QSFP28 to 4 duplex LC-100G-AOC-25M82FT 100G QSFP28 4 x 25G NRZ to 4 Duplex LC 25G NRZ Active Optical Breakout Cable, 25m (82ft)

QSFP28 to 4 duplex LC-100G-AOC-25M82FT 100G QSFP28 4 x 25G NRZ to 4 Duplex LC 25G NRZ Active Optical Breakout Cable, 25m (82ft)

Use this 25m (82ft) AOC cable for hosts expecting Generic QSFP28 to 4 duplex LC-100G-AOC-25M82FT and a 100G direct-attached interface. The assembly uses QSFP28 to 4 duplex LC; lane, protocol and breakout considerations are documented alongside the verified table. Every alternative length remains a separate order code with its own technical page.

OEM Part Number: QSFP28 to 4 duplex LC-100G-AOC-25M82FTHT Part Number: QSFP28 to 4 duplex LC-100G-AOC-25M82FT

Product Highlights

  • HT-manufactured AOC assembly in 25m (82ft)
  • 100G connectivity at 100Gbps
  • Interface configuration: QSFP28 to 4 duplex LC
  • Fixed length and part number: 25m (82ft), QSFP28 to 4 duplex LC-100G-AOC-25M82FT
  • Cable construction: Breakout AOC
  • Maximum power consumption: 2.2W
  • Minimum bend radius: 20mm
  • Operating temperature: 0 to 70°C (32 to 158°F)

Specifications

HT Part NumberQSFP28 to 4 duplex LC-100G-AOC-25M82FT
ManufacturerHT
Form FactorQSFP28 to 4 duplex LC
Max. Data Rate100Gbps
Cable Length25m (82ft)
Cable TypeBreakout AOC
Wavelength850nm
Minimum Bend Radius20mm
Transmitter TypeVCSEL
Receiver TypePIN
Max. Power Consumption2.2W
Modulation FormatQSFP28-4x 25G-NRZ Duplex LC-1x 25G-NRZ
CDR (Clock and Data Recovery)TX & RX Built-in CDR
Jacket MaterialOFNP
DDM/DOMSupported
Commercial Temperature Range0 to 70°C (32 to 158°F)
ProtocolsSFF-8436, SFF-8431

Signal and Lane Configuration

The listed modulation format is QSFP28-4x 25G-NRZ Duplex LC-1x 25G-NRZ. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.

Integrated Optical Assembly

The optical engines and fiber are permanently integrated into this AOC. There are no detachable optical modules to clean or exchange. Handle the complete assembly by its connector housings and cable, and keep both ends matched to the same interface specification.

Length Selection and Installation Planning

The extended 25m (82ft) configuration gives QSFP28 to 4 duplex LC-100G-AOC-25M82FT a specific place in the family reach range. It should not be treated as a universal substitute for every shorter order code. Match it to a documented route, protect the integrated optical cable and both optical engines during handling and retain the part-number label for later maintenance. Within this family, QSFP28 to 4 duplex LC-100G-AOC-20M66FT is shorter at 20m (66ft), while QSFP28 to 4 duplex LC-100G-AOC-30M98FT is the next longer choice at 30m (98ft); comparing those two boundaries helps avoid both tension and unnecessary slack.

Position Within the Length Range

QSFP28 to 4 duplex LC-100G-AOC-25M82FT occupies the middle of this family between QSFP28 to 4 duplex LC-100G-AOC-20M66FT at 20m (66ft) and QSFP28 to 4 duplex LC-100G-AOC-30M98FT at 30m (98ft). It adds 5m over the shorter option for extra routing clearance, while the next longer version adds another 5m. Measure the managed path and choose this version when its reach is sufficient without creating the slack associated with the longer assembly.

Interoperability and Configuration Checks

Check three layers before deployment: the host must accept the cable identification, the port must support the stated aggregate rate, and the lane configuration must match the attached interfaces. On breakout hardware, also confirm channelization and the mapping of every branch. These checks are particularly important when similar-looking ports operate at different speeds or under different firmware settings. For this assembly, the minimum bend radius is 20mm; the stated power consumption is 2.2W; the jacket material is OFNP.

Power and Thermal Planning

The rated power consumption is 2.2W. Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.

Cable Construction and Routing

This assembly uses OFNP jacket, minimum bend radius 20mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.

Network and Protocol Considerations

The intended application is determined by the host interface and protocol support. Listed interface and protocol references include SFF-8436, SFF-8431. Confirm that the host firmware and port configuration support the same operating mode.

Breakout Port Mapping

The QSFP28 to 4 duplex LC configuration divides the high-speed interface into multiple lower-speed connections. Verify the upstream lane assignment, downstream port speeds and breakout setting on the host before connecting the assembly. Each branch must attach to the correct remote interface.

Ordering Information

Specify the OEM part number and fixed length, then provide the intended host configuration if the link uses channelized or breakout ports. Separate part numbers should be used for separate lengths. This gives the compatibility review enough information to check both the physical assembly and the intended operating mode. Keep QSFP28 to 4 duplex LC-100G-AOC-25M82FT associated with 25m (82ft) throughout the order and receiving record.

Generic Compatibility and Factory Testing

The verification process combines digital identification with a live link test and diagnostic observation. Host model, hardware revision and software release are useful inputs because qualification behavior can change between platform generations; those details allow platform-specific requirements to be reviewed before the cable is packed. The check includes receive activity and diagnostic indications, followed by a final inspection of both ends.

Shipping and Lead Time

Available stock is generally dispatched within one to three working days after order confirmation, with production lead times advised for larger quantities. International express, air cargo and sea freight can be selected according to destination and carton volume; customer courier accounts and nominated forwarders are also accepted.

Quality Assurance and Packaging

Functional inspection covers identification, link establishment and the condition of both connector assemblies. The cable is then protected against dust and connector damage and packed without sharp bends. Labels can include the customer reference and host-platform note when requested for a controlled deployment. Volume orders can include customer references on the labels and carton list.

Frequently Asked Questions

Is this an original equipment manufacturer cable?

No. It is manufactured by HT under our own manufacturer identity.

Does this order code cover multiple lengths?

No. QSFP28 to 4 duplex LC-100G-AOC-25M82FT refers here to 25m (82ft). Every other verified length has a separate part number and page in the length list.

Are separate transceivers or patch leads required?

No. This is one complete direct-attach assembly. The ends are not detachable modules and should not be separated from the cable.

Can excess cable be folded into a compact bundle?

No. Use a supported, bend-safe service loop and observe the listed minimum bend radius. Do not crease the cable or tighten ties around the connector boots.


About us

China Factory:No 168 Golden Ground Industrial Area;
Philippines Address:Makati City,Metro Manila, Philippines

Products catalogues

For products catalogue/data sheets or any general inquiry, please email info@huihongfiber.com and we will reply with details.

Customer Support

For customer support, please email sales@huihongfiber.com; our support team will get back to you as soon as possible.