Philippines Fiber Optics

Connect the people, connect the world ...

Fiber Optic Cables

QSFP-DD to QSFP-DD-800G-ACC-0.5M2FT 800G QSFP-DD 8 x 100G PAM4 Active Copper Twinax Cable, 0.5m (2ft)

QSFP-DD to QSFP-DD-800G-ACC-0.5M2FT 800G QSFP-DD 8 x 100G PAM4 Active Copper Twinax Cable, 0.5m (2ft)

The QSFP-DD to QSFP-DD-800G-ACC-0.5M2FT compatible assembly addresses a specific interoperability requirement: Generic host identification on a 800G ACC link measuring 0.5m (2ft). Its interface configuration is QSFP-DD to QSFP-DD. This page explains the physical product, port-configuration checks and related part numbers so selection does not rely on connector appearance alone.

OEM Part Number: QSFP-DD to QSFP-DD-800G-ACC-0.5M2FTHT Part Number: QSFP-DD to QSFP-DD-800G-ACC-0.5M2FT

Product Highlights

  • HT-manufactured ACC assembly in 0.5m (2ft)
  • 800G connectivity at 800Gbps
  • Interface configuration: QSFP-DD to QSFP-DD
  • Fixed length and part number: 0.5m (2ft), QSFP-DD to QSFP-DD-800G-ACC-0.5M2FT
  • Cable construction: Active DAC (ACC)
  • Conductor specification: 30AWG
  • Maximum power consumption: ≤1.2W
  • Minimum bend radius: 34.5mm

Specifications

HT Part NumberQSFP-DD to QSFP-DD-800G-ACC-0.5M2FT
Form FactorQSFP-DD to QSFP-DD
MediaCopper
Max Data Rate800Gbps
Cable TypeActive DAC (ACC)
Cable Length0.5m (2ft)
Minimum Bend Radius34.5mm
Wire AWG30AWG
Modulation FormatPAM4
Power Consumption≤1.2W
Jacket MaterialPVC (OFNR)
Commercial Temperature0 to 70°C (32 to 158°F)
ProtocolsQSFP-DD MSA Rev. 5.0, CMIS Rev 4.0, SFF 8417, IEEE 802.3ck
ManufacturerHT

Signal and Lane Configuration

The listed modulation format is PAM4. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.

Length Selection and Installation Planning

The 0.5m (2ft) length is suited to closely aligned ports where excessive slack would obstruct airflow or complicate dressing. Measure the actual port-to-port path before choosing QSFP-DD to QSFP-DD-800G-ACC-0.5M2FT; even a short assembly must retain the specified bend radius and should never be pulled tight behind the equipment.

Position Within the Length Range

QSFP-DD to QSFP-DD-800G-ACC-0.5M2FT is the shortest of 5 verified length options in this family. It is the preferred choice when the port positions are close and cable slack must be kept to a minimum. The next option is QSFP-DD to QSFP-DD-800G-ACC-1M3FT at 1m (3ft), adding 0.5m for a less direct routing path; selecting it unnecessarily would leave more cable to dress.

Interoperability and Configuration Checks

Check three layers before deployment: the host must accept the cable identification, the port must support the stated aggregate rate, and the lane configuration must match the attached interfaces. On breakout hardware, also confirm channelization and the mapping of every branch. These checks are particularly important when similar-looking ports operate at different speeds or under different firmware settings. For this assembly, the listed conductor specification is 30AWG; the minimum bend radius is 34.5mm; the stated power consumption is ≤1.2W; the jacket material is PVC (OFNR).

Power and Thermal Planning

The rated power consumption is ≤1.2W. Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.

Cable Construction and Routing

This assembly uses 30AWG conductors, PVC (OFNR) jacket, minimum bend radius 34.5mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.

Network and Protocol Considerations

The intended application is determined by the host interface and protocol support. Listed interface and protocol references include QSFP-DD MSA Rev. 5.0, CMIS Rev 4.0, SFF 8417, IEEE 802.3ck. Confirm that the host firmware and port configuration support the same operating mode.

Ordering Information

Specify the OEM part number and fixed length, then provide the intended host configuration if the link uses channelized or breakout ports. Separate part numbers should be used for separate lengths. This gives the compatibility review enough information to check both the physical assembly and the intended operating mode. Keep QSFP-DD to QSFP-DD-800G-ACC-0.5M2FT associated with 0.5m (2ft) throughout the order and receiving record.

Generic Compatibility and Factory Testing

The verification process combines digital identification with a live link test and diagnostic observation. Host model, hardware revision and software release are useful inputs because qualification behavior can change between platform generations; those details allow platform-specific requirements to be reviewed before the cable is packed. Both connectors are examined before the operating test, which includes link stability and diagnostic indications.

Shipping and Lead Time

Standard configurations normally ship within one to three working days, while production quantities are confirmed with the order. Worldwide courier services are available, with air or sea freight for consolidated shipments; freight-collect delivery and coordination with a customer’s logistics provider can be arranged.

Quality Assurance and Packaging

Functional inspection covers identification, link establishment and the condition of both connector assemblies. The cable is then protected against dust and connector damage and packed without sharp bends. Labels can include the customer reference and host-platform note when requested for a controlled deployment. Neutral packaging and customer-specific packing documentation are available on request.

Frequently Asked Questions

Is this an original equipment manufacturer cable?

No. It is manufactured by HT under our own manufacturer identity.

Are separate transceivers or patch leads required?

No. This is one complete direct-attach assembly. The ends are not detachable modules and should not be separated from the cable.

Can excess cable be folded into a compact bundle?

No. Use a supported, bend-safe service loop and observe the listed minimum bend radius. Do not crease the cable or tighten ties around the connector boots.

Will any matching connector operate at the same speed?

Not necessarily. Both hosts must support the stated rate, identification, lane mapping and any required breakout configuration; mechanical compatibility alone is insufficient.


About us

China Factory:No 168 Golden Ground Industrial Area;
Philippines Address:Makati City,Metro Manila, Philippines

Products catalogues

For products catalogue/data sheets or any general inquiry, please email info@huihongfiber.com and we will reply with details.

Customer Support

For customer support, please email sales@huihongfiber.com; our support team will get back to you as soon as possible.