Projects in the Philippines benefit from keeping the configuration, branch identification and installation requirement consistent across every participating site. This duplex FTTA patch cable connects the baseband unit at the foot of the tower to the remote radio unit at the top, carrying two OS2 9/125µm single-mode fibers inside a 7.0mm LSZH outdoor jacket. Both cable ends terminate in LC UPC duplex connectors that plug directly into the SFP and SFP+ ports of common LTE, 4G and 5G radio systems. The fiber cable core is Corning G.657.A1 bend-insensitive glass, and each individual leg is protected by a helical steel armored branch tube; as a result, the factory-built assembly survives pulling, bird damage and rodents across years of outdoor exposure.
| Connector Type | LC to LC |
|---|---|
| Polish Type | UPC to UPC |
| Fiber Mode | OS2 9/125µm |
| Wavelength | 1310/1550nm |
| Fiber Count | Duplex / 2 Fibers |
| Fiber Grade | Corning G.657.A1 |
| Min. Bend Radius (Fiber Cable) | 20/10D (Dynamic/Static) |
| Attenuation at 1310nm | ≤0.36dB/km |
| Attenuation at 1550nm | ≤0.22dB/km |
| Cable Jacket | Low Smoke Zero Halogen (LSZH) |
| Cable Diameter (Outer/Inner) | 7.0/2.0mm |
| Armored Breakout Length (End A/B) | 0.03/0.34m (0.2m optional) |
| Tensile Strength | 200/400N (Long/Short Term) |
| Crush Resistance | 1100/2200N (Long/Short Term) |
| Insertion Loss | ≤0.3dB |
| Return Loss | ≥50dB |
| Operating Temperature | -20 to 70°C (-4 to 158°F) |
| Storage Temperature | -40 to 80°C (-40 to 176°F) |
Modern base station architecture separates the baseband unit (BBU) in the shelter or cabinet from the remote radio unit (RRU) mounted beside the antenna. The optical path between them carries CPRI or eCPRI traffic over duplex single-mode fiber, and it is the most mechanically stressed jumper in the network: it hangs vertically on the tower, flexes in the wind, and is exposed to ultraviolet radiation, rain and temperature cycling every day of its service life. This fiber cable is engineered for exactly that run, with a jacket and strength configuration rated for outdoor deployment rather than adapted from an indoor patch cord.
The last meters of an FTTA run are the most vulnerable. Where this backbone cable breaks out into legs at the RRU end, standard 2.0mm tails may readily be crushed by clamps, chewed by rodents or pecked open by birds. Each individual leg of this factory-built assembly is sleeved in a helical stainless steel tube that keeps the branch flexible while adding real crush and bite resistance. The breakout point is potted and strain-relieved; as a result, tower vibration and handling loads never reach the ferrule end-faces.
Cable routing on a monopole or lattice tower rarely allows generous sweep bends. G.657.A1 bend-insensitive fiber tolerates a 10D static and 20D dynamic bend radius; as a result, the fiber cable may readily be dressed through cable glands, tight tray entries and the crowded junction box at the tower base without adding macrobend loss. The glass remains fully compatible with legacy G.652.D single-mode plant, which keeps the optical path optical budget unchanged when this patch cord connects into older feeder fiber.
Several FTTA runs start inside an equipment shelter, pass through a wall gland and continue outdoors up the tower. A single cable that is legal for both zones simplifies the bill of materials: the low smoke zero halogen jacket meets indoor fire expectations while its UV-stabilized, chemically resistant compound handles years of outdoor exposure. There is no transition point, no extra enclosure, and one less splice in the power budget.
Standard size options are stocked for fast delivery: 1m (3ft), 2m (7ft), 3m (10ft), 5m (16ft), 10m (33ft), 20m (66ft), 30m (98ft) and 50m (164ft), covering the common shelter-to-tower and frame-to-radio runs this cord is built for. Non-standard lengths beyond this range are manufactured to order. For tower runs, measure the channel from the BBU patching field to the RRU port with the fiber cable tray optical route included, then add working slack at both cable ends; an accurately ordered length avoids a service loop hanging on the structure. Specifying the particular channel length avoids both the slack storage problem of an overlong cord and the strain risk of one that is too short.
Each completed assembly is terminated with precision zirconia ferrule connectors and optically tested before packing: insertion loss is verified against the 0.3dB ceiling and return loss against the 50dB minimum on each individual leg, not on a sample basis. End-face geometry is inspected for consistent physical contact, and the fiber cable is proof-checked so that the delivered jumper may readily be plugged in and put into service without on-site rework.
Refer to the LC-LC duplex FTTA product line when submitting a request for a quotation and state the channel length and the breakout style applicable at the RRU end. For connector mixes other than LC to LC, or for non-standard breakout lengths, the customized FTTA program covers the equivalent cable platform; send the need with the inquiry and the factory will validate the manufacturable specification before release to production. Customers in the Philippines can include multi-site labeling or documentation requirements when requesting a project quotation.