
The QSFP-DD-200G-AOC-50M164FT compatible assembly addresses a specific interoperability requirement: Generic host identification on a 200G AOC link measuring 50m (164ft). Its interface configuration is QSFP-DD. This page explains the physical product, port-configuration checks and related part numbers so selection does not rely on connector appearance alone.
OEM Part Number: QSFP-DD-200G-AOC-50M164FTHT Part Number: QSFP-DD-200G-AOC-50M164FT
| HT Part Number | QSFP-DD-200G-AOC-50M164FT |
|---|---|
| Manufacturer | HT |
| Form Factor | QSFP-DD |
| Max. Data Rate | 200Gbps |
| Cable Length | 50m (164ft) |
| Cable Type | OM3 |
| Wavelength | 850nm |
| Minimum Bend Radius | 30mm |
| Transmitter Type | VCSEL |
| Receiver Type | PIN |
| Max. Power Consumption | 4W Per End |
| Jacket Material | OFNR |
| FEC | Supported |
| Modulation Format | NRZ |
| Protocols | QSFP-DD MSA V5.0, CMIS V4.0 |
| Commercial Temperature Range | 0 to 70°C (32 to 158°F) |
| Application | Ethernet |
The listed modulation format is NRZ. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.
Check three layers before deployment: the host must accept the cable identification, the port must support the stated aggregate rate, and the lane configuration must match the attached interfaces. On breakout hardware, also confirm channelization and the mapping of every branch. These checks are particularly important when similar-looking ports operate at different speeds or under different firmware settings. For this assembly, the minimum bend radius is 30mm; the stated power consumption is 4W Per End; the jacket material is OFNR.
The rated power consumption is 4W Per End. Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.
This assembly uses OFNR jacket, minimum bend radius 30mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.
The intended application is Ethernet. Listed interface and protocol references include QSFP-DD MSA V5.0, CMIS V4.0. Confirm that the host firmware and port configuration support the same operating mode.
The optical engines and fiber are permanently integrated into this AOC. There are no detachable optical modules to clean or exchange. Handle the complete assembly by its connector housings and cable, and keep both ends matched to the same interface specification.
Measure twice before deploying this 50m (164ft) cable: once along the planned route and again after accounting for service access. The objective is adequate reach without a concealed surplus. Support the integrated optical cable and both optical engines, preserve front-panel clearance and check that nearby power cords or sharp hardware cannot damage the jacket. Within this family, QSFP-DD-200G-AOC-30M98FT is shorter at 30m (98ft), while QSFP-DD-200G-AOC-70M230FT is the next longer choice at 70m (230ft); comparing those two boundaries helps avoid both tension and unnecessary slack.
QSFP-DD-200G-AOC-50M164FT occupies the middle of this family between QSFP-DD-200G-AOC-30M98FT at 30m (98ft) and QSFP-DD-200G-AOC-70M230FT at 70m (230ft). It adds 20m over the shorter option for extra routing clearance, while the next longer version adds another 20m. Measure the managed path and choose this version when its reach is sufficient without creating the slack associated with the longer assembly.
Specify the OEM part number and fixed length, then provide the intended host configuration if the link uses channelized or breakout ports. Separate part numbers should be used for separate lengths. This gives the compatibility review enough information to check both the physical assembly and the intended operating mode. This page’s fixed configuration is 50m (164ft); another length must be quoted under its corresponding part number.
The verification process combines digital identification with a live link test and diagnostic observation. Host model, hardware revision and software release are useful inputs because qualification behavior can change between platform generations; those details allow platform-specific requirements to be reviewed before the cable is packed. Both connectors are examined before the operating test, which includes receive activity and diagnostic indications.
Available stock is generally dispatched within one to three working days after order confirmation, with production lead times advised for larger quantities. Worldwide courier services are available, with air or sea freight for consolidated shipments; freight-collect delivery and coordination with a customer’s logistics provider can be arranged.
Functional inspection covers identification, link establishment and the condition of both connector assemblies. The cable is then protected against dust and connector damage and packed without sharp bends. Labels can include the customer reference and host-platform note when requested for a controlled deployment. Neutral packaging and customer-specific packing documentation are available on request.
No. It is manufactured by HT under our own manufacturer identity.
Not necessarily. Both hosts must support the stated rate, identification, lane mapping and any required breakout configuration; mechanical compatibility alone is insufficient.
Provide the equipment manufacturer, model, port type, hardware revision and software release, together with the OEM reference, required length and quantity.
Protect both connector ends, keep the cable in a loose bend-safe coil and retain its part-number label so the length and compatibility identity remain traceable.