A successful 100G link depends on host acceptance as well as physical fit. This C-Z100-Q100-1M compatible DAC assembly combines SFP-DD to QSFP56 with a fixed 1m (3ft) cable for Arista equipment. The specifications, configuration guidance and live-link factory verification below describe the exact product supplied under this reference.
OEM Part Number: C-Z100-Q100-1MHT Part Number: C-Z100-Q100-1M
| HT Part Number | C-Z100-Q100-1M |
|---|---|
| Arista Compatible | C-Z100-Q100-1M |
| Manufacturer | HT |
| Form Factor | SFP-DD to QSFP56 |
| Max. Data Rate | 100Gbps |
| Media | Copper |
| Cable Type | Passive Twinax |
| Cable Length | 1m (3ft) |
| Jacket Material | PVC (OFNR) |
| Minimum Bend Radius | 17mm |
| Wire AWG | 30AWG |
| Max. Power Consumption | 0.1W |
| Modulation Format | SFP-DD-2x 50G-PAM4QSFP56-2x 50G-PAM4 |
| Commercial Temperature Range | 0 to 70°C (32 to 158°F) |
| Application | 100G Ethernet, 128G Fibre Channel |
| Protocols | SFPDD: SFP-DD MSA, SFP-DD MIS, IEEE 802.3cdQSFP56: SFF-8661, SFF-8636, IEEE 802.3cd |
The listed modulation format is SFP-DD-2x 50G-PAM4QSFP56-2x 50G-PAM4. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.
Check three layers before deployment: the host must accept the cable identification, the port must support the stated aggregate rate, and the lane configuration must match the attached interfaces. On breakout hardware, also confirm channelization and the mapping of every branch. These checks are particularly important when similar-looking ports operate at different speeds or under different firmware settings. For this assembly, the listed conductor specification is 30AWG; the minimum bend radius is 17mm; the stated power consumption is 0.1W; the jacket material is PVC (OFNR).
The rated power consumption is 0.1W. Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.
This assembly uses 30AWG conductors, PVC (OFNR) jacket, minimum bend radius 17mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.
The intended application is 100G Ethernet, 128G Fibre Channel. Listed interface and protocol references include SFPDD: SFP-DD MSA, SFP-DD MIS, IEEE 802.3cdQSFP56: SFF-8661, SFF-8636, IEEE 802.3cd. Confirm that the host firmware and port configuration support the same operating mode.
A passive DAC has no separate optical conversion stage. Its low-power, low-latency operation is useful for short equipment links, but the assembly must remain within the length and signaling mode accepted by both hosts.
At 1m (3ft), C-Z100-Q100-1M is a practical choice for direct connections within one rack. Route the cable along the intended management path rather than pulling it diagonally across adjacent connectors, and leave enough clearance for insertion, removal and front-panel airflow.
C-Z100-Q100-1M is the shortest of 3 verified length options in this family. It is the preferred choice when the port positions are close and cable slack must be kept to a minimum. The next option is C-Z100-Q100-2M at 2m (7ft), adding 1m for a less direct routing path; selecting it unnecessarily would leave more cable to dress.
Specify the OEM part number and fixed length, then provide the intended host configuration if the link uses channelized or breakout ports. Separate part numbers should be used for separate lengths. This gives the compatibility review enough information to check both the physical assembly and the intended operating mode. This page’s fixed configuration is 1m (3ft); another length must be quoted under its corresponding part number.
The verification process combines digital identification with a live link test and diagnostic observation. Host model, hardware revision and software release are useful inputs because qualification behavior can change between platform generations; those details allow platform-specific requirements to be reviewed before the cable is packed. The check includes link stability and diagnostic indications, followed by a final inspection of both ends.
Available stock is generally dispatched within one to three working days after order confirmation, with production lead times advised for larger quantities. Worldwide courier services are available, with air or sea freight for consolidated shipments; freight-collect delivery and coordination with a customer’s logistics provider can be arranged.
Functional inspection covers identification, link establishment and the condition of both connector assemblies. The cable is then protected against dust and connector damage and packed without sharp bends. Labels can include the customer reference and host-platform note when requested for a controlled deployment. Standard protective packing is used by default, with project documentation arranged when requested.
No. It is an HT-manufactured compatible alternative for equipment that specifies Arista C-Z100-Q100-1M.
No. This is one complete direct-attach assembly. The ends are not detachable modules and should not be separated from the cable.
No. Use a supported, bend-safe service loop and observe the listed minimum bend radius. Do not crease the cable or tighten ties around the connector boots.
Not necessarily. Both hosts must support the stated rate, identification, lane mapping and any required breakout configuration; mechanical compatibility alone is insufficient.