Use this 70m (230ft) AOC cable for hosts expecting Generic QSFP28-DD to Duplex-LC-200G-AOC-70M230FT and a 200G direct-attached interface. The assembly uses QSFP28-DD to Duplex-LC; lane, protocol and breakout considerations are documented alongside the verified table. Every alternative length remains a separate order code with its own technical page.
OEM Part Number: QSFP28-DD to Duplex-LC-200G-AOC-70M230FTHT Part Number: QSFP28-DD to Duplex-LC-200G-AOC-70M230FT
| HT Part Number | QSFP28-DD to Duplex-LC-200G-AOC-70M230FT |
|---|---|
| Manufacturer | HT |
| Connector Type | QSFP28-DD to Duplex-LC |
| Max Data Rate | 200Gbps |
| Minimum Bend Radius | 30mm |
| Cable Length | 70m (230ft) |
| Wavelength | 850nm |
| Cable Type | Optical Cable |
| Modulation Format | NRZ |
| Power Consumption | ≤3.47W |
| Power supply | 3.5V |
| Extend Temperature Range | -20°C to +85°C |
| Protocols | QSFP-DD MSA CMIS 4.0, IEEE 802.3bs 200G-SR8, IEEE 802.3by 25G-SR |
| Application | Ethernet, 5G Front Haul |
The listed modulation format is NRZ. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.
The intended application is Ethernet, 5G Front Haul. Listed interface and protocol references include QSFP-DD MSA CMIS 4.0, IEEE 802.3bs 200G-SR8, IEEE 802.3by 25G-SR. Confirm that the host firmware and port configuration support the same operating mode.
The QSFP28-DD to Duplex-LC configuration divides the high-speed interface into multiple lower-speed connections. Verify the upstream lane assignment, downstream port speeds and breakout setting on the host before connecting the assembly. Each branch must attach to the correct remote interface.
The optical engines and fiber are permanently integrated into this AOC. There are no detachable optical modules to clean or exchange. Handle the complete assembly by its connector housings and cable, and keep both ends matched to the same interface specification.
A 70m (230ft) run can remain tidy when its pathway and service allowance are planned together. Keep the integrated optical cable and both optical engines away from tight cable-tie pressure, verify bend control at changes of direction and ensure that neither port supports the assembly’s weight. Record the exact order code after acceptance. The next shorter verified assembly is QSFP28-DD to Duplex-LC-200G-AOC-50M164FT at 50m (164ft), which is the better comparison when the managed route leaves substantial unused cable.
QSFP28-DD to Duplex-LC-200G-AOC-70M230FT is the longest of 11 verified length options in this family. Compared with QSFP28-DD to Duplex-LC-200G-AOC-50M164FT at 50m (164ft), it provides 20m of additional reach for a longer vertical drop, a wider rack or an adjacent-cabinet route. Confirm that the complete path requires this length, because unused slack still needs supported, bend-safe storage.
Check three layers before deployment: the host must accept the cable identification, the port must support the stated aggregate rate, and the lane configuration must match the attached interfaces. On breakout hardware, also confirm channelization and the mapping of every branch. These checks are particularly important when similar-looking ports operate at different speeds or under different firmware settings. For this assembly, the minimum bend radius is 30mm; the stated power consumption is ≤3.47W.
The rated power consumption is ≤3.47W. Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.
This assembly uses minimum bend radius 30mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.
Specify the OEM part number and fixed length, then provide the intended host configuration if the link uses channelized or breakout ports. Separate part numbers should be used for separate lengths. This gives the compatibility review enough information to check both the physical assembly and the intended operating mode. Keep QSFP28-DD to Duplex-LC-200G-AOC-70M230FT associated with 70m (230ft) throughout the order and receiving record.
The verification process combines digital identification with a live link test and diagnostic observation. Host model, hardware revision and software release are useful inputs because qualification behavior can change between platform generations; those details allow platform-specific requirements to be reviewed before the cable is packed. The check includes receive activity and diagnostic indications, followed by a final inspection of both ends.
Available stock is generally dispatched within one to three working days after order confirmation, with production lead times advised for larger quantities. International express, air cargo and sea freight can be selected according to destination and carton volume; customer courier accounts and nominated forwarders are also accepted.
Functional inspection covers identification, link establishment and the condition of both connector assemblies. The cable is then protected against dust and connector damage and packed without sharp bends. Labels can include the customer reference and host-platform note when requested for a controlled deployment. Standard protective packing is used by default, with project documentation arranged when requested.
No. It is manufactured by HT under our own manufacturer identity.
No. Use a supported, bend-safe service loop and observe the listed minimum bend radius. Do not crease the cable or tighten ties around the connector boots.
Not necessarily. Both hosts must support the stated rate, identification, lane mapping and any required breakout configuration; mechanical compatibility alone is insufficient.
Provide the equipment manufacturer, model, port type, hardware revision and software release, together with the OEM reference, required length and quantity.