This Arista Networks CAB-S-S-25G compatible cable series provides 25G connectivity through a direct-attach configuration. It is a factory-terminated passive twinax link without separate optical modules or patch cords. The page brings together the series specifications, compatibility guidance and direct links to the individual length and OEM part-number pages used for ordering.
Series Part Number: CAB-S-S-25GHT Part Number: CAB-S-S-25G
The documented configurations are 1m (3ft), 1.5m (5ft), 2m (7ft), 2.5m (8ft), 3m (10ft), 4m (13ft) and 5m (16ft). Each link below opens the separate product page for that physical length and its corresponding OEM part number. Select the exact assembly required by the route and purchase order; custom project lengths can be discussed separately.
| Arista Networks Compatible | CAB-S-S-25G-1M |
|---|---|
| Manufacturer | HT |
| HT Part Number | CAB-S-S-25G |
| Connector Type | SFP28 to SFP28 |
| Max Data Rate | 25Gbps |
| Minimum Bend Radius | 21.25mm |
| Wire AWG | 30AWG |
| Cable Length Options Covered | 1m (3ft), 1.5m (5ft), 2m (7ft), 2.5m (8ft), 3m (10ft), 4m (13ft) and 5m (16ft) |
| Jacket Material | PVC (OFNR) |
| Typical Power Consumption | ≤0.5W |
| Power Supply | 3.3V |
| Temperature | 0 to 70°C (32 to 158°F) |
| Protocols | IEEE 802.3, SFP28 MSA, SFF-8402, Infiniband, EIA 364-1000 |
| Application | 25G Ethernet, Data Center, 5G Wireless |
Passive twinax cables are commonly selected for short switch-to-switch, switch-to-server and accelerator connections within or between nearby racks. With no separate optical conversion stage, they offer a simple low-power physical link. The assembly must nevertheless remain within the length, signaling rate and qualification limits accepted by both hosts. For this series, the listed interface is the stated interface and the aggregate rate is 25G. The stated application is 25G Ethernet, Data Center, 5G Wireless.
The verification process combines digital identification with a live link test and diagnostic observation. Host model, hardware revision and software release are useful inputs because qualification behavior can change between platform generations; those details allow platform-specific requirements to be reviewed before the cable is packed. Series-level inspection is followed by the exact length and OEM configuration selected for dispatch. Functional verification includes link establishment and diagnostic indications where the host exposes them.
For this assembly, the conductor specification is 30AWG; the jacket material is PVC (OFNR); the minimum bend radius is 21.25mm. These parameters belong in the installation review rather than being treated as catalogue trivia. Route the cable through its intended managers without tension, avoid pressure close to the connector boots and leave enough space to operate the latches. Any service loop must respect the stated bend limit.
Check three layers before deployment: the host must accept the cable identification, the port must support the stated aggregate rate, and the lane configuration must match the attached interfaces. On breakout hardware, also confirm channelization and the mapping of every branch. These checks are particularly important when similar-looking ports operate at different speeds or under different firmware settings. For this series, keep the interface rate, DAC construction and length-specific OEM reference together throughout that review.
Specify the OEM part number and fixed length, then provide the intended host configuration if the link uses channelized or breakout ports. Separate part numbers should be used for separate lengths. This gives the compatibility review enough information to check both the physical assembly and the intended operating mode. For this series, follow the corresponding length link, quote that exact OEM part number and keep different lengths on separate order lines. HT part number CAB-S-S-25G identifies the product family; the linked page provides the final length-specific identity.
Standard configurations normally ship within one to three working days, with production lead times confirmed for larger quantities. International courier, air freight and sea freight are available; customer courier accounts and nominated forwarders are accepted.
Functional inspection covers identification, link establishment and the condition of both connector assemblies. The cable is then protected against dust and connector damage and packed without sharp bends. Labels can include the customer reference and host-platform note when requested for a controlled deployment. Both connector ends are inspected as part of the complete assembly, and protective packing is selected to avoid tight bends during transport and storage.
No. It is an HT-manufactured compatible cable for equipment that specifies CAB-S-S-25G, not an original Arista Networks-branded product.
Yes. Where a length has its own OEM reference, follow the corresponding link above and order that exact part number on its own line. Do not substitute another length only because the connector arrangement is the same.
No. The connector ends and cable form one complete direct-attach assembly. The ends are not detachable standalone transceivers, and the complete product is tested together.
Provide the equipment manufacturer and model, port type, hardware revision and software release, together with the required OEM reference, length and quantity. Breakout projects should also identify the intended lane configuration.