Philippines Fiber Optics

Connect the people, connect the world ...

Fiber Optic Cables

OSFP (RHS/Flat Top) to OSFP (RHS/Flat Top)-1.6T-ACC-1M3FT 1.6T OSFP224 8 x 200G PAM4 RHS/Flat Top Active Copper Twinax Cable, 1m (3ft)

OSFP (RHS/Flat Top) to OSFP (RHS/Flat Top)-1.6T-ACC-1M3FT 1.6T OSFP224 8 x 200G PAM4 RHS/Flat Top Active Copper Twinax Cable, 1m (3ft)

Use this 1m (3ft) ACC cable for hosts expecting Generic OSFP (RHS/Flat Top) to OSFP (RHS/Flat Top)-1.6T-ACC-1M3FT and a 1.6T direct-attached interface. The assembly uses OSFP (RHS/Flat Top) to OSFP (RHS/Flat Top); lane, protocol and breakout considerations are documented alongside the verified table. Every alternative length remains a separate order code with its own technical page.

OEM Part Number: OSFP (RHS/Flat Top) to OSFP (RHS/Flat Top)-1.6T-ACC-1M3FTHT Part Number: OSFP (RHS/Flat Top) to OSFP (RHS/Flat Top)-1.6T-ACC-1M3FT

Product Highlights

  • HT-manufactured ACC assembly in 1m (3ft)
  • 1.6T connectivity at 1600Gbps
  • Interface configuration: OSFP (RHS/Flat Top) to OSFP (RHS/Flat Top)
  • Fixed length and part number: 1m (3ft), OSFP (RHS/Flat Top) to OSFP (RHS/Flat Top)-1.6T-ACC-1M3FT
  • Cable construction: Active DAC (ACC)
  • Conductor specification: 25AWG
  • Maximum power consumption: 2.5W Per End
  • Minimum bend radius: 60mm

Specifications

HT Part NumberOSFP (RHS/Flat Top) to OSFP (RHS/Flat Top)-1.6T-ACC-1M3FT
ManufacturerHT
Form FactorOSFP (RHS/Flat Top) to OSFP (RHS/Flat Top)
Max. Data Rate1600Gbps
MediaCopper
Cable TypeActive DAC (ACC)
Cable Length1m (3ft)
Jacket MaterialLSZH
Minimum Bend Radius60mm
Wire AWG25AWG
Max. Power Consumption2.5W Per End
Modulation Format8x 200G-PAM4 to 8x 200G-PAM4
Commercial Temperature Range0 to 70°C (32 to 158°F)
Application1.6T Ethernet
ProtocolsOSFP Rev 5.2, CMIS 5.0, IEEE 802.3df and 802.3dj

Signal and Lane Configuration

The listed modulation format is 8x 200G-PAM4 to 8x 200G-PAM4. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.

Interoperability and Configuration Checks

Check three layers before deployment: the host must accept the cable identification, the port must support the stated aggregate rate, and the lane configuration must match the attached interfaces. On breakout hardware, also confirm channelization and the mapping of every branch. These checks are particularly important when similar-looking ports operate at different speeds or under different firmware settings. For this assembly, the listed conductor specification is 25AWG; the minimum bend radius is 60mm; the stated power consumption is 2.5W Per End; the jacket material is LSZH.

Power and Thermal Planning

The rated power consumption is 2.5W Per End. Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.

Cable Construction and Routing

This assembly uses 25AWG conductors, LSZH jacket, minimum bend radius 60mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.

Network and Protocol Considerations

The intended application is 1.6T Ethernet. Listed interface and protocol references include OSFP Rev 5.2, CMIS 5.0, IEEE 802.3df and 802.3dj. Confirm that the host firmware and port configuration support the same operating mode.

Length Selection and Installation Planning

At 1m (3ft), OSFP (RHS/Flat Top) to OSFP (RHS/Flat Top)-1.6T-ACC-1M3FT is a practical choice for direct connections within one rack. Route the cable along the intended management path rather than pulling it diagonally across adjacent connectors, and leave enough clearance for insertion, removal and front-panel airflow.

Position Within the Length Range

OSFP (RHS/Flat Top) to OSFP (RHS/Flat Top)-1.6T-ACC-1M3FT is the shortest of 2 verified length options in this family. It is the preferred choice when the port positions are close and cable slack must be kept to a minimum. The next option is OSFP (RHS/Flat Top) to OSFP (RHS/Flat Top)-1.6T-ACC-2M7FT at 2m (7ft), adding 1m for a less direct routing path; selecting it unnecessarily would leave more cable to dress.

Ordering Information

Specify the OEM part number and fixed length, then provide the intended host configuration if the link uses channelized or breakout ports. Separate part numbers should be used for separate lengths. This gives the compatibility review enough information to check both the physical assembly and the intended operating mode. This page’s fixed configuration is 1m (3ft); another length must be quoted under its corresponding part number.

Generic Compatibility and Factory Testing

The verification process combines digital identification with a live link test and diagnostic observation. Host model, hardware revision and software release are useful inputs because qualification behavior can change between platform generations; those details allow platform-specific requirements to be reviewed before the cable is packed. The check includes link stability and diagnostic indications, followed by a final inspection of both ends.

Shipping and Lead Time

Available stock is generally dispatched within one to three working days after order confirmation, with production lead times advised for larger quantities. Worldwide courier services are available, with air or sea freight for consolidated shipments; freight-collect delivery and coordination with a customer’s logistics provider can be arranged.

Quality Assurance and Packaging

Functional inspection covers identification, link establishment and the condition of both connector assemblies. The cable is then protected against dust and connector damage and packed without sharp bends. Labels can include the customer reference and host-platform note when requested for a controlled deployment. Standard protective packing is used by default, with project documentation arranged when requested.

Frequently Asked Questions

Is this an original equipment manufacturer cable?

No. It is manufactured by HT under our own manufacturer identity.

Can different brands be connected with the same assembly?

Only where both hosts explicitly support the complete interface and compatibility arrangement. Document each end and select the appropriate brand-specific product when required.

Does this order code cover multiple lengths?

No. OSFP (RHS/Flat Top) to OSFP (RHS/Flat Top)-1.6T-ACC-1M3FT refers here to 1m (3ft). Every other verified length has a separate part number and page in the length list.

Are separate transceivers or patch leads required?

No. This is one complete direct-attach assembly. The ends are not detachable modules and should not be separated from the cable.


About us

China Factory:No 168 Golden Ground Industrial Area;
Philippines Address:Makati City,Metro Manila, Philippines

Products catalogues

For products catalogue/data sheets or any general inquiry, please email info@huihongfiber.com and we will reply with details.

Customer Support

For customer support, please email sales@huihongfiber.com; our support team will get back to you as soon as possible.