The OSFP (RHS/Flat Top) to OSFP (RHS/Flat Top)-400G-DAC-2M7FT compatible assembly addresses a specific interoperability requirement: Generic host identification on a 400G DAC link measuring 2m (7ft). Its interface configuration is OSFP (RHS/Flat Top) to OSFP (RHS/Flat Top). This page explains the physical product, port-configuration checks and related part numbers so selection does not rely on connector appearance alone.
OEM Part Number: OSFP (RHS/Flat Top) to OSFP (RHS/Flat Top)-400G-DAC-2M7FTHT Part Number: OSFP (RHS/Flat Top) to OSFP (RHS/Flat Top)-400G-DAC-2M7FT
| HT Part Number | OSFP (RHS/Flat Top) to OSFP (RHS/Flat Top)-400G-DAC-2M7FT |
|---|---|
| Manufacturer | HT |
| Form Factor | OSFP (RHS/Flat Top) to OSFP (RHS/Flat Top) |
| Max Data Rate | 400Gbps |
| Media | Copper |
| Cable Type | Passive Twinax |
| Cable Length | 2m (7ft) |
| Wire AWG | 28AWG |
| Minimum Bend Radius | 40.5mm |
| Max. Power Consumption | 0.1W |
| Jacket Material | PVC (OFNR) |
| Commercial Temperature Range | 0 to 70°C (32 to 158°F) |
| Protocols | OSFP MSA, CMIS Rev4.0, IEEE 802.3cd |
| Modulation Format | 4x 100G-PAM4 |
The listed modulation format is 4x 100G-PAM4. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.
OSFP (RHS/Flat Top) to OSFP (RHS/Flat Top)-400G-DAC-2M7FT is the longest of 4 verified length options in this family. Compared with OSFP (RHS/Flat Top) to OSFP (RHS/Flat Top)-400G-DAC-1.5M5FT at 1.5m (5ft), it provides 0.5m of additional reach for a longer vertical drop, a wider rack or an adjacent-cabinet route. Confirm that the complete path requires this length, because unused slack still needs supported, bend-safe storage.
Check three layers before deployment: the host must accept the cable identification, the port must support the stated aggregate rate, and the lane configuration must match the attached interfaces. On breakout hardware, also confirm channelization and the mapping of every branch. These checks are particularly important when similar-looking ports operate at different speeds or under different firmware settings. For this assembly, the listed conductor specification is 28AWG; the minimum bend radius is 40.5mm; the stated power consumption is 0.1W; the jacket material is PVC (OFNR).
The rated power consumption is 0.1W. Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.
This assembly uses 28AWG conductors, PVC (OFNR) jacket, minimum bend radius 40.5mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.
The intended application is determined by the host interface and protocol support. Listed interface and protocol references include OSFP MSA, CMIS Rev4.0, IEEE 802.3cd. Confirm that the host firmware and port configuration support the same operating mode.
A passive DAC has no separate optical conversion stage. Its low-power, low-latency operation is useful for short equipment links, but the assembly must remain within the length and signaling mode accepted by both hosts.
OSFP (RHS/Flat Top) to OSFP (RHS/Flat Top)-400G-DAC-2M7FT provides 2m (7ft) for connections between separated rack units or nearby equipment positions. Plan the route around cable managers and power cords, keeping the assembly free from connector strain while avoiding a large obstruction in the airflow path.
Specify the OEM part number and fixed length, then provide the intended host configuration if the link uses channelized or breakout ports. Separate part numbers should be used for separate lengths. This gives the compatibility review enough information to check both the physical assembly and the intended operating mode. Quantity and any labeling instructions should be attached specifically to OSFP (RHS/Flat Top) to OSFP (RHS/Flat Top)-400G-DAC-2M7FT.
The verification process combines digital identification with a live link test and diagnostic observation. Host model, hardware revision and software release are useful inputs because qualification behavior can change between platform generations; those details allow platform-specific requirements to be reviewed before the cable is packed. Where supported by the host, link stability and diagnostic indications are reviewed together with the established link.
Standard configurations normally ship within one to three working days, while production quantities are confirmed with the order. International express, air cargo and sea freight can be selected according to destination and carton volume; customer courier accounts and nominated forwarders are also accepted.
Functional inspection covers identification, link establishment and the condition of both connector assemblies. The cable is then protected against dust and connector damage and packed without sharp bends. Labels can include the customer reference and host-platform note when requested for a controlled deployment. Neutral packaging and customer-specific packing documentation are available on request.
No. It is manufactured by HT under our own manufacturer identity.
No. Use a supported, bend-safe service loop and observe the listed minimum bend radius. Do not crease the cable or tighten ties around the connector boots.
Not necessarily. Both hosts must support the stated rate, identification, lane mapping and any required breakout configuration; mechanical compatibility alone is insufficient.
Provide the equipment manufacturer, model, port type, hardware revision and software release, together with the OEM reference, required length and quantity.