Philippines Fiber Optics

Connect the people, connect the world ...

Fiber Optic Cables

Arista Networks C-Q200-4S50-0.5M Compatible 200G QSFP56 4 x 50G PAM4 to 4 x 50G SFP56 50G PAM4 Passive Copper Breakout Cable, 0.5m (2ft)

Arista Networks C-Q200-4S50-0.5M Compatible 200G QSFP56 4 x 50G PAM4 to 4 x 50G SFP56 50G PAM4 Passive Copper Breakout Cable, 0.5m (2ft)

A successful 200G link depends on host acceptance as well as physical fit. This C-Q200-4S50-0.5M compatible DAC assembly combines QSFP56 to 4x SFP56 with a fixed 0.5m (2ft) cable for Arista Networks equipment. The specifications, configuration guidance and live-link factory verification below describe the exact product supplied under this reference.

OEM Part Number: C-Q200-4S50-0.5MHT Part Number: C-Q200-4S50-0.5M

Product Highlights

  • Compatible alternative to Arista Networks C-Q200-4S50-0.5M
  • 200G connectivity at 200Gbps
  • Interface configuration: QSFP56 to 4x SFP56
  • Fixed length and part number: 0.5m (2ft), C-Q200-4S50-0.5M
  • Cable construction: Passive Breakout DAC
  • Conductor specification: 30AWG
  • Maximum power consumption: 0.1W (QSFP56 End)0.1W (SFP56 Per End)
  • Minimum bend radius: 35mm

Specifications

HT Part NumberC-Q200-4S50-0.5M
Arista Networks CompatibleC-Q200-4S50-0.5M
ManufacturerHT
Form FactorQSFP56 to 4x SFP56
Max. Data Rate200Gbps
MediaCopper
Cable TypePassive Breakout DAC
Minimum Bend Radius35mm
Wire AWG30AWG
Cable Length0.5m (2ft)
Jacket MaterialPVC (OFNR)
Max. Power Consumption0.1W (QSFP56 End)0.1W (SFP56 Per End)
Modulation FormatQSFP56-4x 50G-PAM4SFP56-50G-PAM4
DDM/DOMNot Supported
Commercial TemperatureRange0 to 70°C (32 to 158°F)
ProtocolsSFF-8661, SFF-8432, IEEE 802.3bs-200GAUI-4, IEEE802.3cd-50GAUI-1, SFP-8636, SFF-8472

Signal and Lane Configuration

The listed modulation format is QSFP56-4x 50G-PAM4SFP56-50G-PAM4. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.

Network and Protocol Considerations

The intended application is determined by the host interface and protocol support. Listed interface and protocol references include SFF-8661, SFF-8432, IEEE 802.3bs-200GAUI-4, IEEE802.3cd-50GAUI-1, SFP-8636, SFF-8472. Confirm that the host firmware and port configuration support the same operating mode.

Breakout Port Mapping

The QSFP56 to 4x SFP56 configuration divides the high-speed interface into multiple lower-speed connections. Verify the upstream lane assignment, downstream port speeds and breakout setting on the host before connecting the assembly. Each branch must attach to the correct remote interface.

Passive Copper Operation

A passive DAC has no separate optical conversion stage. Its low-power, low-latency operation is useful for short equipment links, but the assembly must remain within the length and signaling mode accepted by both hosts.

Length Selection and Installation Planning

The 0.5m (2ft) length is suited to closely aligned ports where excessive slack would obstruct airflow or complicate dressing. Measure the actual port-to-port path before choosing C-Q200-4S50-0.5M; even a short assembly must retain the specified bend radius and should never be pulled tight behind the equipment.

Position Within the Length Range

C-Q200-4S50-0.5M is the shortest of 4 verified length options in this family. It is the preferred choice when the port positions are close and cable slack must be kept to a minimum. The next option is C-Q200-4S50-1M at 1m (3ft), adding 0.5m for a less direct routing path; selecting it unnecessarily would leave more cable to dress.

Interoperability and Configuration Checks

Check three layers before deployment: the host must accept the cable identification, the port must support the stated aggregate rate, and the lane configuration must match the attached interfaces. On breakout hardware, also confirm channelization and the mapping of every branch. These checks are particularly important when similar-looking ports operate at different speeds or under different firmware settings. For this assembly, the listed conductor specification is 30AWG; the minimum bend radius is 35mm; the stated power consumption is 0.1W (QSFP56 End)0.1W (SFP56 Per End); the jacket material is PVC (OFNR).

Power and Thermal Planning

The rated power consumption is 0.1W (QSFP56 End)0.1W (SFP56 Per End). Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.

Cable Construction and Routing

This assembly uses 30AWG conductors, PVC (OFNR) jacket, minimum bend radius 35mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.

Ordering Information

Specify the OEM part number and fixed length, then provide the intended host configuration if the link uses channelized or breakout ports. Separate part numbers should be used for separate lengths. This gives the compatibility review enough information to check both the physical assembly and the intended operating mode. This page’s fixed configuration is 0.5m (2ft); another length must be quoted under its corresponding part number.

Arista Networks Compatibility and Factory Testing

The verification process combines digital identification with a live link test and diagnostic observation. Host model, hardware revision and software release are useful inputs because qualification behavior can change between platform generations; those details allow platform-specific requirements to be reviewed before the cable is packed. The check includes link stability and diagnostic indications, followed by a final inspection of both ends.

Shipping and Lead Time

Available stock is generally dispatched within one to three working days after order confirmation, with production lead times advised for larger quantities. International express, air cargo and sea freight can be selected according to destination and carton volume; customer courier accounts and nominated forwarders are also accepted.

Quality Assurance and Packaging

Functional inspection covers identification, link establishment and the condition of both connector assemblies. The cable is then protected against dust and connector damage and packed without sharp bends. Labels can include the customer reference and host-platform note when requested for a controlled deployment. Standard protective packing is used by default, with project documentation arranged when requested.

Frequently Asked Questions

Is this an original Arista Networks cable?

No. It is an HT-manufactured compatible alternative for equipment that specifies Arista Networks C-Q200-4S50-0.5M.

How should an unused assembly be stored?

Protect both connector ends, keep the cable in a loose bend-safe coil and retain its part-number label so the length and compatibility identity remain traceable.

Can different brands be connected with the same assembly?

Only where both hosts explicitly support the complete interface and compatibility arrangement. Document each end and select the appropriate brand-specific product when required.

Does this order code cover multiple lengths?

No. C-Q200-4S50-0.5M refers here to 0.5m (2ft). Every other verified length has a separate part number and page in the length list.


About us

China Factory:No 168 Golden Ground Industrial Area;
Philippines Address:Makati City,Metro Manila, Philippines

Products catalogues

For products catalogue/data sheets or any general inquiry, please email info@huihongfiber.com and we will reply with details.

Customer Support

For customer support, please email sales@huihongfiber.com; our support team will get back to you as soon as possible.