QSFP-DD to QSFP-DD-400G-AEC-1M3FT 400G QSFP-DD 8 x 50G PAM4 Active Electrical Cable, 1m (3ft)

QSFP-DD to QSFP-DD-400G-AEC-1M3FT 400G QSFP-DD 8 x 50G PAM4 Active Electrical Cable, 1m (3ft)

Use this 1m (3ft) AEC cable for hosts expecting Generic QSFP-DD to QSFP-DD-400G-AEC-1M3FT and a 400G direct-attached interface. The assembly uses QSFP-DD to QSFP-DD; lane, protocol and breakout considerations are documented alongside the verified table. Every alternative length remains a separate order code with its own technical page.

OEM Part Number: QSFP-DD to QSFP-DD-400G-AEC-1M3FTHT Part Number: QSFP-DD to QSFP-DD-400G-AEC-1M3FT

Product Highlights

  • HT-manufactured AEC assembly in 1m (3ft)
  • 400G connectivity at 400Gbps
  • Interface configuration: QSFP-DD to QSFP-DD
  • Fixed length and part number: 1m (3ft), QSFP-DD to QSFP-DD-400G-AEC-1M3FT
  • Cable construction: Active DAC (AEC)
  • Conductor specification: 32AWG
  • Maximum power consumption: 10W Per End
  • Minimum bend radius: 26.5mm

Specifications

HT Part NumberQSFP-DD to QSFP-DD-400G-AEC-1M3FT
ManufacturerHT
Form FactorQSFP-DD to QSFP-DD
Max. Data Rate400Gbps
MediaCopper
Cable TypeActive DAC (AEC)
Minimum Bend Radius26.5mm
Wire AWG32AWG
Cable Length1m (3ft)
Jacket MaterialPET
Max. Power Consumption10W Per End
Modulation Format8x 50G-PAM4
DDM/DOMSupported
Commercial Temperature Range0 to 70°C (32 to 158°F)
ProtocolsQSFP-DD MSA, IEEE 802.3cd, CMIS 5.0

Signal and Lane Configuration

The listed modulation format is 8x 50G-PAM4. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.

Length Selection and Installation Planning

At 1m (3ft), QSFP-DD to QSFP-DD-400G-AEC-1M3FT is a practical choice for direct connections within one rack. Route the cable along the intended management path rather than pulling it diagonally across adjacent connectors, and leave enough clearance for insertion, removal and front-panel airflow.

Position Within the Length Range

QSFP-DD to QSFP-DD-400G-AEC-1M3FT is the shortest of 4 verified length options in this family. It is the preferred choice when the port positions are close and cable slack must be kept to a minimum. The next option is QSFP-DD to QSFP-DD-400G-AEC-2M7FT at 2m (7ft), adding 1m for a less direct routing path; selecting it unnecessarily would leave more cable to dress.

Interoperability and Configuration Checks

Check three layers before deployment: the host must accept the cable identification, the port must support the stated aggregate rate, and the lane configuration must match the attached interfaces. On breakout hardware, also confirm channelization and the mapping of every branch. These checks are particularly important when similar-looking ports operate at different speeds or under different firmware settings. For this assembly, the listed conductor specification is 32AWG; the minimum bend radius is 26.5mm; the stated power consumption is 10W Per End; the jacket material is PET.

Power and Thermal Planning

The rated power consumption is 10W Per End. Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.

Cable Construction and Routing

This assembly uses 32AWG conductors, PET jacket, minimum bend radius 26.5mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.

Network and Protocol Considerations

The intended application is determined by the host interface and protocol support. Listed interface and protocol references include QSFP-DD MSA, IEEE 802.3cd, CMIS 5.0. Confirm that the host firmware and port configuration support the same operating mode.

Ordering Information

Specify the OEM part number and fixed length, then provide the intended host configuration if the link uses channelized or breakout ports. Separate part numbers should be used for separate lengths. This gives the compatibility review enough information to check both the physical assembly and the intended operating mode. This page’s fixed configuration is 1m (3ft); another length must be quoted under its corresponding part number.

Generic Compatibility and Factory Testing

The verification process combines digital identification with a live link test and diagnostic observation. Host model, hardware revision and software release are useful inputs because qualification behavior can change between platform generations; those details allow platform-specific requirements to be reviewed before the cable is packed. The check includes link stability and diagnostic indications, followed by a final inspection of both ends.

Shipping and Lead Time

Standard configurations normally ship within one to three working days, while production quantities are confirmed with the order. International express, air cargo and sea freight can be selected according to destination and carton volume; customer courier accounts and nominated forwarders are also accepted.

Quality Assurance and Packaging

Functional inspection covers identification, link establishment and the condition of both connector assemblies. The cable is then protected against dust and connector damage and packed without sharp bends. Labels can include the customer reference and host-platform note when requested for a controlled deployment. Volume orders can include customer references on the labels and carton list.

Frequently Asked Questions

Is this an original equipment manufacturer cable?

No. It is manufactured by HT under our own manufacturer identity.

Can different brands be connected with the same assembly?

Only where both hosts explicitly support the complete interface and compatibility arrangement. Document each end and select the appropriate brand-specific product when required.

Does this order code cover multiple lengths?

No. QSFP-DD to QSFP-DD-400G-AEC-1M3FT refers here to 1m (3ft). Every other verified length has a separate part number and page in the length list.

Are separate transceivers or patch leads required?

No. This is one complete direct-attach assembly. The ends are not detachable modules and should not be separated from the cable.


About us

China Factory:No 168 Golden Ground Industrial Area;
Philippines Address:Makati City,Metro Manila, Philippines

Products catalogues

For products catalogue/data sheets or any general inquiry, please email info@huihongfiber.com and we will reply with details.

Customer Support

For customer support, please email sales@huihongfiber.com; our support team will get back to you as soon as possible.