Philippines Fiber Optics

Connect the people, connect the world ...

Fiber Optic Cables

Fortinet FN-CABLE-QSFP28-4SFP28-1.5 Compatible 100G QSFP28 4 x 25G NRZ to 4 x 25G SFP28 NRZ Passive Copper Breakout Cable, 1.5m (5ft)

Fortinet FN-CABLE-QSFP28-4SFP28-1.5 Compatible 100G QSFP28 4 x 25G NRZ to 4 x 25G SFP28 NRZ Passive Copper Breakout Cable, 1.5m (5ft)

A successful 100G link depends on host acceptance as well as physical fit. This FN-CABLE-QSFP28-4SFP28-1.5 compatible DAC assembly combines QSFP28 to SFP28 with a fixed 1.5m (5ft) cable for Fortinet equipment. The specifications, configuration guidance and live-link factory verification below describe the exact product supplied under this reference.

OEM Part Number: FN-CABLE-QSFP28-4SFP28-1.5HT Part Number: FN-CABLE-QSFP28-4SFP28-1.5

Product Highlights

  • Compatible alternative to Fortinet FN-CABLE-QSFP28-4SFP28-1.5
  • 100G connectivity at 100Gbps
  • Interface configuration: QSFP28 to SFP28
  • Fixed length and part number: 1.5m (5ft), FN-CABLE-QSFP28-4SFP28-1.5
  • Cable construction: Passive Twinax
  • Conductor specification: 30AWG
  • Maximum power consumption: ≤0.125W
  • Minimum bend radius: 60mm

Specifications

HT Part NumberFN-CABLE-QSFP28-4SFP28-1.5
Fortinet CompatibleFN-CABLE-QSFP28-4SFP28-1.5
ManufacturerHT
Form FactorQSFP28 to SFP28
Max Data Rate100Gbps
Cable TypePassive Twinax
Cable Length1.5m (5ft)
Wire AWG30AWG
Minimum Bend Radius60mm
Power Consumption≤0.125W
Power Supply3.3V
MTBF=50 Million Hours
Jacket MaterialPVC (OFNR)
Commercial Temperature Range0 to 70°C (32 to 158°F)
Modulation FormatQSFP28-4x 25G-NRZ SFP28-1x 25G-NRZ
MediaCopper
Application100G to 4x 25G Ethernet, Data Centers
ProtocolsIEEE 802.3, QSFP28 MSA, SFF-8665

Signal and Lane Configuration

The listed modulation format is QSFP28-4x 25G-NRZ SFP28-1x 25G-NRZ. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.

Breakout Port Mapping

The QSFP28 to SFP28 configuration divides the high-speed interface into multiple lower-speed connections. Verify the upstream lane assignment, downstream port speeds and breakout setting on the host before connecting the assembly. Each branch must attach to the correct remote interface.

Passive Copper Operation

A passive DAC has no separate optical conversion stage. Its low-power, low-latency operation is useful for short equipment links, but the assembly must remain within the length and signaling mode accepted by both hosts.

Length Selection and Installation Planning

The additional half metre beyond a one-metre assembly gives FN-CABLE-QSFP28-4SFP28-1.5 useful routing flexibility when the ports are not directly aligned. It can accommodate a different rack unit or a short service loop, but excess cable should be dressed loosely rather than folded into a tight coil.

Position Within the Length Range

FN-CABLE-QSFP28-4SFP28-1.5 occupies the middle of this family between FN-CABLE-QSFP28-4SFP28-1 at 1m (3ft) and FN-CABLE-QSFP28-4SFP28-2 at 2m (7ft). It adds 0.5m over the shorter option for extra routing clearance, while the next longer version adds another 0.5m. Measure the managed path and choose this version when its reach is sufficient without creating the slack associated with the longer assembly.

Interoperability and Configuration Checks

Check three layers before deployment: the host must accept the cable identification, the port must support the stated aggregate rate, and the lane configuration must match the attached interfaces. On breakout hardware, also confirm channelization and the mapping of every branch. These checks are particularly important when similar-looking ports operate at different speeds or under different firmware settings. For this assembly, the listed conductor specification is 30AWG; the minimum bend radius is 60mm; the stated power consumption is ≤0.125W; the jacket material is PVC (OFNR).

Power and Thermal Planning

The rated power consumption is ≤0.125W. Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.

Cable Construction and Routing

This assembly uses 30AWG conductors, PVC (OFNR) jacket, minimum bend radius 60mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.

Network and Protocol Considerations

The intended application is 100G to 4x 25G Ethernet, Data Centers. Listed interface and protocol references include IEEE 802.3, QSFP28 MSA, SFF-8665. Confirm that the host firmware and port configuration support the same operating mode.

Ordering Information

Specify the OEM part number and fixed length, then provide the intended host configuration if the link uses channelized or breakout ports. Separate part numbers should be used for separate lengths. This gives the compatibility review enough information to check both the physical assembly and the intended operating mode. Quantity and any labeling instructions should be attached specifically to FN-CABLE-QSFP28-4SFP28-1.5.

Fortinet Compatibility and Factory Testing

The verification process combines digital identification with a live link test and diagnostic observation. Host model, hardware revision and software release are useful inputs because qualification behavior can change between platform generations; those details allow platform-specific requirements to be reviewed before the cable is packed. Where supported by the host, link stability and diagnostic indications are reviewed together with the established link.

Shipping and Lead Time

Standard configurations normally ship within one to three working days, while production quantities are confirmed with the order. Delivery can be arranged by courier, air freight or sea freight, and goods may instead be handed to an appointed forwarder or shipped on the customer’s courier account.

Quality Assurance and Packaging

Functional inspection covers identification, link establishment and the condition of both connector assemblies. The cable is then protected against dust and connector damage and packed without sharp bends. Labels can include the customer reference and host-platform note when requested for a controlled deployment. Neutral packaging and customer-specific packing documentation are available on request.

Frequently Asked Questions

Is this an original Fortinet cable?

No. It is an HT-manufactured compatible alternative for equipment that specifies Fortinet FN-CABLE-QSFP28-4SFP28-1.5.

Are separate transceivers or patch leads required?

No. This is one complete direct-attach assembly. The ends are not detachable modules and should not be separated from the cable.

Can excess cable be folded into a compact bundle?

No. Use a supported, bend-safe service loop and observe the listed minimum bend radius. Do not crease the cable or tighten ties around the connector boots.

Will any matching connector operate at the same speed?

Not necessarily. Both hosts must support the stated rate, identification, lane mapping and any required breakout configuration; mechanical compatibility alone is insufficient.


About us

China Factory:No 168 Golden Ground Industrial Area;
Philippines Address:Makati City,Metro Manila, Philippines

Products catalogues

For products catalogue/data sheets or any general inquiry, please email info@huihongfiber.com and we will reply with details.

Customer Support

For customer support, please email sales@huihongfiber.com; our support team will get back to you as soon as possible.