Juniper Networks OSFP-800G-AOC-10M Compatible 800G OSFP 8 x 100G PAM4 IHS/Finned Top Active Optical Cable, 10m (33ft)

Juniper Networks OSFP-800G-AOC-10M Compatible 800G OSFP 8 x 100G PAM4 IHS/Finned Top Active Optical Cable, 10m (33ft)

A successful 800G link depends on host acceptance as well as physical fit. This OSFP-800G-AOC-10M compatible AOC assembly combines OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top) with a fixed 10m (33ft) cable for Juniper Networks equipment. The specifications, configuration guidance and live-link factory verification below describe the exact product supplied under this reference.

OEM Part Number: OSFP-800G-AOC-10MHT Part Number: OSFP-800G-AOC-10M

Product Highlights

  • Compatible alternative to Juniper Networks OSFP-800G-AOC-10M
  • 800G connectivity at 800Gbps
  • Interface configuration: OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)
  • Fixed length and part number: 10m (33ft), OSFP-800G-AOC-10M
  • Cable construction: Active Optical Cable
  • Maximum power consumption: 14W Per End
  • Minimum bend radius: 30mm
  • Operating temperature: 0 to 70°C (32 to 158°F)

Specifications

HT Part NumberOSFP-800G-AOC-10M
Juniper Networks CompatibleOSFP-800G-AOC-10M
ManufacturerHT
Form FactorOSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)
Max. Data Rate800Gbps
Cable Length10m (33ft)
Cable TypeActive Optical Cable
Wavelength850nm
Minimum Bend Radius30mm
Transmitter TypeVCSEL
Receiver TypePIN
Max. Power Consumption14W Per End
Modulation Format8x 100G-PAM4
CDR (Clock and Data Recovery)TX & RX Built-in CDR
Jacket MaterialOFNP
DDM/DOMSupported
Commercial Temperature Range0 to 70°C (32 to 158°F)
ProtocolsOSFP MSA, CMIS Rev 4.0, SFF-8679, IEEE 802.3bs

Juniper Deployment Reference

Juniper platform documentation distinguishes straight QSFP28 DAC or AOC connections from DACBO and AOCBO breakout operation. On channelized systems, the host port must be configured for the required breakout mode. Match this HT compatible cable to the exact Juniper part number and the intended platform configuration.

Network and Protocol Considerations

The intended application is determined by the host interface and protocol support. Listed interface and protocol references include OSFP MSA, CMIS Rev 4.0, SFF-8679, IEEE 802.3bs. Confirm that the host firmware and port configuration support the same operating mode.

Integrated Optical Assembly

The optical engines and fiber are permanently integrated into this AOC. There are no detachable optical modules to clean or exchange. Handle the complete assembly by its connector housings and cable, and keep both ends matched to the same interface specification.

Length Selection and Installation Planning

The extended 10m (33ft) configuration gives OSFP-800G-AOC-10M a specific place in the family reach range. It should not be treated as a universal substitute for every shorter order code. Match it to a documented route, protect the integrated optical cable and both optical engines during handling and retain the part-number label for later maintenance. Within this family, OSFP-800G-AOC-7M is shorter at 7m (23ft), while OSFP-800G-AOC-15M is the next longer choice at 15m (49ft); comparing those two boundaries helps avoid both tension and unnecessary slack.

Position Within the Length Range

OSFP-800G-AOC-10M occupies the middle of this family between OSFP-800G-AOC-7M at 7m (23ft) and OSFP-800G-AOC-15M at 15m (49ft). It adds 3m over the shorter option for extra routing clearance, while the next longer version adds another 5m. Measure the managed path and choose this version when its reach is sufficient without creating the slack associated with the longer assembly.

Interoperability and Configuration Checks

Check three layers before deployment: the host must accept the cable identification, the port must support the stated aggregate rate, and the lane configuration must match the attached interfaces. On breakout hardware, also confirm channelization and the mapping of every branch. These checks are particularly important when similar-looking ports operate at different speeds or under different firmware settings. For this assembly, the minimum bend radius is 30mm; the stated power consumption is 14W Per End; the jacket material is OFNP.

Signal and Lane Configuration

The listed modulation format is 8x 100G-PAM4. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.

Power and Thermal Planning

The rated power consumption is 14W Per End. Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.

Cable Construction and Routing

This assembly uses OFNP jacket, minimum bend radius 30mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.

Ordering Information

Specify the OEM part number and fixed length, then provide the intended host configuration if the link uses channelized or breakout ports. Separate part numbers should be used for separate lengths. This gives the compatibility review enough information to check both the physical assembly and the intended operating mode. Quantity and any labeling instructions should be attached specifically to OSFP-800G-AOC-10M.

Juniper Networks Compatibility and Factory Testing

The verification process combines digital identification with a live link test and diagnostic observation. Host model, hardware revision and software release are useful inputs because qualification behavior can change between platform generations; those details allow platform-specific requirements to be reviewed before the cable is packed. Both connectors are examined before the operating test, which includes receive activity and diagnostic indications.

Shipping and Lead Time

Standard configurations normally ship within one to three working days, while production quantities are confirmed with the order. International express, air cargo and sea freight can be selected according to destination and carton volume; customer courier accounts and nominated forwarders are also accepted.

Quality Assurance and Packaging

Functional inspection covers identification, link establishment and the condition of both connector assemblies. The cable is then protected against dust and connector damage and packed without sharp bends. Labels can include the customer reference and host-platform note when requested for a controlled deployment. Standard protective packing is used by default, with project documentation arranged when requested.

Frequently Asked Questions

Is this an original Juniper Networks cable?

No. It is an HT-manufactured compatible alternative for equipment that specifies Juniper Networks OSFP-800G-AOC-10M.

Will any matching connector operate at the same speed?

Not necessarily. Both hosts must support the stated rate, identification, lane mapping and any required breakout configuration; mechanical compatibility alone is insufficient.

What details assist a compatibility review?

Provide the equipment manufacturer, model, port type, hardware revision and software release, together with the OEM reference, required length and quantity.

How should an unused assembly be stored?

Protect both connector ends, keep the cable in a loose bend-safe coil and retain its part-number label so the length and compatibility identity remain traceable.


About us

China Factory:No 168 Golden Ground Industrial Area;
Philippines Address:Makati City,Metro Manila, Philippines

Products catalogues

For products catalogue/data sheets or any general inquiry, please email info@huihongfiber.com and we will reply with details.

Customer Support

For customer support, please email sales@huihongfiber.com; our support team will get back to you as soon as possible.