Projects in the Philippines benefit from keeping the configuration, branch identification and installation requirement consistent across every participating site. This OM1 fiber patch cable carries a SC UPC interface on one end and a SC UPC interface on the other, factory terminated on OM1 glass and optically tested as a complete item. The duplex zipcord design keeps the transmit and receive strands paired in one item for fast, error-free patching.
| Connector A | SC UPC Duplex |
|---|---|
| Connector B | SC UPC Duplex |
| Fiber Count | 2 Fibers |
| Fiber Grade | G.651 |
| Fiber Mode | OM1 62.5/125μm |
| Wavelength | 850/1300nm |
| Flame Rating | Riser (OFNR) |
| Cable Outside Diameter (OD) | 2.0mm |
| Polarity | A (Tx) to B (Rx) |
| Cable Type | Tight-Buffered |
| Min. Bend Radius (Optical Fiber) | 15mm |
| Min. Bend Radius (Fiber Cable) | 20/10D (Dynamic/Static) |
| Connector Durability | 1000 times |
| Tensile Strength | 90/150N (Long/Short Term) |
| Insertion Loss | ≤0.3dB |
| Return Loss | ≥30dB |
| Attenuation at 850nm | ≤3.5dB/km |
| Attenuation at 1300nm | ≤1.5dB/km |
| Operating Temperature | -10 to 70°C (14 to 158℉) |
| Storage Temperature | -20 to 70°C (-4 to 158℉) |
OM1 and OM2 cabling remains in service in industrial controls, building automation and older campus networks. This factory-built assembly matches that plant: the 62.5/125 or 50/125 core mates correctly with the existing infrastructure, avoiding the modal mismatch that mixing core sizes would create.
When a legacy optical path fails, the right repair is a cord that matches the installed fiber grade. Patching OM1 with OM3 introduces a core-size transition that adds unpredictable loss; as a result, keeping a small stock of the right legacy jumpers is cheaper than fault isolation a mismatched one.
Standard size options cover the common patching routes: 1m (3ft), 2m (7ft), 3m (10ft), 5m (16ft), with customized length provided beyond the list. Specifying the measured channel length keeps the slack out of the manager and the strain off the mating connectors.
Each completed assembly is terminated with precision zirconia ferrule connectors and optically tested before packing: insertion loss and return loss are verified on each cable, and end-face geometry is inspected for consistent physical contact. The fiber cable ships with dust caps on both connectors and the test result provided on order.
Refer to this design by connector pair, fiber mode and length when submitting a request for a quotation. For configurations outside the listed options, mixed connector families, jackets, labeling or project packaging, send the need with the inquiry and the factory will validate the build before release to production. Customers in the Philippines can include multi-site labeling or documentation requirements when requesting a project quotation.