Philippines Fiber Optics

Connect the people, connect the world ...

Fiber Optic Cables

OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-800G-ACC-5M16FT 800G Twin-port OSFP 8 x 100G PAM4 IHS/Finned Top Active Copper Twinax Cable, 5m (16ft)

OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-800G-ACC-5M16FT 800G Twin-port OSFP 8 x 100G PAM4 IHS/Finned Top Active Copper Twinax Cable, 5m (16ft)

A successful 800G link depends on host acceptance as well as physical fit. This OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-800G-ACC-5M16FT compatible ACC assembly combines OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top) with a fixed 5m (16ft) cable for Generic equipment. The specifications, configuration guidance and live-link factory verification below describe the exact product supplied under this reference.

OEM Part Number: OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-800G-ACC-5M16FTHT Part Number: OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-800G-ACC-5M16FT

Product Highlights

  • HT-manufactured ACC assembly in 5m (16ft)
  • 800G connectivity at 850Gbps (8x 106.25Gbps)
  • Interface configuration: OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)
  • Fixed length and part number: 5m (16ft), OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-800G-ACC-5M16FT
  • Cable construction: Active DAC (ACC)
  • Conductor specification: 26AWG
  • Maximum power consumption: 1.3W Per End
  • Minimum bend radius: 59.5mm

Specifications

HT Part NumberOSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-800G-ACC-5M16FT
ManufacturerHT
Form FactorOSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)
Max. Data Rate850Gbps (8x 106.25Gbps)
MediaCopper
Cable TypeActive DAC (ACC)
Cable Length5m (16ft)
Wire AWG26AWG
Minimum Bend Radius59.5mm
Max. Power Consumption1.3W Per End
Jacket MaterialPET
Commercial Temperature Range0 to 70°C (32 to 158°F)
Modulation Format8x100G-PAM4
Application800G Ethernet
ProtocolsCMIS 5.0, IEEE 802.3ck, OSFP Rev5.0

Signal and Lane Configuration

The listed modulation format is 8x100G-PAM4. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.

Network and Protocol Considerations

The intended application is 800G Ethernet. Listed interface and protocol references include CMIS 5.0, IEEE 802.3ck, OSFP Rev5.0. Confirm that the host firmware and port configuration support the same operating mode.

Length Selection and Installation Planning

The 5m (16ft) length gives OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-800G-ACC-5M16FT more freedom for adjacent-rack and row-end deployments. Longer copper runs need particular attention to routing weight and bend control; the ACC specification and host support must still match the intended link.

Position Within the Length Range

OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-800G-ACC-5M16FT is the longest of 5 verified length options in this family. Compared with OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-800G-ACC-4M13FT at 4m (13ft), it provides 1m of additional reach for a longer vertical drop, a wider rack or an adjacent-cabinet route. Confirm that the complete path requires this length, because unused slack still needs supported, bend-safe storage.

Interoperability and Configuration Checks

Check three layers before deployment: the host must accept the cable identification, the port must support the stated aggregate rate, and the lane configuration must match the attached interfaces. On breakout hardware, also confirm channelization and the mapping of every branch. These checks are particularly important when similar-looking ports operate at different speeds or under different firmware settings. For this assembly, the listed conductor specification is 26AWG; the minimum bend radius is 59.5mm; the stated power consumption is 1.3W Per End; the jacket material is PET.

Power and Thermal Planning

The rated power consumption is 1.3W Per End. Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.

Cable Construction and Routing

This assembly uses 26AWG conductors, PET jacket, minimum bend radius 59.5mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.

Ordering Information

Specify the OEM part number and fixed length, then provide the intended host configuration if the link uses channelized or breakout ports. Separate part numbers should be used for separate lengths. This gives the compatibility review enough information to check both the physical assembly and the intended operating mode. Quantity and any labeling instructions should be attached specifically to OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-800G-ACC-5M16FT.

Generic Compatibility and Factory Testing

The verification process combines digital identification with a live link test and diagnostic observation. Host model, hardware revision and software release are useful inputs because qualification behavior can change between platform generations; those details allow platform-specific requirements to be reviewed before the cable is packed. The check includes link stability and diagnostic indications, followed by a final inspection of both ends.

Shipping and Lead Time

Standard configurations normally ship within one to three working days, while production quantities are confirmed with the order. International express, air cargo and sea freight can be selected according to destination and carton volume; customer courier accounts and nominated forwarders are also accepted.

Quality Assurance and Packaging

Functional inspection covers identification, link establishment and the condition of both connector assemblies. The cable is then protected against dust and connector damage and packed without sharp bends. Labels can include the customer reference and host-platform note when requested for a controlled deployment. Neutral packaging and customer-specific packing documentation are available on request.

Frequently Asked Questions

Is this an original equipment manufacturer cable?

No. It is manufactured by HT under our own manufacturer identity.

How should an unused assembly be stored?

Protect both connector ends, keep the cable in a loose bend-safe coil and retain its part-number label so the length and compatibility identity remain traceable.

Can different brands be connected with the same assembly?

Only where both hosts explicitly support the complete interface and compatibility arrangement. Document each end and select the appropriate brand-specific product when required.

Does this order code cover multiple lengths?

No. OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-800G-ACC-5M16FT refers here to 5m (16ft). Every other verified length has a separate part number and page in the length list.


About us

China Factory:No 168 Golden Ground Industrial Area;
Philippines Address:Makati City,Metro Manila, Philippines

Products catalogues

For products catalogue/data sheets or any general inquiry, please email info@huihongfiber.com and we will reply with details.

Customer Support

For customer support, please email sales@huihongfiber.com; our support team will get back to you as soon as possible.