Philippines Fiber Optics

Connect the people, connect the world ...

Fiber Optic Cables

OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-800G-DAC-1.5M5FT 800G OSFP 8 x 100G PAM4 IHS/Finned Top Passive Copper Twinax Cable, 1.5m (5ft)

OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-800G-DAC-1.5M5FT 800G OSFP 8 x 100G PAM4 IHS/Finned Top Passive Copper Twinax Cable, 1.5m (5ft)

The OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-800G-DAC-1.5M5FT compatible assembly addresses a specific interoperability requirement: Generic host identification on a 800G DAC link measuring 1.5m (5ft). Its interface configuration is OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top). This page explains the physical product, port-configuration checks and related part numbers so selection does not rely on connector appearance alone.

OEM Part Number: OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-800G-DAC-1.5M5FTHT Part Number: OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-800G-DAC-1.5M5FT

Product Highlights

  • HT-manufactured DAC assembly in 1.5m (5ft)
  • 800G connectivity at 800Gbps
  • Interface configuration: OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)
  • Fixed length and part number: 1.5m (5ft), OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-800G-DAC-1.5M5FT
  • Cable construction: Passive DAC
  • Conductor specification: 26AWG
  • Maximum power consumption: 0.1W Per End
  • Minimum bend radius: 69mm

Specifications

HT Part NumberOSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-800G-DAC-1.5M5FT
ManufacturerHT
Form FactorOSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)
Max. Data Rate800Gbps
MediaCopper
Cable TypePassive DAC
Cable Length1.5m (5ft)
Jacket MaterialPET
Minimum Bend Radius69mm
Wire AWG26AWG
Max. Power Consumption0.1W Per End
Modulation Format8x100G-PAM4
Commercial Temperature Range0 to 70°C (32 to 158°F)
Application800G Ethernet
ProtocolsOSFP MSA, IEEE 802.3ck, CMIS v4.0

Signal and Lane Configuration

The listed modulation format is 8x100G-PAM4. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.

Position Within the Length Range

OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-800G-DAC-1.5M5FT occupies the middle of this family between OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-800G-DAC-1M3FT at 1m (3ft) and OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-800G-DAC-2M7FT at 2m (7ft). It adds 0.5m over the shorter option for extra routing clearance, while the next longer version adds another 0.5m. Measure the managed path and choose this version when its reach is sufficient without creating the slack associated with the longer assembly.

Interoperability and Configuration Checks

Check three layers before deployment: the host must accept the cable identification, the port must support the stated aggregate rate, and the lane configuration must match the attached interfaces. On breakout hardware, also confirm channelization and the mapping of every branch. These checks are particularly important when similar-looking ports operate at different speeds or under different firmware settings. For this assembly, the listed conductor specification is 26AWG; the minimum bend radius is 69mm; the stated power consumption is 0.1W Per End; the jacket material is PET.

Power and Thermal Planning

The rated power consumption is 0.1W Per End. Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.

Cable Construction and Routing

This assembly uses 26AWG conductors, PET jacket, minimum bend radius 69mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.

Network and Protocol Considerations

The intended application is 800G Ethernet. Listed interface and protocol references include OSFP MSA, IEEE 802.3ck, CMIS v4.0. Confirm that the host firmware and port configuration support the same operating mode.

Passive Copper Operation

A passive DAC has no separate optical conversion stage. Its low-power, low-latency operation is useful for short equipment links, but the assembly must remain within the length and signaling mode accepted by both hosts.

Length Selection and Installation Planning

The additional half metre beyond a one-metre assembly gives OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-800G-DAC-1.5M5FT useful routing flexibility when the ports are not directly aligned. It can accommodate a different rack unit or a short service loop, but excess cable should be dressed loosely rather than folded into a tight coil.

Ordering Information

Specify the OEM part number and fixed length, then provide the intended host configuration if the link uses channelized or breakout ports. Separate part numbers should be used for separate lengths. This gives the compatibility review enough information to check both the physical assembly and the intended operating mode. This page’s fixed configuration is 1.5m (5ft); another length must be quoted under its corresponding part number.

Generic Compatibility and Factory Testing

The verification process combines digital identification with a live link test and diagnostic observation. Host model, hardware revision and software release are useful inputs because qualification behavior can change between platform generations; those details allow platform-specific requirements to be reviewed before the cable is packed. Both connectors are examined before the operating test, which includes link stability and diagnostic indications.

Shipping and Lead Time

Standard configurations normally ship within one to three working days, while production quantities are confirmed with the order. International express, air cargo and sea freight can be selected according to destination and carton volume; customer courier accounts and nominated forwarders are also accepted.

Quality Assurance and Packaging

Functional inspection covers identification, link establishment and the condition of both connector assemblies. The cable is then protected against dust and connector damage and packed without sharp bends. Labels can include the customer reference and host-platform note when requested for a controlled deployment. Standard protective packing is used by default, with project documentation arranged when requested.

Frequently Asked Questions

Is this an original equipment manufacturer cable?

No. It is manufactured by HT under our own manufacturer identity.

Can excess cable be folded into a compact bundle?

No. Use a supported, bend-safe service loop and observe the listed minimum bend radius. Do not crease the cable or tighten ties around the connector boots.

Will any matching connector operate at the same speed?

Not necessarily. Both hosts must support the stated rate, identification, lane mapping and any required breakout configuration; mechanical compatibility alone is insufficient.

What details assist a compatibility review?

Provide the equipment manufacturer, model, port type, hardware revision and software release, together with the OEM reference, required length and quantity.


About us

China Factory:No 168 Golden Ground Industrial Area;
Philippines Address:Makati City,Metro Manila, Philippines

Products catalogues

For products catalogue/data sheets or any general inquiry, please email info@huihongfiber.com and we will reply with details.

Customer Support