
The QSFP56 to SFP56-200G-AOC-1M3FT compatible assembly addresses a specific interoperability requirement: Generic host identification on a 200G AOC link measuring 1m (3ft). Its interface configuration is QSFP56 to SFP56. This page explains the physical product, port-configuration checks and related part numbers so selection does not rely on connector appearance alone.
OEM Part Number: QSFP56 to SFP56-200G-AOC-1M3FTHT Part Number: QSFP56 to SFP56-200G-AOC-1M3FT
| HT Part Number | QSFP56 to SFP56-200G-AOC-1M3FT |
|---|---|
| Manufacturer | HT |
| Connector Type | QSFP56 to SFP56 |
| Max Data Rate | 200G |
| Minimum Bend Radius | 30mm |
| Cable Length | 1m (3ft) |
| Receiver Type | PIN |
| Transmitter Type | VSCEL |
| Temperature | 0 to 70°C (32 to 158°F) |
| Jacket Material | OFNP |
| Typical Power Consumption | 5.5W (QSFP56), 3W (SFP56) |
| Power Supply | 3.3V |
| Wavelength | 850nm |
| Fiber Type | OM3 Multimode Fiber (MMF) |
This assembly uses OFNP jacket, minimum bend radius 30mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.
At 1m (3ft), QSFP56 to SFP56-200G-AOC-1M3FT is a practical choice for direct connections within one rack. Route the cable along the intended management path rather than pulling it diagonally across adjacent connectors, and leave enough clearance for insertion, removal and front-panel airflow.
QSFP56 to SFP56-200G-AOC-1M3FT is the shortest of 12 verified length options in this family. It is the preferred choice when the port positions are close and cable slack must be kept to a minimum. The next option is QSFP56 to SFP56-200G-AOC-2M7FT at 2m (7ft), adding 1m for a less direct routing path; selecting it unnecessarily would leave more cable to dress.
Check three layers before deployment: the host must accept the cable identification, the port must support the stated aggregate rate, and the lane configuration must match the attached interfaces. On breakout hardware, also confirm channelization and the mapping of every branch. These checks are particularly important when similar-looking ports operate at different speeds or under different firmware settings. For this assembly, the minimum bend radius is 30mm; the jacket material is OFNP.
The QSFP56 to SFP56 configuration divides the high-speed interface into multiple lower-speed connections. Verify the upstream lane assignment, downstream port speeds and breakout setting on the host before connecting the assembly. Each branch must attach to the correct remote interface.
The optical engines and fiber are permanently integrated into this AOC. There are no detachable optical modules to clean or exchange. Handle the complete assembly by its connector housings and cable, and keep both ends matched to the same interface specification.
Specify the OEM part number and fixed length, then provide the intended host configuration if the link uses channelized or breakout ports. Separate part numbers should be used for separate lengths. This gives the compatibility review enough information to check both the physical assembly and the intended operating mode. Keep QSFP56 to SFP56-200G-AOC-1M3FT associated with 1m (3ft) throughout the order and receiving record.
The verification process combines digital identification with a live link test and diagnostic observation. Host model, hardware revision and software release are useful inputs because qualification behavior can change between platform generations; those details allow platform-specific requirements to be reviewed before the cable is packed. The check includes receive activity and diagnostic indications, followed by a final inspection of both ends.
Available stock is generally dispatched within one to three working days after order confirmation, with production lead times advised for larger quantities. Delivery can be arranged by courier, air freight or sea freight, and goods may instead be handed to an appointed forwarder or shipped on the customer’s courier account.
Functional inspection covers identification, link establishment and the condition of both connector assemblies. The cable is then protected against dust and connector damage and packed without sharp bends. Labels can include the customer reference and host-platform note when requested for a controlled deployment. Neutral packaging and customer-specific packing documentation are available on request.
No. It is manufactured by HT under our own manufacturer identity.
No. Use a supported, bend-safe service loop and observe the listed minimum bend radius. Do not crease the cable or tighten ties around the connector boots.
Not necessarily. Both hosts must support the stated rate, identification, lane mapping and any required breakout configuration; mechanical compatibility alone is insufficient.
Provide the equipment manufacturer, model, port type, hardware revision and software release, together with the OEM reference, required length and quantity.