
A successful 100G link depends on host acceptance as well as physical fit. This MFA7A20-C050 compatible AOC assembly combines QSFP28 to 2x QSFP28 with a fixed 50m (164ft) cable for NVIDIA/Mellanox equipment. The specifications, configuration guidance and live-link factory verification below describe the exact product supplied under this reference.
OEM Part Number: MFA7A20-C050HT Part Number: MFA7A20-C050
| HT Part Number | MFA7A20-C050 |
|---|---|
| NVIDIA/Mellanox Ethernet Compatible | MFA7A20-C050 |
| Manufacturer | HT |
| Form Factor | QSFP28 to 2x QSFP28 |
| Max. Data Rate | 100Gbps |
| Cable Length | 50m (164ft) |
| Cable Type | Breakout AOC |
| Wavelength | 850nm |
| Minimum Bend Radius | 30mm |
| Transmitter Type | VSCEL |
| Receiver Type | PIN |
| Max. Power Consumption | 2.2W (100G Per End)1.5W (50G Per End) |
| Modulation Format | 4x 25G-NRZ to 2x 25G-NRZ |
| CDR (Clock and Data Recovery) | TX & RX Built-in CDR |
| Jacket Material | OFNP |
| DDM/DOM | Supported |
| Commercial Temperature Range | 0 to 70°C (32 to 158°F) |
| Protocols | QSFP28 Electrical MSA, SFF-8636, SFF-8665 |
The listed modulation format is 4x 25G-NRZ to 2x 25G-NRZ. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.
The optical engines and fiber are permanently integrated into this AOC. There are no detachable optical modules to clean or exchange. Handle the complete assembly by its connector housings and cable, and keep both ends matched to the same interface specification.
The extended 50m (164ft) configuration gives MFA7A20-C050 a specific place in the family reach range. It should not be treated as a universal substitute for every shorter order code. Match it to a documented route, protect the integrated optical cable and both optical engines during handling and retain the part-number label for later maintenance. Within this family, MFA7A20-C030 is shorter at 30m (98ft), while MFA7A20-C070 is the next longer choice at 70m (230ft); comparing those two boundaries helps avoid both tension and unnecessary slack.
MFA7A20-C050 occupies the middle of this family between MFA7A20-C030 at 30m (98ft) and MFA7A20-C070 at 70m (230ft). It adds 20m over the shorter option for extra routing clearance, while the next longer version adds another 20m. Measure the managed path and choose this version when its reach is sufficient without creating the slack associated with the longer assembly.
Check three layers before deployment: the host must accept the cable identification, the port must support the stated aggregate rate, and the lane configuration must match the attached interfaces. On breakout hardware, also confirm channelization and the mapping of every branch. These checks are particularly important when similar-looking ports operate at different speeds or under different firmware settings. For this assembly, the minimum bend radius is 30mm; the stated power consumption is 2.2W (100G Per End)1.5W (50G Per End); the jacket material is OFNP.
The rated power consumption is 2.2W (100G Per End)1.5W (50G Per End). Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.
This assembly uses OFNP jacket, minimum bend radius 30mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.
The intended application is determined by the host interface and protocol support. Listed interface and protocol references include QSFP28 Electrical MSA, SFF-8636, SFF-8665. Confirm that the host firmware and port configuration support the same operating mode.
The QSFP28 to 2x QSFP28 configuration divides the high-speed interface into multiple lower-speed connections. Verify the upstream lane assignment, downstream port speeds and breakout setting on the host before connecting the assembly. Each branch must attach to the correct remote interface.
Specify the OEM part number and fixed length, then provide the intended host configuration if the link uses channelized or breakout ports. Separate part numbers should be used for separate lengths. This gives the compatibility review enough information to check both the physical assembly and the intended operating mode. Quantity and any labeling instructions should be attached specifically to MFA7A20-C050.
The verification process combines digital identification with a live link test and diagnostic observation. Host model, hardware revision and software release are useful inputs because qualification behavior can change between platform generations; those details allow platform-specific requirements to be reviewed before the cable is packed. The check includes receive activity and diagnostic indications, followed by a final inspection of both ends.
Standard configurations normally ship within one to three working days, while production quantities are confirmed with the order. Worldwide courier services are available, with air or sea freight for consolidated shipments; freight-collect delivery and coordination with a customer’s logistics provider can be arranged.
Functional inspection covers identification, link establishment and the condition of both connector assemblies. The cable is then protected against dust and connector damage and packed without sharp bends. Labels can include the customer reference and host-platform note when requested for a controlled deployment. Neutral packaging and customer-specific packing documentation are available on request.
No. It is an HT-manufactured compatible alternative for equipment that specifies NVIDIA/Mellanox MFA7A20-C050.
Only where both hosts explicitly support the complete interface and compatibility arrangement. Document each end and select the appropriate brand-specific product when required.
No. MFA7A20-C050 refers here to 50m (164ft). Every other verified length has a separate part number and page in the length list.
No. This is one complete direct-attach assembly. The ends are not detachable modules and should not be separated from the cable.