
Use this 0.5m (2ft) DAC cable for hosts expecting Generic QSFP-DD to 8x SFP28-200G-DAC-0.5M2FT and a 200G direct-attached interface. The assembly uses QSFP-DD to 8x SFP28; lane, protocol and breakout considerations are documented alongside the verified table. Every alternative length remains a separate order code with its own technical page.
OEM Part Number: QSFP-DD to 8x SFP28-200G-DAC-0.5M2FTHT Part Number: QSFP-DD to 8x SFP28-200G-DAC-0.5M2FT
| HT Part Number | QSFP-DD to 8x SFP28-200G-DAC-0.5M2FT |
|---|---|
| Manufacturer | HT |
| Form Factor | QSFP-DD to 8x SFP28 |
| Max. Data Rate | 200Gbps |
| Media | Copper |
| Cable Type | Passive Breakout DAC |
| Minimum Bend Radius | 20.5mm |
| Wire AWG | 30AWG |
| Cable Length | 0.5m (2ft) |
| Jacket Material | PVC (OFNR) |
| Max. Power Consumption | 0.1W (QSFP-DD End)0.1W (SFP28 Per End) |
| Modulation Format | QSFP-DD-8x 25G-NRZSFP28-25G-NRZ |
| DDM/DOM | Not Supported |
| Commercial TemperatureRange | 0 to 70°C (32 to 158°F) |
| Protocols | QSFP-DD MSA, SFF-8432, IEEE 802.3bs-200GAUI-8, IEEE802.3by-25GAUI, CMIS 4.0, SFF-8472 |
The listed modulation format is QSFP-DD-8x 25G-NRZSFP28-25G-NRZ. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.
Check three layers before deployment: the host must accept the cable identification, the port must support the stated aggregate rate, and the lane configuration must match the attached interfaces. On breakout hardware, also confirm channelization and the mapping of every branch. These checks are particularly important when similar-looking ports operate at different speeds or under different firmware settings. For this assembly, the listed conductor specification is 30AWG; the minimum bend radius is 20.5mm; the stated power consumption is 0.1W (QSFP-DD End)0.1W (SFP28 Per End); the jacket material is PVC (OFNR).
The rated power consumption is 0.1W (QSFP-DD End)0.1W (SFP28 Per End). Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.
This assembly uses 30AWG conductors, PVC (OFNR) jacket, minimum bend radius 20.5mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.
The intended application is determined by the host interface and protocol support. Listed interface and protocol references include QSFP-DD MSA, SFF-8432, IEEE 802.3bs-200GAUI-8, IEEE802.3by-25GAUI, CMIS 4.0, SFF-8472. Confirm that the host firmware and port configuration support the same operating mode.
The QSFP-DD to 8x SFP28 configuration divides the high-speed interface into multiple lower-speed connections. Verify the upstream lane assignment, downstream port speeds and breakout setting on the host before connecting the assembly. Each branch must attach to the correct remote interface.
A passive DAC has no separate optical conversion stage. Its low-power, low-latency operation is useful for short equipment links, but the assembly must remain within the length and signaling mode accepted by both hosts.
The 0.5m (2ft) length is suited to closely aligned ports where excessive slack would obstruct airflow or complicate dressing. Measure the actual port-to-port path before choosing QSFP-DD to 8x SFP28-200G-DAC-0.5M2FT; even a short assembly must retain the specified bend radius and should never be pulled tight behind the equipment.
QSFP-DD to 8x SFP28-200G-DAC-0.5M2FT is the shortest of 6 verified length options in this family. It is the preferred choice when the port positions are close and cable slack must be kept to a minimum. The next option is QSFP-DD to 8x SFP28-200G-DAC-1M3FT at 1m (3ft), adding 0.5m for a less direct routing path; selecting it unnecessarily would leave more cable to dress.
Specify the OEM part number and fixed length, then provide the intended host configuration if the link uses channelized or breakout ports. Separate part numbers should be used for separate lengths. This gives the compatibility review enough information to check both the physical assembly and the intended operating mode. Keep QSFP-DD to 8x SFP28-200G-DAC-0.5M2FT associated with 0.5m (2ft) throughout the order and receiving record.
The verification process combines digital identification with a live link test and diagnostic observation. Host model, hardware revision and software release are useful inputs because qualification behavior can change between platform generations; those details allow platform-specific requirements to be reviewed before the cable is packed. Both connectors are examined before the operating test, which includes link stability and diagnostic indications.
Available stock is generally dispatched within one to three working days after order confirmation, with production lead times advised for larger quantities. Worldwide courier services are available, with air or sea freight for consolidated shipments; freight-collect delivery and coordination with a customer’s logistics provider can be arranged.
Functional inspection covers identification, link establishment and the condition of both connector assemblies. The cable is then protected against dust and connector damage and packed without sharp bends. Labels can include the customer reference and host-platform note when requested for a controlled deployment. Volume orders can include customer references on the labels and carton list.
No. It is manufactured by HT under our own manufacturer identity.
Only where both hosts explicitly support the complete interface and compatibility arrangement. Document each end and select the appropriate brand-specific product when required.
No. QSFP-DD to 8x SFP28-200G-DAC-0.5M2FT refers here to 0.5m (2ft). Every other verified length has a separate part number and page in the length list.
No. This is one complete direct-attach assembly. The ends are not detachable modules and should not be separated from the cable.