Philippines Fiber Optics

Connect the people, connect the world ...

Fiber Optic Cables

Arista CAB-O-4Q-400G-1M Compatible 400G OSFP IHS/Finned Top to 4 x 100G QSFP56 2 x 50G PAM4 Passive Copper Breakout Cable, 1m (3ft)

Arista CAB-O-4Q-400G-1M Compatible 400G OSFP IHS/Finned Top to 4 x 100G QSFP56 2 x 50G PAM4 Passive Copper Breakout Cable, 1m (3ft)

A successful 400G link depends on host acceptance as well as physical fit. This CAB-O-4Q-400G-1M compatible DAC assembly combines OSFP (IHS/Finned Top) to 4x QSFP56 with a fixed 1m (3ft) cable for Arista equipment. The specifications, configuration guidance and live-link factory verification below describe the exact product supplied under this reference.

OEM Part Number: CAB-O-4Q-400G-1MHT Part Number: CAB-O-4Q-400G-1M

Product Highlights

  • Compatible alternative to Arista CAB-O-4Q-400G-1M
  • 400G connectivity at 400Gbps
  • Interface configuration: OSFP (IHS/Finned Top) to 4x QSFP56
  • Fixed length and part number: 1m (3ft), CAB-O-4Q-400G-1M
  • Cable construction: Passive Twinax
  • Conductor specification: 30AWG
  • Maximum power consumption: 0.1W (OSFP End) 0.1W (QSFP56 Per End)
  • Minimum bend radius: 26mm

Specifications

HT Part NumberCAB-O-4Q-400G-1M
Arista Networks CompatibleCAB-O-4Q-400G-1M
ManufacturerHT
Form FactorOSFP (IHS/Finned Top) to 4x QSFP56
Max. Data Rate400Gbps
Cable Length1m (3ft)
Wire AWG30AWG
Minimum Bend Radius26mm
Max. Power Consumption0.1W (OSFP End) 0.1W (QSFP56 Per End)
MediaCopper
Cable TypePassive Twinax
Modulation Format8x 50G-PAM4 to Quad 2x 50G-PAM4
Jacket MaterialPVC (OFNR)
Temperature Range0 to 70°C (32 to 158°F)
ProtocolsOSFP MSA, IEEE 802.3cd, CMIS v4.0

Signal and Lane Configuration

The listed modulation format is 8x 50G-PAM4 to Quad 2x 50G-PAM4. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.

Power and Thermal Planning

The rated power consumption is 0.1W (OSFP End) 0.1W (QSFP56 Per End). Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.

Cable Construction and Routing

This assembly uses 30AWG conductors, PVC (OFNR) jacket, minimum bend radius 26mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.

Network and Protocol Considerations

The intended application is determined by the host interface and protocol support. Listed interface and protocol references include OSFP MSA, IEEE 802.3cd, CMIS v4.0. Confirm that the host firmware and port configuration support the same operating mode.

Breakout Port Mapping

The OSFP (IHS/Finned Top) to 4x QSFP56 configuration divides the high-speed interface into multiple lower-speed connections. Verify the upstream lane assignment, downstream port speeds and breakout setting on the host before connecting the assembly. Each branch must attach to the correct remote interface.

Passive Copper Operation

A passive DAC has no separate optical conversion stage. Its low-power, low-latency operation is useful for short equipment links, but the assembly must remain within the length and signaling mode accepted by both hosts.

Length Selection and Installation Planning

At 1m (3ft), CAB-O-4Q-400G-1M is a practical choice for direct connections within one rack. Route the cable along the intended management path rather than pulling it diagonally across adjacent connectors, and leave enough clearance for insertion, removal and front-panel airflow.

Position Within the Length Range

CAB-O-4Q-400G-1M is the shortest of 3 verified length options in this family. It is the preferred choice when the port positions are close and cable slack must be kept to a minimum. The next option is CAB-O-4Q-400G-2M at 2m (7ft), adding 1m for a less direct routing path; selecting it unnecessarily would leave more cable to dress.

Interoperability and Configuration Checks

Check three layers before deployment: the host must accept the cable identification, the port must support the stated aggregate rate, and the lane configuration must match the attached interfaces. On breakout hardware, also confirm channelization and the mapping of every branch. These checks are particularly important when similar-looking ports operate at different speeds or under different firmware settings. For this assembly, the listed conductor specification is 30AWG; the minimum bend radius is 26mm; the stated power consumption is 0.1W (OSFP End) 0.1W (QSFP56 Per End); the jacket material is PVC (OFNR).

Ordering Information

Specify the OEM part number and fixed length, then provide the intended host configuration if the link uses channelized or breakout ports. Separate part numbers should be used for separate lengths. This gives the compatibility review enough information to check both the physical assembly and the intended operating mode. This page’s fixed configuration is 1m (3ft); another length must be quoted under its corresponding part number.

Arista Compatibility and Factory Testing

The verification process combines digital identification with a live link test and diagnostic observation. Host model, hardware revision and software release are useful inputs because qualification behavior can change between platform generations; those details allow platform-specific requirements to be reviewed before the cable is packed. The check includes link stability and diagnostic indications, followed by a final inspection of both ends.

Shipping and Lead Time

Available stock is generally dispatched within one to three working days after order confirmation, with production lead times advised for larger quantities. Worldwide courier services are available, with air or sea freight for consolidated shipments; freight-collect delivery and coordination with a customer’s logistics provider can be arranged.

Quality Assurance and Packaging

Functional inspection covers identification, link establishment and the condition of both connector assemblies. The cable is then protected against dust and connector damage and packed without sharp bends. Labels can include the customer reference and host-platform note when requested for a controlled deployment. Standard protective packing is used by default, with project documentation arranged when requested.

Frequently Asked Questions

Is this an original Arista cable?

No. It is an HT-manufactured compatible alternative for equipment that specifies Arista CAB-O-4Q-400G-1M.

Does this order code cover multiple lengths?

No. CAB-O-4Q-400G-1M refers here to 1m (3ft). Every other verified length has a separate part number and page in the length list.

Are separate transceivers or patch leads required?

No. This is one complete direct-attach assembly. The ends are not detachable modules and should not be separated from the cable.

Can excess cable be folded into a compact bundle?

No. Use a supported, bend-safe service loop and observe the listed minimum bend radius. Do not crease the cable or tighten ties around the connector boots.


About us