is an HT-manufactured compatible alternative for equipment that specifies IBM BNT BN-SP-CBL-10M.

Are separate transceivers or patch leads required?

No. This is one complete direct-attach assembly. The ends are not detachable modules and should not be separated from the cable.

Can excess cable be folded into a compact bundle?

No. Use a supported, bend-safe service loop and observe the listed minimum bend radius. Do not crease the cable or tighten ties around the connector boots.

Will any matching connector operate at the same speed?

Not necessarily. Both hosts must support the stated rate, identification, lane mapping and any required breakout configuration; mechanical compatibility alone is insufficient.


About us

China Factory:No 168 Golden Ground Industrial Area;
Philippines Address:Makati City,Metro Manila, Philippines

Products catalogues

For products catalogue/data sheets or any general inquiry, please email info@huihongfiber.com and we will reply with details.

Customer Support

For customer support, please email sales@huihongfiber.com; our support team will get back to you as soon as possible.