LC/SC/FC/ST/LSH Single Mode Fixed Fiber Optic Attenuator, Female to Female, 3-15dB

LC/SC/FC/ST/LSH Single Mode Fixed Fiber Optic Attenuator, Female to Female, 3-15dB

Projects in the Philippines benefit from keeping the configuration, branch identification and installation requirement consistent across every participating site. LC/SC/FC/ST/LSH Single Mode Fixed Fiber Optic Attenuator inserts a precisely calibrated fixed loss into a fiber optical path. The attenuating element is ion-doped fiber - the loss is spectrally flat and reflection-free, unlike air-gap or offset designs - so the optical path sees exactly the rated attenuation at every operating wavelength. The female-to-female body works inline between two standard patch patch leads, adding attenuation without disturbing the connector interface plan of the plant.

Product Highlights

  • Attenuating Material-ion Doped Fiber
  • 1260 to 1620nm Wavelength Singlemode Attenuators
  • Available in a Variety of Connector Types
  • Standard Fixed Attenuation Values of 3/5/7/10/15dB
  • Applied for CWDM, DWDM, Test Equipment, CATV Systems, Point to Point Systems, etc.

Specifications

Connector GenderFixed Female to Female
Attenuation3/5/7/10/15dB
Operating Wavelength(nm)1260~1620(SM)
Operating Temperature Range-25 to 70°C (-13 to 158°F)
Storage Temperature Range-40 to 85°C (-40 to 185°F)
Application(1)Length(1)

Available Attenuation Values

This female-to-female attenuator is stocked in the standard inline values: 3dB, 5dB, 7dB, 10dB, 15dB. Each value is individually calibrated and marked on the housing.

3dB   5dB   7dB   10dB   15dB

Why links need attenuation at all

Optical links are engineered with a power budget: the transmitter launches, the fiber and connectors consume, and the receiver expects what remains inside a defined window. Short routes, dense wavelength plans and high-power transmitters may all deliver too much light, and an overloaded receiver distorts exactly like an overloaded amplifier - errors appear on an optical path that tests perfectly on loss alone. A fixed attenuator brings the received power back inside the window, and the optical path behaves as designed.

Ion-doped fiber as the attenuating element

The cleanest way to attenuate light is to absorb it inside the fiber itself. Ion-doped fiber attenuators do exactly that: a short section of doped glass absorbs a calibrated fraction of the optical power and converts it to negligible heat. Because the attenuation happens inside the core, the light that emerges keeps its mode profile and the device adds virtually no reflectance. The alternatives - air gaps, offsets and misaligned ferrules - all trade loss against reflections and modal noise, which is why precision attenuators abandoned them. Project teams in the Philippines can carry this requirement into the site documentation used by each contractor.

Choosing the attenuation value

The right specification is the difference between what the optical path delivers and what the receiver wants, plus a small margin. Measure or calculate the expected receive power first; then determine the nearest standard specification - 1, 2, 3, 5, 7, 10, 15, 20 or 25 dB - that lands the receiver inside its window. Too little attenuation leaves the receiver overloaded; too much eats the margin that aging and repairs will need later. When the need sits between standard values, the customized platform covers the particular figure.

Fixed values versus a variable instrument

Fixed attenuators win on stability, size and price: once the applicable loss is known, a fixed device holds it permanently with no moving parts. Variable attenuators win when the loss itself is the question - receiver sensitivity testing, margin surveys, multi-wavelength leveling - where sweeping the specification is the whole point. Most plants need both: fixed units installed in the links, and a variable instrument in the test kit.

Female-to-female inline attenuators

The female-to-female body sits between two standard patch patch leads like a coupler with a calibrated loss. That format suits test setups and temporary installations where the attenuator moves between links, and plants where the connector interface plan is fixed and the attenuation should be added inline. Either way, the attenuation specification, not the gender, is what the optical path sees.

Return loss and the polish discipline

An attenuator sits in the middle of the optical path; as a result, its reflectance counts twice - once toward the transmitter and once toward the receiver. UPC versions hold return loss at 50 dB or better, and APC versions at 60 dB or better, which keeps reflected power far below anything a modern transmitter notices. The polish grade must align with the plant: an APC attenuator mated to a UPC connector through an adapter damages both end faces and destroys the very return loss it was selected to protect.

Handling and cleaning attenuators

An attenuator is a connector with optics inside, and connector rules apply: keep the caps on until the moment of mating, clean every end face before insertion, and never mate a contaminated ferrule into the device - the dirt transfers to the attenuator end face and the next connector that touches it. Store spare units capped and bagged, and record which optical path each installed unit serves so replacement orders match the original specification.

Selecting the right attenuator

Four decisions define the order: the attenuation specification must align with the optical path calculation, the connector interface product line must align with the port or the patch leads, the polish grade must align with the plant, and the body style - plug or inline - must suit the deployment. Fixed values cover permanent installations; the variable instruments cover testing; the test cable covers transceiver qualification. Getting all four right at order time is what turns a small component into a dependable part of the optical path.

Production Testing and Quality Assurance

Every attenuator is optically verified before packing: the attenuation specification is measured at the operating wavelengths and checked against its rated tolerance, return loss is verified to its polish grade, and the connector interface end faces are inspected for scratches and contamination. Units ship capped and bagged.

Placing an Order and Factory Support

Refer to this attenuator by attenuation specification, connector product line, polish grade and body style when submitting a request for a quotation. For values or configurations outside the listed options - non-standard dB figures, mixed connector pairings or project packaging - send the need with the inquiry and the factory will validate the manufacturable specification. Customers in the Philippines can include multi-site labeling or documentation requirements when requesting a project quotation.

 

About us

China Factory:No 168 Golden Ground Industrial Area;
Philippines Address:Makati City,Metro Manila, Philippines

Products catalogues

For products catalogue/data sheets or any general inquiry, please email info@huihongfiber.com and we will reply with details.

Customer Support

For customer support, please email sales@huihongfiber.com; our support team will get back to you as soon as possible.