Philippines Fiber Optics

Connect the people, connect the world ...

Fiber Optic Cables

NVIDIA/Mellanox MCA4J80-N003 Compatible 800G Twin-port OSFP 8 x 100G PAM4 IHS/Finned Top Ethernet Active Copper Twinax Cable, 3m (10ft)

NVIDIA/Mellanox MCA4J80-N003 Compatible 800G Twin-port OSFP 8 x 100G PAM4 IHS/Finned Top Ethernet Active Copper Twinax Cable, 3m (10ft)

Use this 3m (10ft) ACC cable for hosts expecting NVIDIA/Mellanox MCA4J80-N003 and a 800G direct-attached interface. The assembly uses OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top); lane, protocol and breakout considerations are documented alongside the verified table. Every alternative length remains a separate order code with its own technical page.

OEM Part Number: MCA4J80-N003HT Part Number: MCA4J80-N003

Product Highlights

  • Compatible alternative to NVIDIA/Mellanox MCA4J80-N003
  • 800G connectivity at 850Gbps (8x 106.25Gbps)
  • Interface configuration: OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)
  • Fixed length and part number: 3m (10ft), MCA4J80-N003
  • Cable construction: Active DAC (ACC)
  • Conductor specification: 30AWG
  • Maximum power consumption: 1.3W Per End
  • Minimum bend radius: 48.5mm

Specifications

HT Part NumberMCA4J80-N003
NVIDIA/Mellanox Ethernet CompatibleMCA4J80-N003
ManufacturerHT
Form FactorOSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)
Max. Data Rate850Gbps (8x 106.25Gbps)
MediaCopper
Cable TypeActive DAC (ACC)
Cable Length3m (10ft)
Wire AWG30AWG
Minimum Bend Radius48.5mm
Max. Power Consumption1.3W Per End
Jacket MaterialPET
Commercial Temperature Range0 to 70°C (32 to 158°F)
Modulation Format8x100G-PAM4
Application800G Ethernet
ProtocolsCMIS 5.0, IEEE 802.3ck, OSFP Rev5.0

Signal and Lane Configuration

The listed modulation format is 8x100G-PAM4. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.

Interoperability and Configuration Checks

Check three layers before deployment: the host must accept the cable identification, the port must support the stated aggregate rate, and the lane configuration must match the attached interfaces. On breakout hardware, also confirm channelization and the mapping of every branch. These checks are particularly important when similar-looking ports operate at different speeds or under different firmware settings. For this assembly, the listed conductor specification is 30AWG; the minimum bend radius is 48.5mm; the stated power consumption is 1.3W Per End; the jacket material is PET.

Power and Thermal Planning

The rated power consumption is 1.3W Per End. Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.

Cable Construction and Routing

This assembly uses 30AWG conductors, PET jacket, minimum bend radius 48.5mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.

Network and Protocol Considerations

The intended application is 800G Ethernet. Listed interface and protocol references include CMIS 5.0, IEEE 802.3ck, OSFP Rev5.0. Confirm that the host firmware and port configuration support the same operating mode.

Length Selection and Installation Planning

At 3m (10ft), this assembly can bridge non-aligned ports or adjacent racks while remaining a single direct-attach link. Support longer horizontal runs with suitable cable management and preserve space for cooling and future maintenance.

Position Within the Length Range

MCA4J80-N003 is the longest of 2 verified length options in this family. Compared with MCA4J80-N001 at 1m (3ft), it provides 2m of additional reach for a longer vertical drop, a wider rack or an adjacent-cabinet route. Confirm that the complete path requires this length, because unused slack still needs supported, bend-safe storage.

Ordering Information

Specify the OEM part number and fixed length, then provide the intended host configuration if the link uses channelized or breakout ports. Separate part numbers should be used for separate lengths. This gives the compatibility review enough information to check both the physical assembly and the intended operating mode. This page’s fixed configuration is 3m (10ft); another length must be quoted under its corresponding part number.

NVIDIA/Mellanox Compatibility and Factory Testing

The verification process combines digital identification with a live link test and diagnostic observation. Host model, hardware revision and software release are useful inputs because qualification behavior can change between platform generations; those details allow platform-specific requirements to be reviewed before the cable is packed. The check includes link stability and diagnostic indications, followed by a final inspection of both ends.

Shipping and Lead Time

Standard configurations normally ship within one to three working days, while production quantities are confirmed with the order. Delivery can be arranged by courier, air freight or sea freight, and goods may instead be handed to an appointed forwarder or shipped on the customer’s courier account.

Quality Assurance and Packaging

Functional inspection covers identification, link establishment and the condition of both connector assemblies. The cable is then protected against dust and connector damage and packed without sharp bends. Labels can include the customer reference and host-platform note when requested for a controlled deployment. Neutral packaging and customer-specific packing documentation are available on request.

Frequently Asked Questions

Is this an original NVIDIA/Mellanox cable?

No. It is an HT-manufactured compatible alternative for equipment that specifies NVIDIA/Mellanox MCA4J80-N003.

Does this order code cover multiple lengths?

No. MCA4J80-N003 refers here to 3m (10ft). Every other verified length has a separate part number and page in the length list.

Are separate transceivers or patch leads required?

No. This is one complete direct-attach assembly. The ends are not detachable modules and should not be separated from the cable.

Can excess cable be folded into a compact bundle?

No. Use a supported, bend-safe service loop and observe the listed minimum bend radius. Do not crease the cable or tighten ties around the connector boots.


About us

China Factory:No 168 Golden Ground Industrial Area;
Philippines Address:Makati City,Metro Manila, Philippines

Products catalogues

For products catalogue/data sheets or any general inquiry, please email info@huihongfiber.com and we will reply with details.

Customer Support

For customer support, please email sales@huihongfiber.com; our support team will get back to you as soon as possible.