Philippines Fiber Optics

Connect the people, connect the world ...

Fiber Optic Cables

Cisco Q56-200-CU2M Compatible 200G QSFP56 4 x 50G PAM4 Passive Copper Twinax Cable, 2m (7ft)

Cisco Q56-200-CU2M Compatible 200G QSFP56 4 x 50G PAM4 Passive Copper Twinax Cable, 2m (7ft)

A successful 200G link depends on host acceptance as well as physical fit. This Q56-200-CU2M compatible DAC assembly combines QSFP56 to QSFP56 with a fixed 2m (7ft) cable for Cisco equipment. The specifications, configuration guidance and live-link factory verification below describe the exact product supplied under this reference.

OEM Part Number: Q56-200-CU2MHT Part Number: Q56-200-CU2M

Product Highlights

  • Compatible alternative to Cisco Q56-200-CU2M
  • 200G connectivity at 200Gbps
  • Interface configuration: QSFP56 to QSFP56
  • Fixed length and part number: 2m (7ft), Q56-200-CU2M
  • Cable construction: Passive Twinax
  • Conductor specification: 30AWG
  • Maximum power consumption: 0.03W Per End
  • Minimum bend radius: 39mm

Specifications

HT Part NumberQ56-200-CU2M
Cisco CompatibleQ56-200-CU2M
ManufacturerHT
Form FactorQSFP56 to QSFP56
Max. Data Rate200Gbps
MediaCopper
Cable TypePassive Twinax
Cable Length2m (7ft)
Wire AWG30AWG
Minimum Bend Radius39mm
Max. Power Consumption0.03W Per End
Jacket MaterialPVC
Commercial Temperature Range0 to 70°C (32 to 158°F)
ProtocolsIEEE802.3cd, SFF-8436

Power and Thermal Planning

The rated power consumption is 0.03W Per End. Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.

Network and Protocol Considerations

The intended application is determined by the host interface and protocol support. Listed interface and protocol references include IEEE802.3cd, SFF-8436. Confirm that the host firmware and port configuration support the same operating mode.

Passive Copper Operation

A passive DAC has no separate optical conversion stage. Its low-power, low-latency operation is useful for short equipment links, but the assembly must remain within the length and signaling mode accepted by both hosts.

Length Selection and Installation Planning

Q56-200-CU2M provides 2m (7ft) for connections between separated rack units or nearby equipment positions. Plan the route around cable managers and power cords, keeping the assembly free from connector strain while avoiding a large obstruction in the airflow path.

Position Within the Length Range

Q56-200-CU2M occupies the middle of this family between Q56-200-CU150CM at 1.5m (5ft) and Q56-200-CU3M at 3m (10ft). It adds 0.5m over the shorter option for extra routing clearance, while the next longer version adds another 1m. Measure the managed path and choose this version when its reach is sufficient without creating the slack associated with the longer assembly.

Interoperability and Configuration Checks

Check three layers before deployment: the host must accept the cable identification, the port must support the stated aggregate rate, and the lane configuration must match the attached interfaces. On breakout hardware, also confirm channelization and the mapping of every branch. These checks are particularly important when similar-looking ports operate at different speeds or under different firmware settings. For this assembly, the listed conductor specification is 30AWG; the minimum bend radius is 39mm; the stated power consumption is 0.03W Per End; the jacket material is PVC.

Cable Construction and Routing

This assembly uses 30AWG conductors, PVC jacket, minimum bend radius 39mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.

Ordering Information

Specify the OEM part number and fixed length, then provide the intended host configuration if the link uses channelized or breakout ports. Separate part numbers should be used for separate lengths. This gives the compatibility review enough information to check both the physical assembly and the intended operating mode. Quantity and any labeling instructions should be attached specifically to Q56-200-CU2M.

Cisco Compatibility and Factory Testing

The verification process combines digital identification with a live link test and diagnostic observation. Host model, hardware revision and software release are useful inputs because qualification behavior can change between platform generations; those details allow platform-specific requirements to be reviewed before the cable is packed. Both connectors are examined before the operating test, which includes link stability and diagnostic indications.

Shipping and Lead Time

Available stock is generally dispatched within one to three working days after order confirmation, with production lead times advised for larger quantities. Worldwide courier services are available, with air or sea freight for consolidated shipments; freight-collect delivery and coordination with a customer’s logistics provider can be arranged.

Quality Assurance and Packaging

Functional inspection covers identification, link establishment and the condition of both connector assemblies. The cable is then protected against dust and connector damage and packed without sharp bends. Labels can include the customer reference and host-platform note when requested for a controlled deployment. Volume orders can include customer references on the labels and carton list.

Frequently Asked Questions

Is this an original Cisco cable?

No. It is an HT-manufactured compatible alternative for equipment that specifies Cisco Q56-200-CU2M.

Does this order code cover multiple lengths?

No. Q56-200-CU2M refers here to 2m (7ft). Every other verified length has a separate part number and page in the length list.

Are separate transceivers or patch leads required?

No. This is one complete direct-attach assembly. The ends are not detachable modules and should not be separated from the cable.

Can excess cable be folded into a compact bundle?

No. Use a supported, bend-safe service loop and observe the listed minimum bend radius. Do not crease the cable or tighten ties around the connector boots.


About us