Use this 10m (33ft) AOC cable for hosts expecting Brocade QSFP28-100G-AOC-10M and a 100G direct-attached interface. The assembly uses QSFP28 to QSFP28; lane, protocol and breakout considerations are documented alongside the verified table. Every alternative length remains a separate order code with its own technical page.
OEM Part Number: QSFP28-100G-AOC-10MHT Part Number: QSFP28-100G-AOC-10M
| HT Part Number | QSFP28-100G-AOC-10M |
|---|---|
| Brocade Compatible | QSFP28-100G-AOC-10M |
| Manufacturer | HT |
| Form Factor | QSFP28 to QSFP28 |
| Max Data Rate | 100Gbps |
| Minimum Bend Radius | 30mm |
| Cable Length | 10m (32.81ft) |
| Jacket Material | OFNP |
| Cable Type | Optical Cable |
| Receiver Type | PIN |
| Transmitter Type | VSCEL |
| Wavelength | 850nm |
| Power Consumption | <2.2W |
| MTBF | ≈50 Million Hours |
| Power supply | 3.3V |
| Commercial Temperature Range | 0 to 70°C (32 to 158°F) |
| Protocols | IEEE 802.3 bm, SFF-8665 |
| CDR (Clock and Data Recovery) | TX & RX Built-in CDR |
| Modulation Format | 4x 25G-NRZ to 4x 25G-NRZ |
| Application | 100G Ethernet |
The listed modulation format is 4x 25G-NRZ to 4x 25G-NRZ. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.
The optical engines and fiber are permanently integrated into this AOC. There are no detachable optical modules to clean or exchange. Handle the complete assembly by its connector housings and cable, and keep both ends matched to the same interface specification.
With 10m (33ft) available, the installer has more routing freedom but also more cable to control. Determine where any remaining service loop will be stored, preserve the stated bend radius and keep the loop away from sharp edges and hot exhaust. The integrated optical cable and both optical engines should remain accessible for inspection and removal. Within this family, QSFP28-100G-AOC-7M is shorter at 7m (23ft), while QSFP28-100G-AOC-15M is the next longer choice at 15m (49ft); comparing those two boundaries helps avoid both tension and unnecessary slack.
QSFP28-100G-AOC-10M occupies the middle of this family between QSFP28-100G-AOC-7M at 7m (23ft) and QSFP28-100G-AOC-15M at 15m (49ft). It adds 3m over the shorter option for extra routing clearance, while the next longer version adds another 5m. Measure the managed path and choose this version when its reach is sufficient without creating the slack associated with the longer assembly.
Check three layers before deployment: the host must accept the cable identification, the port must support the stated aggregate rate, and the lane configuration must match the attached interfaces. On breakout hardware, also confirm channelization and the mapping of every branch. These checks are particularly important when similar-looking ports operate at different speeds or under different firmware settings. For this assembly, the minimum bend radius is 30mm; the stated power consumption is <2.2W; the jacket material is OFNP.
The rated power consumption is <2.2W. Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.
This assembly uses OFNP jacket, minimum bend radius 30mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.
The intended application is 100G Ethernet. Listed interface and protocol references include IEEE 802.3 bm, SFF-8665. Confirm that the host firmware and port configuration support the same operating mode.
Specify the OEM part number and fixed length, then provide the intended host configuration if the link uses channelized or breakout ports. Separate part numbers should be used for separate lengths. This gives the compatibility review enough information to check both the physical assembly and the intended operating mode. Quantity and any labeling instructions should be attached specifically to QSFP28-100G-AOC-10M.
The verification process combines digital identification with a live link test and diagnostic observation. Host model, hardware revision and software release are useful inputs because qualification behavior can change between platform generations; those details allow platform-specific requirements to be reviewed before the cable is packed. The check includes receive activity and diagnostic indications, followed by a final inspection of both ends.
Available stock is generally dispatched within one to three working days after order confirmation, with production lead times advised for larger quantities. Worldwide courier services are available, with air or sea freight for consolidated shipments; freight-collect delivery and coordination with a customer’s logistics provider can be arranged.
Functional inspection covers identification, link establishment and the condition of both connector assemblies. The cable is then protected against dust and connector damage and packed without sharp bends. Labels can include the customer reference and host-platform note when requested for a controlled deployment. Volume orders can include customer references on the labels and carton list.
No. It is an HT-manufactured compatible alternative for equipment that specifies Brocade QSFP28-100G-AOC-10M.
No. QSFP28-100G-AOC-10M refers here to 10m (33ft). Every other verified length has a separate part number and page in the length list.
No. This is one complete direct-attach assembly. The ends are not detachable modules and should not be separated from the cable.
No. Use a supported, bend-safe service loop and observe the listed minimum bend radius. Do not crease the cable or tighten ties around the connector boots.