Use this 1m (3ft) AEC cable for hosts expecting Generic QSFP112 to QSFP112-400G-AEC-1M3FT and a 400G direct-attached interface. The assembly uses QSFP112 to QSFP112; lane, protocol and breakout considerations are documented alongside the verified table. Every alternative length remains a separate order code with its own technical page.
OEM Part Number: QSFP112 to QSFP112-400G-AEC-1M3FTHT Part Number: QSFP112 to QSFP112-400G-AEC-1M3FT
| HT Part Number | QSFP112 to QSFP112-400G-AEC-1M3FT |
|---|---|
| Manufacturer | HT |
| Form Factor | QSFP112 to QSFP112 |
| Max. Data Rate | 400Gbps |
| Media | Copper |
| Cable Type | Active DAC (AEC) |
| Minimum Bend Radius | 26.5mm |
| Wire AWG | 32AWG |
| Cable Length | 1m (3ft) |
| Jacket Material | PET |
| Power Consumption | <8W Per End |
| Modulation Format | 4x 100G-PAM4 |
| DDM/DOM | Supported |
| Temperature Range | 0 to 70°C (32 to 158°F) |
| Protocols | QSFP112 MSA, IEEE 802.3ck 400GBase-CR4, CMIS 5.0 |
The listed modulation format is 4x 100G-PAM4. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.
The intended application is determined by the host interface and protocol support. Listed interface and protocol references include QSFP112 MSA, IEEE 802.3ck 400GBase-CR4, CMIS 5.0. Confirm that the host firmware and port configuration support the same operating mode.
At 1m (3ft), QSFP112 to QSFP112-400G-AEC-1M3FT is a practical choice for direct connections within one rack. Route the cable along the intended management path rather than pulling it diagonally across adjacent connectors, and leave enough clearance for insertion, removal and front-panel airflow.
QSFP112 to QSFP112-400G-AEC-1M3FT is the shortest of 3 verified length options in this family. It is the preferred choice when the port positions are close and cable slack must be kept to a minimum. The next option is QSFP112 to QSFP112-400G-AEC-2M7FT at 2m (7ft), adding 1m for a less direct routing path; selecting it unnecessarily would leave more cable to dress.
Check three layers before deployment: the host must accept the cable identification, the port must support the stated aggregate rate, and the lane configuration must match the attached interfaces. On breakout hardware, also confirm channelization and the mapping of every branch. These checks are particularly important when similar-looking ports operate at different speeds or under different firmware settings. For this assembly, the listed conductor specification is 32AWG; the minimum bend radius is 26.5mm; the stated power consumption is <8W Per End; the jacket material is PET.
The rated power consumption is <8W Per End. Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.
This assembly uses 32AWG conductors, PET jacket, minimum bend radius 26.5mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.
Specify the OEM part number and fixed length, then provide the intended host configuration if the link uses channelized or breakout ports. Separate part numbers should be used for separate lengths. This gives the compatibility review enough information to check both the physical assembly and the intended operating mode. Keep QSFP112 to QSFP112-400G-AEC-1M3FT associated with 1m (3ft) throughout the order and receiving record.
The verification process combines digital identification with a live link test and diagnostic observation. Host model, hardware revision and software release are useful inputs because qualification behavior can change between platform generations; those details allow platform-specific requirements to be reviewed before the cable is packed. Both connectors are examined before the operating test, which includes link stability and diagnostic indications.
Standard configurations normally ship within one to three working days, while production quantities are confirmed with the order. International express, air cargo and sea freight can be selected according to destination and carton volume; customer courier accounts and nominated forwarders are also accepted.
Functional inspection covers identification, link establishment and the condition of both connector assemblies. The cable is then protected against dust and connector damage and packed without sharp bends. Labels can include the customer reference and host-platform note when requested for a controlled deployment. Standard protective packing is used by default, with project documentation arranged when requested.
No. It is manufactured by HT under our own manufacturer identity.
Provide the equipment manufacturer, model, port type, hardware revision and software release, together with the OEM reference, required length and quantity.
Protect both connector ends, keep the cable in a loose bend-safe coil and retain its part-number label so the length and compatibility identity remain traceable.
Only where both hosts explicitly support the complete interface and compatibility arrangement. Document each end and select the appropriate brand-specific product when required.