Philippines Fiber Optics

Connect the people, connect the world ...

Fiber Optic Cables

QSFP-DD to 8x SFP56-400G-DAC-1.5M5FT 400G QSFP-DD 8 x 50G PAM4 to 8 x 50G SFP56 50G PAM4 Passive Copper Breakout Cable, 1.5m (5ft)

QSFP-DD to 8x SFP56-400G-DAC-1.5M5FT 400G QSFP-DD 8 x 50G PAM4 to 8 x 50G SFP56 50G PAM4 Passive Copper Breakout Cable, 1.5m (5ft)

Use this 1.5m (5ft) DAC cable for hosts expecting Generic QSFP-DD to 8x SFP56-400G-DAC-1.5M5FT and a 400G direct-attached interface. The assembly uses QSFP-DD to 8x SFP56; lane, protocol and breakout considerations are documented alongside the verified table. Every alternative length remains a separate order code with its own technical page.

OEM Part Number: QSFP-DD to 8x SFP56-400G-DAC-1.5M5FTHT Part Number: QSFP-DD to 8x SFP56-400G-DAC-1.5M5FT

Product Highlights

  • HT-manufactured DAC assembly in 1.5m (5ft)
  • 400G connectivity at 400Gbps
  • Interface configuration: QSFP-DD to 8x SFP56
  • Fixed length and part number: 1.5m (5ft), QSFP-DD to 8x SFP56-400G-DAC-1.5M5FT
  • Cable construction: Passive Breakout DAC
  • Conductor specification: 30AWG
  • Maximum power consumption: 0.1W (QSFP-DD End)0.1W (SFP56 Per End)
  • Minimum bend radius: 33.5mm

Specifications

HT Part NumberQSFP-DD to 8x SFP56-400G-DAC-1.5M5FT
ManufacturerHT
Form FactorQSFP-DD to 8x SFP56
Max. Data Rate400Gbps
MediaCopper
Cable TypePassive Breakout DAC
Minimum Bend Radius33.5mm
Wire AWG30AWG
Cable Length1.5m (5ft)
Jacket MaterialPVC (OFNR)
Max. Power Consumption0.1W (QSFP-DD End)0.1W (SFP56 Per End)
Modulation FormatQSFP-DD-8x 50G-PAM4SFP56-50G-PAM4
DDM/DOMNot Supported
Commercial TemperatureRange0 to 70°C (32 to 158°F)
ProtocolsQSFP-DD MSA, SFF-8432, IEEE 802.3bs-400GAUI-8, IEEE802.3cd-50GAUI-1, CMIS 4.0, SFF-8472

Signal and Lane Configuration

The listed modulation format is QSFP-DD-8x 50G-PAM4SFP56-50G-PAM4. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.

Interoperability and Configuration Checks

Check three layers before deployment: the host must accept the cable identification, the port must support the stated aggregate rate, and the lane configuration must match the attached interfaces. On breakout hardware, also confirm channelization and the mapping of every branch. These checks are particularly important when similar-looking ports operate at different speeds or under different firmware settings. For this assembly, the listed conductor specification is 30AWG; the minimum bend radius is 33.5mm; the stated power consumption is 0.1W (QSFP-DD End)0.1W (SFP56 Per End); the jacket material is PVC (OFNR).

Power and Thermal Planning

The rated power consumption is 0.1W (QSFP-DD End)0.1W (SFP56 Per End). Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.

Cable Construction and Routing

This assembly uses 30AWG conductors, PVC (OFNR) jacket, minimum bend radius 33.5mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.

Network and Protocol Considerations

The intended application is determined by the host interface and protocol support. Listed interface and protocol references include QSFP-DD MSA, SFF-8432, IEEE 802.3bs-400GAUI-8, IEEE802.3cd-50GAUI-1, CMIS 4.0, SFF-8472. Confirm that the host firmware and port configuration support the same operating mode.

Breakout Port Mapping

The QSFP-DD to 8x SFP56 configuration divides the high-speed interface into multiple lower-speed connections. Verify the upstream lane assignment, downstream port speeds and breakout setting on the host before connecting the assembly. Each branch must attach to the correct remote interface.

Passive Copper Operation

A passive DAC has no separate optical conversion stage. Its low-power, low-latency operation is useful for short equipment links, but the assembly must remain within the length and signaling mode accepted by both hosts.

Length Selection and Installation Planning

The additional half metre beyond a one-metre assembly gives QSFP-DD to 8x SFP56-400G-DAC-1.5M5FT useful routing flexibility when the ports are not directly aligned. It can accommodate a different rack unit or a short service loop, but excess cable should be dressed loosely rather than folded into a tight coil.

Position Within the Length Range

QSFP-DD to 8x SFP56-400G-DAC-1.5M5FT occupies the middle of this family between QSFP-DD to 8x SFP56-400G-DAC-1M3FT at 1m (3ft) and QSFP-DD to 8x SFP56-400G-DAC-2M7FT at 2m (7ft). It adds 0.5m over the shorter option for extra routing clearance, while the next longer version adds another 0.5m. Measure the managed path and choose this version when its reach is sufficient without creating the slack associated with the longer assembly.

Ordering Information

Specify the OEM part number and fixed length, then provide the intended host configuration if the link uses channelized or breakout ports. Separate part numbers should be used for separate lengths. This gives the compatibility review enough information to check both the physical assembly and the intended operating mode. Quantity and any labeling instructions should be attached specifically to QSFP-DD to 8x SFP56-400G-DAC-1.5M5FT.

Generic Compatibility and Factory Testing

The verification process combines digital identification with a live link test and diagnostic observation. Host model, hardware revision and software release are useful inputs because qualification behavior can change between platform generations; those details allow platform-specific requirements to be reviewed before the cable is packed. Where supported by the host, link stability and diagnostic indications are reviewed together with the established link.

Shipping and Lead Time

Standard configurations normally ship within one to three working days, while production quantities are confirmed with the order. Delivery can be arranged by courier, air freight or sea freight, and goods may instead be handed to an appointed forwarder or shipped on the customer’s courier account.

Quality Assurance and Packaging

Functional inspection covers identification, link establishment and the condition of both connector assemblies. The cable is then protected against dust and connector damage and packed without sharp bends. Labels can include the customer reference and host-platform note when requested for a controlled deployment. Volume orders can include customer references on the labels and carton list.

Frequently Asked Questions

Is this an original equipment manufacturer cable?

No. It is manufactured by HT under our own manufacturer identity.

Can excess cable be folded into a compact bundle?

No. Use a supported, bend-safe service loop and observe the listed minimum bend radius. Do not crease the cable or tighten ties around the connector boots.

Will any matching connector operate at the same speed?

Not necessarily. Both hosts must support the stated rate, identification, lane mapping and any required breakout configuration; mechanical compatibility alone is insufficient.

What details assist a compatibility review?

Provide the equipment manufacturer, model, port type, hardware revision and software release, together with the OEM reference, required length and quantity.


About us

China Factory:No 168 Golden Ground Industrial Area;
Philippines Address:Makati City,Metro Manila, Philippines

Products catalogues

For products catalogue/data sheets or any general inquiry, please email info@huihongfiber.com and we will reply with details.

Customer Support

For customer support, please email sales@huihongfiber.com; our support team will get back to you as soon as possible.