
A successful 10G link depends on host acceptance as well as physical fit. This SFP-XG-D-AOC-10M compatible AOC assembly combines SFP+ to SFP+ with a fixed 10m (33ft) cable for H3C equipment. The specifications, configuration guidance and live-link factory verification below describe the exact product supplied under this reference.
OEM Part Number: SFP-XG-D-AOC-10MHT Part Number: SFP-XG-D-AOC-10M
| HT Part Number | SFP-XG-D-AOC-10M |
|---|---|
| H3C Compatible | SFP-XG-D-AOC-10M |
| Manufacturer | HT |
| Connector Type | SFP+ to SFP+ |
| Max Data Rate | 10Gbps |
| Cable Type | OM2/OM3 |
| Cable Length | 10m (32.81ft) |
| Minimum Bend Radius | 30mm |
| Power Consumption | <0.8W |
| Jacket Material | OFNP |
| Temperature | 0 to 70°C (32 to 158°F) |
| Protocols | SFF-8636, 1xInfiniBand QDR,DDR,SDR, 10G Gigabit Ethernet |
The rated power consumption is <0.8W. Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.
For this 10m (33ft) version, prepare the destination pathway before connecting either end. A longer assembly can cross separated equipment positions, but its weight and service slack must remain supported without blocking airflow. Handle the integrated optical cable and both optical engines as one factory-terminated product and never pull a connector into position by the cable. Within this family, SFP-XG-D-AOC-7M is shorter at 7m (23ft), while SFP-XG-D-AOC-15M is the next longer choice at 15m (49ft); comparing those two boundaries helps avoid both tension and unnecessary slack.
SFP-XG-D-AOC-10M occupies the middle of this family between SFP-XG-D-AOC-7M at 7m (23ft) and SFP-XG-D-AOC-15M at 15m (49ft). It adds 3m over the shorter option for extra routing clearance, while the next longer version adds another 5m. Measure the managed path and choose this version when its reach is sufficient without creating the slack associated with the longer assembly.
Check three layers before deployment: the host must accept the cable identification, the port must support the stated aggregate rate, and the lane configuration must match the attached interfaces. On breakout hardware, also confirm channelization and the mapping of every branch. These checks are particularly important when similar-looking ports operate at different speeds or under different firmware settings. For this assembly, the minimum bend radius is 30mm; the stated power consumption is <0.8W; the jacket material is OFNP.
This assembly uses OFNP jacket, minimum bend radius 30mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.
The intended application is determined by the host interface and protocol support. Listed interface and protocol references include SFF-8636, 1xInfiniBand QDR,DDR,SDR, 10G Gigabit Ethernet. Confirm that the host firmware and port configuration support the same operating mode.
The optical engines and fiber are permanently integrated into this AOC. There are no detachable optical modules to clean or exchange. Handle the complete assembly by its connector housings and cable, and keep both ends matched to the same interface specification.
Specify the OEM part number and fixed length, then provide the intended host configuration if the link uses channelized or breakout ports. Separate part numbers should be used for separate lengths. This gives the compatibility review enough information to check both the physical assembly and the intended operating mode. Keep SFP-XG-D-AOC-10M associated with 10m (33ft) throughout the order and receiving record.
The verification process combines digital identification with a live link test and diagnostic observation. Host model, hardware revision and software release are useful inputs because qualification behavior can change between platform generations; those details allow platform-specific requirements to be reviewed before the cable is packed. The check includes receive activity and diagnostic indications, followed by a final inspection of both ends.
Available stock is generally dispatched within one to three working days after order confirmation, with production lead times advised for larger quantities. International express, air cargo and sea freight can be selected according to destination and carton volume; customer courier accounts and nominated forwarders are also accepted.
Functional inspection covers identification, link establishment and the condition of both connector assemblies. The cable is then protected against dust and connector damage and packed without sharp bends. Labels can include the customer reference and host-platform note when requested for a controlled deployment. Standard protective packing is used by default, with project documentation arranged when requested.
No. It is an HT-manufactured compatible alternative for equipment that specifies H3C SFP-XG-D-AOC-10M.
Provide the equipment manufacturer, model, port type, hardware revision and software release, together with the OEM reference, required length and quantity.
Protect both connector ends, keep the cable in a loose bend-safe coil and retain its part-number label so the length and compatibility identity remain traceable.
Only where both hosts explicitly support the complete interface and compatibility arrangement. Document each end and select the appropriate brand-specific product when required.