The QFX-QSFP-DAC-7MA compatible assembly addresses a specific interoperability requirement: Juniper Networks host identification on a 40G DAC link measuring 7m (23ft). Its interface configuration is QSFP+ to QSFP+. This page explains the physical product, port-configuration checks and related part numbers so selection does not rely on connector appearance alone.
OEM Part Number: QFX-QSFP-DAC-7MAHT Part Number: QFX-QSFP-DAC-7MA
| HT Part Number | QFX-QSFP-DAC-7MA |
|---|---|
| Juniper Networks Compatible | QFX-QSFP-DAC-7MA |
| Manufacturer | HT |
| Connector Type | QSFP+ to QSFP+ |
| Max Data Rate | 40Gbps |
| Minimum Bend Radius | 37.5mm |
| Wire AWG | 26AWG |
| Cable Length | 7m (22.97ft) |
| Jacket Material | PVC (OFNR) |
| Temperature | 0 to 70°C (32 to 158°F) |
| Protocols | 40G InfiniBand 8x DDR, 4x QDR, 10G/40Gigabit Ethernet, Fibre Channel |
Juniper platform documentation distinguishes straight QSFP28 DAC or AOC connections from DACBO and AOCBO breakout operation. On channelized systems, the host port must be configured for the required breakout mode. Match this HT compatible cable to the exact Juniper part number and the intended platform configuration.
A passive DAC has no separate optical conversion stage. Its low-power, low-latency operation is useful for short equipment links, but the assembly must remain within the length and signaling mode accepted by both hosts.
Longer assemblies require disciplined cable dressing. For QFX-QSFP-DAC-7MA at 7m (23ft), use the intended managers rather than a diagonal route across the rack, and leave enough space to release each connector. Any service allowance should be loose and supported, with the complete copper assembly and both connector housings protected throughout the path. The next verified reach is QFX-QSFP-DAC-10MA at 10m (33ft), but selecting it before measuring the route would introduce additional slack to support.
QFX-QSFP-DAC-7MA is the shortest of 2 verified length options in this family. It is the preferred choice when the port positions are close and cable slack must be kept to a minimum. The next option is QFX-QSFP-DAC-10MA at 10m (33ft), adding 3m for a less direct routing path; selecting it unnecessarily would leave more cable to dress.
Check three layers before deployment: the host must accept the cable identification, the port must support the stated aggregate rate, and the lane configuration must match the attached interfaces. On breakout hardware, also confirm channelization and the mapping of every branch. These checks are particularly important when similar-looking ports operate at different speeds or under different firmware settings. For this assembly, the listed conductor specification is 26AWG; the minimum bend radius is 37.5mm; the jacket material is PVC (OFNR).
This assembly uses 26AWG conductors, PVC (OFNR) jacket, minimum bend radius 37.5mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.
The intended application is determined by the host interface and protocol support. Listed interface and protocol references include 40G InfiniBand 8x DDR, 4x QDR, 10G/40Gigabit Ethernet, Fibre Channel. Confirm that the host firmware and port configuration support the same operating mode.
Specify the OEM part number and fixed length, then provide the intended host configuration if the link uses channelized or breakout ports. Separate part numbers should be used for separate lengths. This gives the compatibility review enough information to check both the physical assembly and the intended operating mode. This page’s fixed configuration is 7m (23ft); another length must be quoted under its corresponding part number.
The verification process combines digital identification with a live link test and diagnostic observation. Host model, hardware revision and software release are useful inputs because qualification behavior can change between platform generations; those details allow platform-specific requirements to be reviewed before the cable is packed. Where supported by the host, link stability and diagnostic indications are reviewed together with the established link.
Available stock is generally dispatched within one to three working days after order confirmation, with production lead times advised for larger quantities. Worldwide courier services are available, with air or sea freight for consolidated shipments; freight-collect delivery and coordination with a customer’s logistics provider can be arranged.
Functional inspection covers identification, link establishment and the condition of both connector assemblies. The cable is then protected against dust and connector damage and packed without sharp bends. Labels can include the customer reference and host-platform note when requested for a controlled deployment. Standard protective packing is used by default, with project documentation arranged when requested.
No. It is an HT-manufactured compatible alternative for equipment that specifies Juniper Networks QFX-QSFP-DAC-7MA.
No. Use a supported, bend-safe service loop and observe the listed minimum bend radius. Do not crease the cable or tighten ties around the connector boots.
Not necessarily. Both hosts must support the stated rate, identification, lane mapping and any required breakout configuration; mechanical compatibility alone is insufficient.
Provide the equipment manufacturer, model, port type, hardware revision and software release, together with the OEM reference, required length and quantity.