Use this 2.5m (8ft) DAC cable for hosts expecting Generic OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-400G-DAC-2.5M8FT and a 400G direct-attached interface. The assembly uses OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top); lane, protocol and breakout considerations are documented alongside the verified table. Every alternative length remains a separate order code with its own technical page.
OEM Part Number: OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-400G-DAC-2.5M8FTHT Part Number: OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-400G-DAC-2.5M8FT
| HT Part Number | OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-400G-DAC-2.5M8FT |
|---|---|
| Manufacturer | HT |
| Form Factor | OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top) |
| Max. Data Rate | 400Gbps |
| Media | Copper |
| Cable Type | Passive DAC |
| Minimum Bend Radius | 40.5mm |
| Max. Power Consumption | 0.1W Per End |
| Cable Length | 2.5m (8ft) |
| Wire AWG | 28AWG |
| Temperature Range | 0 to 70°C (32 to 158°F) |
| Jacket Material | PVC |
| Protocols | OSFP MSA, IEEE 802.3cd 100GBase-CR2, CMIS 4.0 |
| Modulation Format | 8x 50G-PAM4 |
The listed modulation format is 8x 50G-PAM4. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.
Check three layers before deployment: the host must accept the cable identification, the port must support the stated aggregate rate, and the lane configuration must match the attached interfaces. On breakout hardware, also confirm channelization and the mapping of every branch. These checks are particularly important when similar-looking ports operate at different speeds or under different firmware settings. For this assembly, the listed conductor specification is 28AWG; the minimum bend radius is 40.5mm; the stated power consumption is 0.1W Per End; the jacket material is PVC.
The rated power consumption is 0.1W Per End. Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.
This assembly uses 28AWG conductors, PVC jacket, minimum bend radius 40.5mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.
The intended application is determined by the host interface and protocol support. Listed interface and protocol references include OSFP MSA, IEEE 802.3cd 100GBase-CR2, CMIS 4.0. Confirm that the host firmware and port configuration support the same operating mode.
A passive DAC has no separate optical conversion stage. Its low-power, low-latency operation is useful for short equipment links, but the assembly must remain within the length and signaling mode accepted by both hosts.
The 2.5m (8ft) version is useful when a two-metre run would leave insufficient working slack. Before installation, check the complete horizontal and vertical path so that OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-400G-DAC-2.5M8FT reaches both ports without tension at either connector.
OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-400G-DAC-2.5M8FT occupies the middle of this family between OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-400G-DAC-2M7FT at 2m (7ft) and OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-400G-DAC-3M10FT at 3m (10ft). It adds 0.5m over the shorter option for extra routing clearance, while the next longer version adds another 0.5m. Measure the managed path and choose this version when its reach is sufficient without creating the slack associated with the longer assembly.
Specify the OEM part number and fixed length, then provide the intended host configuration if the link uses channelized or breakout ports. Separate part numbers should be used for separate lengths. This gives the compatibility review enough information to check both the physical assembly and the intended operating mode. Quantity and any labeling instructions should be attached specifically to OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-400G-DAC-2.5M8FT.
The verification process combines digital identification with a live link test and diagnostic observation. Host model, hardware revision and software release are useful inputs because qualification behavior can change between platform generations; those details allow platform-specific requirements to be reviewed before the cable is packed. Both connectors are examined before the operating test, which includes link stability and diagnostic indications.
Standard configurations normally ship within one to three working days, while production quantities are confirmed with the order. International express, air cargo and sea freight can be selected according to destination and carton volume; customer courier accounts and nominated forwarders are also accepted.
Functional inspection covers identification, link establishment and the condition of both connector assemblies. The cable is then protected against dust and connector damage and packed without sharp bends. Labels can include the customer reference and host-platform note when requested for a controlled deployment. Volume orders can include customer references on the labels and carton list.
No. It is manufactured by HT under our own manufacturer identity.
Only where both hosts explicitly support the complete interface and compatibility arrangement. Document each end and select the appropriate brand-specific product when required.
No. OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-400G-DAC-2.5M8FT refers here to 2.5m (8ft). Every other verified length has a separate part number and page in the length list.
No. This is one complete direct-attach assembly. The ends are not detachable modules and should not be separated from the cable.