The SFP-DD to QSFP28-100G-AOC-30M98FT compatible assembly addresses a specific interoperability requirement: Generic host identification on a 100G AOC link measuring 30m (98ft). Its interface configuration is SFP-DD to QSFP28. This page explains the physical product, port-configuration checks and related part numbers so selection does not rely on connector appearance alone.
OEM Part Number: SFP-DD to QSFP28-100G-AOC-30M98FTHT Part Number: SFP-DD to QSFP28-100G-AOC-30M98FT
| HT Part Number | SFP-DD to QSFP28-100G-AOC-30M98FT |
|---|---|
| Manufacturer | HT |
| Connector Type | SFP-DD to QSFP28 |
| Max Data Rate | 100Gbps |
| Minimum Bend Radius | 30mm |
| Cable Length | 30m (98ft) |
| Jacket Material | OFNP |
| Cable Type | OM3 |
| Transmitter Type | VSCEL |
| Receiver Type | PIN |
| Wavelength | 850nm |
| Power Consumption | SFP-DD: <3.5WQSFP28: <5.5W |
| Modulation (Electrical) | SFP-DD-2x 50G-PAM4 QSFP28-4x 25G-NRZ |
| Modulation (Optical) | 2x 50G-PAM4 |
| Power supply | 3.3V |
| DDM/DOM | Supported |
| Commercial Temperature | 0 to 70°C (32 to 158°F) |
| Protocols | SFP-DD & QSFP28 MSA, IEEE 802.3cd, RoHS6 (Lead-free) |
| Application | 100GBASE SR2 Ethernet |
The listed modulation format is SFP-DD-2x 50G-PAM4 QSFP28-4x 25G-NRZ. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.
Check three layers before deployment: the host must accept the cable identification, the port must support the stated aggregate rate, and the lane configuration must match the attached interfaces. On breakout hardware, also confirm channelization and the mapping of every branch. These checks are particularly important when similar-looking ports operate at different speeds or under different firmware settings. For this assembly, the minimum bend radius is 30mm; the stated power consumption is SFP-DD: <3.5WQSFP28: <5.5W; the jacket material is OFNP.
The rated power consumption is SFP-DD: <3.5WQSFP28: <5.5W. Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.
This assembly uses OFNP jacket, minimum bend radius 30mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.
The intended application is 100GBASE SR2 Ethernet. Listed interface and protocol references include SFP-DD & QSFP28 MSA, IEEE 802.3cd, RoHS6 (Lead-free). Confirm that the host firmware and port configuration support the same operating mode.
The optical engines and fiber are permanently integrated into this AOC. There are no detachable optical modules to clean or exchange. Handle the complete assembly by its connector housings and cable, and keep both ends matched to the same interface specification.
With 30m (98ft) available, the installer has more routing freedom but also more cable to control. Determine where any remaining service loop will be stored, preserve the stated bend radius and keep the loop away from sharp edges and hot exhaust. The integrated optical cable and both optical engines should remain accessible for inspection and removal. The next shorter verified assembly is SFP-DD to QSFP28-100G-AOC-20M66FT at 20m (66ft), which is the better comparison when the managed route leaves substantial unused cable.
SFP-DD to QSFP28-100G-AOC-30M98FT is the longest of 9 verified length options in this family. Compared with SFP-DD to QSFP28-100G-AOC-20M66FT at 20m (66ft), it provides 10m of additional reach for a longer vertical drop, a wider rack or an adjacent-cabinet route. Confirm that the complete path requires this length, because unused slack still needs supported, bend-safe storage.
Specify the OEM part number and fixed length, then provide the intended host configuration if the link uses channelized or breakout ports. Separate part numbers should be used for separate lengths. This gives the compatibility review enough information to check both the physical assembly and the intended operating mode. Quantity and any labeling instructions should be attached specifically to SFP-DD to QSFP28-100G-AOC-30M98FT.
The verification process combines digital identification with a live link test and diagnostic observation. Host model, hardware revision and software release are useful inputs because qualification behavior can change between platform generations; those details allow platform-specific requirements to be reviewed before the cable is packed. Both connectors are examined before the operating test, which includes receive activity and diagnostic indications.
Available stock is generally dispatched within one to three working days after order confirmation, with production lead times advised for larger quantities. International express, air cargo and sea freight can be selected according to destination and carton volume; customer courier accounts and nominated forwarders are also accepted.
Functional inspection covers identification, link establishment and the condition of both connector assemblies. The cable is then protected against dust and connector damage and packed without sharp bends. Labels can include the customer reference and host-platform note when requested for a controlled deployment. Neutral packaging and customer-specific packing documentation are available on request.
No. It is manufactured by HT under our own manufacturer identity.
Only where both hosts explicitly support the complete interface and compatibility arrangement. Document each end and select the appropriate brand-specific product when required.
No. SFP-DD to QSFP28-100G-AOC-30M98FT refers here to 30m (98ft). Every other verified length has a separate part number and page in the length list.
No. This is one complete direct-attach assembly. The ends are not detachable modules and should not be separated from the cable.