
A successful 800G link depends on host acceptance as well as physical fit. This OSFP (IHS/Finned Top) to 4x OSFP (IHS/Finned Top)-800G-DAC-2M7FT compatible DAC assembly combines OSFP (IHS/Finned Top) to 4x OSFP (IHS/Finned Top) with a fixed 2m (7ft) cable for Generic equipment. The specifications, configuration guidance and live-link factory verification below describe the exact product supplied under this reference.
OEM Part Number: OSFP (IHS/Finned Top) to 4x OSFP (IHS/Finned Top)-800G-DAC-2M7FTHT Part Number: OSFP (IHS/Finned Top) to 4x OSFP (IHS/Finned Top)-800G-DAC-2M7FT
| HT Part Number | OSFP (IHS/Finned Top) to 4x OSFP (IHS/Finned Top)-800G-DAC-2M7FT |
|---|---|
| Manufacturer | HT |
| Form Factor | OSFP (IHS/Finned Top) to 4x OSFP (IHS/Finned Top) |
| Max. Data Rate | 800Gbps |
| Media | Copper |
| Cable Type | Passive Breakout DAC |
| Cable Length | 2m (7ft) |
| Wire AWG | 28AWG |
| Minimum Bend Radius | 31mm |
| Max. Power Consumption | 0.1W (800G End), 0.1W (200G Per End) |
| Jacket Material | PVC (OFNR) |
| Commercial Temperature Range | 0 to 70°C (32 to 158°F) |
| Modulation Format | 8x100G-PAM4 to Quad 2x100G-PAM4 |
| Application | 800G/200G Ethernet |
| Protocols | OSFP MSA, CMIS Rev4.0, IEEE 802.3ck |
The listed modulation format is 8x100G-PAM4 to Quad 2x100G-PAM4. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.
This assembly uses 28AWG conductors, PVC (OFNR) jacket, minimum bend radius 31mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.
The intended application is 800G/200G Ethernet. Listed interface and protocol references include OSFP MSA, CMIS Rev4.0, IEEE 802.3ck. Confirm that the host firmware and port configuration support the same operating mode.
The OSFP (IHS/Finned Top) to 4x OSFP (IHS/Finned Top) configuration divides the high-speed interface into multiple lower-speed connections. Verify the upstream lane assignment, downstream port speeds and breakout setting on the host before connecting the assembly. Each branch must attach to the correct remote interface.
A passive DAC has no separate optical conversion stage. Its low-power, low-latency operation is useful for short equipment links, but the assembly must remain within the length and signaling mode accepted by both hosts.
OSFP (IHS/Finned Top) to 4x OSFP (IHS/Finned Top)-800G-DAC-2M7FT provides 2m (7ft) for connections between separated rack units or nearby equipment positions. Plan the route around cable managers and power cords, keeping the assembly free from connector strain while avoiding a large obstruction in the airflow path.
OSFP (IHS/Finned Top) to 4x OSFP (IHS/Finned Top)-800G-DAC-2M7FT is the longest of 4 verified length options in this family. Compared with OSFP (IHS/Finned Top) to 4x OSFP (IHS/Finned Top)-800G-DAC-1.5M5FT at 1.5m (5ft), it provides 0.5m of additional reach for a longer vertical drop, a wider rack or an adjacent-cabinet route. Confirm that the complete path requires this length, because unused slack still needs supported, bend-safe storage.
Check three layers before deployment: the host must accept the cable identification, the port must support the stated aggregate rate, and the lane configuration must match the attached interfaces. On breakout hardware, also confirm channelization and the mapping of every branch. These checks are particularly important when similar-looking ports operate at different speeds or under different firmware settings. For this assembly, the listed conductor specification is 28AWG; the minimum bend radius is 31mm; the stated power consumption is 0.1W (800G End), 0.1W (200G Per End); the jacket material is PVC (OFNR).
The rated power consumption is 0.1W (800G End), 0.1W (200G Per End). Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.
Specify the OEM part number and fixed length, then provide the intended host configuration if the link uses channelized or breakout ports. Separate part numbers should be used for separate lengths. This gives the compatibility review enough information to check both the physical assembly and the intended operating mode. Keep OSFP (IHS/Finned Top) to 4x OSFP (IHS/Finned Top)-800G-DAC-2M7FT associated with 2m (7ft) throughout the order and receiving record.
The verification process combines digital identification with a live link test and diagnostic observation. Host model, hardware revision and software release are useful inputs because qualification behavior can change between platform generations; those details allow platform-specific requirements to be reviewed before the cable is packed. Both connectors are examined before the operating test, which includes link stability and diagnostic indications.
Standard configurations normally ship within one to three working days, while production quantities are confirmed with the order. International express, air cargo and sea freight can be selected according to destination and carton volume; customer courier accounts and nominated forwarders are also accepted.
Functional inspection covers identification, link establishment and the condition of both connector assemblies. The cable is then protected against dust and connector damage and packed without sharp bends. Labels can include the customer reference and host-platform note when requested for a controlled deployment. Volume orders can include customer references on the labels and carton list.
No. It is manufactured by HT under our own manufacturer identity.
No. This is one complete direct-attach assembly. The ends are not detachable modules and should not be separated from the cable.
No. Use a supported, bend-safe service loop and observe the listed minimum bend radius. Do not crease the cable or tighten ties around the connector boots.
Not necessarily. Both hosts must support the stated rate, identification, lane mapping and any required breakout configuration; mechanical compatibility alone is insufficient.