SFP+ to SFP+-10G-AOC-30M98FT 10G SFP+ Active Optical Cable, 30m (98ft)

SFP+ to SFP+-10G-AOC-30M98FT 10G SFP+ Active Optical Cable, 30m (98ft)

The SFP+ to SFP+-10G-AOC-30M98FT compatible assembly addresses a specific interoperability requirement: Generic host identification on a 10G AOC link measuring 30m (98ft). Its interface configuration is SFP+ to SFP+. This page explains the physical product, port-configuration checks and related part numbers so selection does not rely on connector appearance alone.

OEM Part Number: SFP+ to SFP+-10G-AOC-30M98FTHT Part Number: SFP+ to SFP+-10G-AOC-30M98FT

Product Highlights

  • HT-manufactured AOC assembly in 30m (98ft)
  • 10G connectivity at 10Gbps
  • Interface configuration: SFP+ to SFP+
  • Fixed length and part number: 30m (98ft), SFP+ to SFP+-10G-AOC-30M98FT
  • Cable construction: OM3
  • Maximum power consumption: <0.8W
  • Minimum bend radius: 30mm

Specifications

HT Part NumberSFP+ to SFP+-10G-AOC-30M98FT
ManufacturerHT
Connector TypeSFP+ to SFP+
Max Data Rate10Gbps
Cable TypeOM3
Cable Length30m (98.43ft)
Minimum Bend Radius30mm
Power Consumption<0.8W
Jacket MaterialOFNP
Temperature0 to 70°C (32 to 158°F)
ProtocolsSFF-8636, 1xInfiniBand QDR,DDR,SDR, 10G Gigabit Ethernet

Power and Thermal Planning

The rated power consumption is <0.8W. Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.

Interoperability and Configuration Checks

Check three layers before deployment: the host must accept the cable identification, the port must support the stated aggregate rate, and the lane configuration must match the attached interfaces. On breakout hardware, also confirm channelization and the mapping of every branch. These checks are particularly important when similar-looking ports operate at different speeds or under different firmware settings. For this assembly, the minimum bend radius is 30mm; the stated power consumption is <0.8W; the jacket material is OFNP.

Cable Construction and Routing

This assembly uses OFNP jacket, minimum bend radius 30mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.

Network and Protocol Considerations

The intended application is determined by the host interface and protocol support. Listed interface and protocol references include SFF-8636, 1xInfiniBand QDR,DDR,SDR, 10G Gigabit Ethernet. Confirm that the host firmware and port configuration support the same operating mode.

Integrated Optical Assembly

The optical engines and fiber are permanently integrated into this AOC. There are no detachable optical modules to clean or exchange. Handle the complete assembly by its connector housings and cable, and keep both ends matched to the same interface specification.

Length Selection and Installation Planning

The extended 30m (98ft) configuration gives SFP+ to SFP+-10G-AOC-30M98FT a specific place in the family reach range. It should not be treated as a universal substitute for every shorter order code. Match it to a documented route, protect the integrated optical cable and both optical engines during handling and retain the part-number label for later maintenance. The next shorter verified assembly is SFP+ to SFP+-10G-AOC-25M82FT at 25m (82ft), which is the better comparison when the managed route leaves substantial unused cable.

Position Within the Length Range

SFP+ to SFP+-10G-AOC-30M98FT is the longest of 10 verified length options in this family. Compared with SFP+ to SFP+-10G-AOC-25M82FT at 25m (82ft), it provides 5m of additional reach for a longer vertical drop, a wider rack or an adjacent-cabinet route. Confirm that the complete path requires this length, because unused slack still needs supported, bend-safe storage.

Ordering Information

Specify the OEM part number and fixed length, then provide the intended host configuration if the link uses channelized or breakout ports. Separate part numbers should be used for separate lengths. This gives the compatibility review enough information to check both the physical assembly and the intended operating mode. Keep SFP+ to SFP+-10G-AOC-30M98FT associated with 30m (98ft) throughout the order and receiving record.

Generic Compatibility and Factory Testing

The verification process combines digital identification with a live link test and diagnostic observation. Host model, hardware revision and software release are useful inputs because qualification behavior can change between platform generations; those details allow platform-specific requirements to be reviewed before the cable is packed. The check includes receive activity and diagnostic indications, followed by a final inspection of both ends.

Shipping and Lead Time

Available stock is generally dispatched within one to three working days after order confirmation, with production lead times advised for larger quantities. Delivery can be arranged by courier, air freight or sea freight, and goods may instead be handed to an appointed forwarder or shipped on the customer’s courier account.

Quality Assurance and Packaging

Functional inspection covers identification, link establishment and the condition of both connector assemblies. The cable is then protected against dust and connector damage and packed without sharp bends. Labels can include the customer reference and host-platform note when requested for a controlled deployment. Volume orders can include customer references on the labels and carton list.

Frequently Asked Questions

Is this an original equipment manufacturer cable?

No. It is manufactured by HT under our own manufacturer identity.

Can excess cable be folded into a compact bundle?

No. Use a supported, bend-safe service loop and observe the listed minimum bend radius. Do not crease the cable or tighten ties around the connector boots.

Will any matching connector operate at the same speed?

Not necessarily. Both hosts must support the stated rate, identification, lane mapping and any required breakout configuration; mechanical compatibility alone is insufficient.

What details assist a compatibility review?

Provide the equipment manufacturer, model, port type, hardware revision and software release, together with the OEM reference, required length and quantity.


About us

China Factory:No 168 Golden Ground Industrial Area;
Philippines Address:Makati City,Metro Manila, Philippines

Products catalogues

For products catalogue/data sheets or any general inquiry, please email info@huihongfiber.com and we will reply with details.

Customer Support

For customer support, please email sales@huihongfiber.com; our support team will get back to you as soon as possible.