Philippines Fiber Optics

Connect the people, connect the world ...

Fiber Optic Cables

NVIDIA/Mellanox MFA7U10-H015-FLT Compatible 400G OSFP 8 x 50G PAM4 RHS/Flat Top to 2 x 200G QSFP56 4 x 50G PAM4 InfiniBand HDR Active Optical Breakout Cable, 15m (49ft)

NVIDIA/Mellanox MFA7U10-H015-FLT Compatible 400G OSFP 8 x 50G PAM4 RHS/Flat Top to 2 x 200G QSFP56 4 x 50G PAM4 InfiniBand HDR Active Optical Breakout Cable, 15m (49ft)

The MFA7U10-H015-FLT compatible assembly addresses a specific interoperability requirement: NVIDIA/Mellanox host identification on a 400G AOC link measuring 15m (49ft). Its interface configuration is OSFP (RHS/Flat Top) to 2x QSFP56. This page explains the physical product, port-configuration checks and related part numbers so selection does not rely on connector appearance alone.

OEM Part Number: MFA7U10-H015-FLTHT Part Number: MFA7U10-H015-FLT

Product Highlights

  • Compatible alternative to NVIDIA/Mellanox MFA7U10-H015-FLT
  • 400G connectivity at 400Gbps
  • Interface configuration: OSFP (RHS/Flat Top) to 2x QSFP56
  • Fixed length and part number: 15m (49ft), MFA7U10-H015-FLT
  • Cable construction: Breakout AOC
  • Maximum power consumption: 10W (OSFP End) 5.5W (QSFP56 Per End)
  • Minimum bend radius: 30mm
  • Operating temperature: 0 to 70°C (32 to 158°F)

Specifications

HT Part NumberMFA7U10-H015-FLT
NVIDIA/Mellanox InfiniBand CompatibleMFA7U10-H015-FLT
ManufacturerHT
Form FactorOSFP (RHS/Flat Top) to 2x QSFP56
Max. Data Rate400Gbps
Cable Length15m (49ft)
Cable TypeBreakout AOC
Wavelength850nm
Minimum Bend Radius30mm
Transmitter TypeVSCEL
Receiver TypePIN
Max. Power Consumption10W (OSFP End) 5.5W (QSFP56 Per End)
Jacket MaterialOFNP
CDR (Clock and Data Recovery)TX & RX Built-in CDR
Modulation Format8x 50G-PAM4 to Dual 4x 50G-PAM4
DDM/DOMSupported
Commercial Temperature Range0 to 70°C (32 to 158°F)
ProtocolsCMIS 4.0, SFF-8636,IEEE 802.3 bs-2*200GAUI-4, IEEE 802.3 bs-200GAUI-4, OSFP MSA, SFF-8679, SFF-8661

Signal and Lane Configuration

The listed modulation format is 8x 50G-PAM4 to Dual 4x 50G-PAM4. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.

Breakout Port Mapping

The OSFP (RHS/Flat Top) to 2x QSFP56 configuration divides the high-speed interface into multiple lower-speed connections. Verify the upstream lane assignment, downstream port speeds and breakout setting on the host before connecting the assembly. Each branch must attach to the correct remote interface.

Integrated Optical Assembly

The optical engines and fiber are permanently integrated into this AOC. There are no detachable optical modules to clean or exchange. Handle the complete assembly by its connector housings and cable, and keep both ends matched to the same interface specification.

Length Selection and Installation Planning

The installation review for a 15m (49ft) link should include pathway length, support points, connector access and future maintenance. Route the integrated optical cable and both optical engines before attaching both ends, and avoid dragging it across connector panels. A final inspection should confirm that no latch, boot or jacket section carries unnecessary strain. Within this family, MFA7U10-H010-FLT is shorter at 10m (33ft), while MFA7U10-H020-FLT is the next longer choice at 20m (66ft); comparing those two boundaries helps avoid both tension and unnecessary slack.

Position Within the Length Range

MFA7U10-H015-FLT occupies the middle of this family between MFA7U10-H010-FLT at 10m (33ft) and MFA7U10-H020-FLT at 20m (66ft). It adds 5m over the shorter option for extra routing clearance, while the next longer version adds another 5m. Measure the managed path and choose this version when its reach is sufficient without creating the slack associated with the longer assembly.

Interoperability and Configuration Checks

Check three layers before deployment: the host must accept the cable identification, the port must support the stated aggregate rate, and the lane configuration must match the attached interfaces. On breakout hardware, also confirm channelization and the mapping of every branch. These checks are particularly important when similar-looking ports operate at different speeds or under different firmware settings. For this assembly, the minimum bend radius is 30mm; the stated power consumption is 10W (OSFP End) 5.5W (QSFP56 Per End); the jacket material is OFNP.

Power and Thermal Planning

The rated power consumption is 10W (OSFP End) 5.5W (QSFP56 Per End). Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.

Cable Construction and Routing

This assembly uses OFNP jacket, minimum bend radius 30mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.

Network and Protocol Considerations

The intended application is determined by the host interface and protocol support. Listed interface and protocol references include CMIS 4.0, SFF-8636,IEEE 802.3 bs-2*200GAUI-4, IEEE 802.3 bs-200GAUI-4, OSFP MSA, SFF-8679, SFF-8661. Confirm that the host firmware and port configuration support the same operating mode.

Ordering Information

Specify the OEM part number and fixed length, then provide the intended host configuration if the link uses channelized or breakout ports. Separate part numbers should be used for separate lengths. This gives the compatibility review enough information to check both the physical assembly and the intended operating mode. Keep MFA7U10-H015-FLT associated with 15m (49ft) throughout the order and receiving record.

NVIDIA/Mellanox Compatibility and Factory Testing

The verification process combines digital identification with a live link test and diagnostic observation. Host model, hardware revision and software release are useful inputs because qualification behavior can change between platform generations; those details allow platform-specific requirements to be reviewed before the cable is packed. Where supported by the host, receive activity and diagnostic indications are reviewed together with the established link.

Shipping and Lead Time

Standard configurations normally ship within one to three working days, while production quantities are confirmed with the order. Delivery can be arranged by courier, air freight or sea freight, and goods may instead be handed to an appointed forwarder or shipped on the customer’s courier account.

Quality Assurance and Packaging

Functional inspection covers identification, link establishment and the condition of both connector assemblies. The cable is then protected against dust and connector damage and packed without sharp bends. Labels can include the customer reference and host-platform note when requested for a controlled deployment. Neutral packaging and customer-specific packing documentation are available on request.

Frequently Asked Questions

Is this an original NVIDIA/Mellanox cable?

No. It is an HT-manufactured compatible alternative for equipment that specifies NVIDIA/Mellanox MFA7U10-H015-FLT.

Are separate transceivers or patch leads required?

No. This is one complete direct-attach assembly. The ends are not detachable modules and should not be separated from the cable.

Can excess cable be folded into a compact bundle?

No. Use a supported, bend-safe service loop and observe the listed minimum bend radius. Do not crease the cable or tighten ties around the connector boots.

Will any matching connector operate at the same speed?

Not necessarily. Both hosts must support the stated rate, identification, lane mapping and any required breakout configuration; mechanical compatibility alone is insufficient.


About us

China Factory:No 168 Golden Ground Industrial Area;
Philippines Address:Makati City,Metro Manila, Philippines

Products catalogues

For products catalogue/data sheets or any general inquiry, please email info@huihongfiber.com and we will reply with details.

Customer Support

For customer support, please email sales@huihongfiber.com; our support team will get back to you as soon as possible.