Use this 100m (328ft) AOC cable for hosts expecting Cisco QDD-400-AOC100M and a 400G direct-attached interface. The assembly uses QSFP-DD to QSFP-DD; lane, protocol and breakout considerations are documented alongside the verified table. Every alternative length remains a separate order code with its own technical page.
OEM Part Number: QDD-400-AOC100MHT Part Number: QDD-400-AOC100M
| HT Part Number | QDD-400-AOC100M |
|---|---|
| Cisco Compatible | QDD-400-AOC100M |
| Manufacturer | HT |
| Form Factor | QSFP-DD to QSFP-DD |
| Max. Data Rate | 400Gbps |
| Cable Length | 100m (328ft) |
| Cable Type | OM4 |
| Wavelength | 850nm |
| Minimum Bend Radius | 30mm |
| Transmitter Type | VSCEL |
| Receiver Type | 850nm PIN |
| Max. Power Consumption | 8W Per End |
| Jacket Material | OFNP |
| CDR (Clock and Data Recovery) | TX & RX Built-in CDR |
| Modulation Format | PAM4 |
| DDM/DOM | Supported |
| Commercial Temperature Range | 0 to 70°C (32 to 158°F) |
| Protocols | IEEE 802.3cd, OIF-CEI-04.0, QSFP-DD MSA,QSFP-DD-CMIS-rev4p0 |
| Inbuilt FEC | No |
| Application | 8x 50G-PAM4 |
The listed modulation format is PAM4. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.
At 100m (328ft), QDD-400-AOC100M should be planned as an extended equipment-room connection rather than a short in-rack jumper. Mark the complete vertical and horizontal route before installation, including every manager the cable will actually pass through. Support the integrated optical cable and both optical engines along that path and keep both ends free from pull loads. The next shorter verified assembly is QDD-400-AOC70M at 70m (230ft), which is the better comparison when the managed route leaves substantial unused cable.
QDD-400-AOC100M is the longest of 13 verified length options in this family. Compared with QDD-400-AOC70M at 70m (230ft), it provides 30m of additional reach for a longer vertical drop, a wider rack or an adjacent-cabinet route. Confirm that the complete path requires this length, because unused slack still needs supported, bend-safe storage.
Check three layers before deployment: the host must accept the cable identification, the port must support the stated aggregate rate, and the lane configuration must match the attached interfaces. On breakout hardware, also confirm channelization and the mapping of every branch. These checks are particularly important when similar-looking ports operate at different speeds or under different firmware settings. For this assembly, the minimum bend radius is 30mm; the stated power consumption is 8W Per End; the jacket material is OFNP.
The rated power consumption is 8W Per End. Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.
This assembly uses OFNP jacket, minimum bend radius 30mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.
The intended application is 8x 50G-PAM4. Listed interface and protocol references include IEEE 802.3cd, OIF-CEI-04.0, QSFP-DD MSA,QSFP-DD-CMIS-rev4p0. Confirm that the host firmware and port configuration support the same operating mode.
The optical engines and fiber are permanently integrated into this AOC. There are no detachable optical modules to clean or exchange. Handle the complete assembly by its connector housings and cable, and keep both ends matched to the same interface specification.
Specify the OEM part number and fixed length, then provide the intended host configuration if the link uses channelized or breakout ports. Separate part numbers should be used for separate lengths. This gives the compatibility review enough information to check both the physical assembly and the intended operating mode. Quantity and any labeling instructions should be attached specifically to QDD-400-AOC100M.
The verification process combines digital identification with a live link test and diagnostic observation. Host model, hardware revision and software release are useful inputs because qualification behavior can change between platform generations; those details allow platform-specific requirements to be reviewed before the cable is packed. The check includes receive activity and diagnostic indications, followed by a final inspection of both ends.
Available stock is generally dispatched within one to three working days after order confirmation, with production lead times advised for larger quantities. Worldwide courier services are available, with air or sea freight for consolidated shipments; freight-collect delivery and coordination with a customer’s logistics provider can be arranged.
Functional inspection covers identification, link establishment and the condition of both connector assemblies. The cable is then protected against dust and connector damage and packed without sharp bends. Labels can include the customer reference and host-platform note when requested for a controlled deployment. Volume orders can include customer references on the labels and carton list.
No. It is an HT-manufactured compatible alternative for equipment that specifies Cisco QDD-400-AOC100M.
No. This is one complete direct-attach assembly. The ends are not detachable modules and should not be separated from the cable.
No. Use a supported, bend-safe service loop and observe the listed minimum bend radius. Do not crease the cable or tighten ties around the connector boots.
Not necessarily. Both hosts must support the stated rate, identification, lane mapping and any required breakout configuration; mechanical compatibility alone is insufficient.