
The SFP-10G-AOC25M compatible assembly addresses a specific interoperability requirement: Cisco host identification on a 10G AOC link measuring 25m (82ft). Its interface configuration is SFP+ to SFP+. This page explains the physical product, port-configuration checks and related part numbers so selection does not rely on connector appearance alone.
OEM Part Number: SFP-10G-AOC25MHT Part Number: SFP-10G-AOC25M
| HT Part Number | SFP-10G-AOC25M |
|---|---|
| Cisco Compatible | SFP-10G-AOC25M |
| Manufacturer | HT |
| Connector Type | SFP+ to SFP+ |
| Max Data Rate | 10Gbps |
| Cable Type | OM3 |
| Cable Length | 25m (82.02ft) |
| Minimum Bend Radius | 30mm |
| Power Consumption | <0.8W |
| Jacket Material | OFNP |
| Temperature | 0 to 70°C (32 to 158°F) |
| Protocols | SFF-8636, 1xInfiniBand QDR,DDR,SDR, 10G Gigabit Ethernet |
The rated power consumption is <0.8W. Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.
Measure twice before deploying this 25m (82ft) cable: once along the planned route and again after accounting for service access. The objective is adequate reach without a concealed surplus. Support the integrated optical cable and both optical engines, preserve front-panel clearance and check that nearby power cords or sharp hardware cannot damage the jacket. Within this family, SFP-10G-AOC20M is shorter at 20m (66ft), while SFP-10G-AOC30M is the next longer choice at 30m (98ft); comparing those two boundaries helps avoid both tension and unnecessary slack.
SFP-10G-AOC25M occupies the middle of this family between SFP-10G-AOC20M at 20m (66ft) and SFP-10G-AOC30M at 30m (98ft). It adds 5m over the shorter option for extra routing clearance, while the next longer version adds another 5m. Measure the managed path and choose this version when its reach is sufficient without creating the slack associated with the longer assembly.
Check three layers before deployment: the host must accept the cable identification, the port must support the stated aggregate rate, and the lane configuration must match the attached interfaces. On breakout hardware, also confirm channelization and the mapping of every branch. These checks are particularly important when similar-looking ports operate at different speeds or under different firmware settings. For this assembly, the minimum bend radius is 30mm; the stated power consumption is <0.8W; the jacket material is OFNP.
This assembly uses OFNP jacket, minimum bend radius 30mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.
The intended application is determined by the host interface and protocol support. Listed interface and protocol references include SFF-8636, 1xInfiniBand QDR,DDR,SDR, 10G Gigabit Ethernet. Confirm that the host firmware and port configuration support the same operating mode.
The optical engines and fiber are permanently integrated into this AOC. There are no detachable optical modules to clean or exchange. Handle the complete assembly by its connector housings and cable, and keep both ends matched to the same interface specification.
Specify the OEM part number and fixed length, then provide the intended host configuration if the link uses channelized or breakout ports. Separate part numbers should be used for separate lengths. This gives the compatibility review enough information to check both the physical assembly and the intended operating mode. This page’s fixed configuration is 25m (82ft); another length must be quoted under its corresponding part number.
The verification process combines digital identification with a live link test and diagnostic observation. Host model, hardware revision and software release are useful inputs because qualification behavior can change between platform generations; those details allow platform-specific requirements to be reviewed before the cable is packed. Both connectors are examined before the operating test, which includes receive activity and diagnostic indications.
Standard configurations normally ship within one to three working days, while production quantities are confirmed with the order. Worldwide courier services are available, with air or sea freight for consolidated shipments; freight-collect delivery and coordination with a customer’s logistics provider can be arranged.
Functional inspection covers identification, link establishment and the condition of both connector assemblies. The cable is then protected against dust and connector damage and packed without sharp bends. Labels can include the customer reference and host-platform note when requested for a controlled deployment. Neutral packaging and customer-specific packing documentation are available on request.
No. It is an HT-manufactured compatible alternative for equipment that specifies Cisco SFP-10G-AOC25M.
No. This is one complete direct-attach assembly. The ends are not detachable modules and should not be separated from the cable.
No. Use a supported, bend-safe service loop and observe the listed minimum bend radius. Do not crease the cable or tighten ties around the connector boots.
Not necessarily. Both hosts must support the stated rate, identification, lane mapping and any required breakout configuration; mechanical compatibility alone is insufficient.