
Use this 70m (229ft) AOC cable for hosts expecting Generic SFP28-25G-AOC-70M229FT and a 25G direct-attached interface. The assembly uses SFP28; lane, protocol and breakout considerations are documented alongside the verified table. Every alternative length remains a separate order code with its own technical page.
OEM Part Number: SFP28-25G-AOC-70M229FTHT Part Number: SFP28-25G-AOC-70M229FT
| HT Part Number | SFP28-25G-AOC-70M229FT |
|---|---|
| Manufacturer | HT |
| Form Factor | SFP28 |
| Max Data Rate | 25.78125Gbps |
| Wavelength | 850nm |
| Cable Type | OM3 |
| Minimum Bend Radius | 30mm |
| Cable Length | 70m(229ft) |
| Power Consumption | < 1W |
| Jacket Material | OFNP |
| Industrial Temperature Range | -40 to 85°C (-40 to 185°F) |
| Protocols | SFP28 MSA,IEEE 802.3by 25GBASE-SR |
The rated power consumption is < 1W. Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.
A 70m (229ft) run can remain tidy when its pathway and service allowance are planned together. Keep the integrated optical cable and both optical engines away from tight cable-tie pressure, verify bend control at changes of direction and ensure that neither port supports the assembly’s weight. Record the exact order code after acceptance. The next shorter verified assembly is SFP28-25G-AOC-50M164FT at 50m (164ft), which is the better comparison when the managed route leaves substantial unused cable.
SFP28-25G-AOC-70M229FT is the longest of 12 verified length options in this family. Compared with SFP28-25G-AOC-50M164FT at 50m (164ft), it provides 20m of additional reach for a longer vertical drop, a wider rack or an adjacent-cabinet route. Confirm that the complete path requires this length, because unused slack still needs supported, bend-safe storage.
Check three layers before deployment: the host must accept the cable identification, the port must support the stated aggregate rate, and the lane configuration must match the attached interfaces. On breakout hardware, also confirm channelization and the mapping of every branch. These checks are particularly important when similar-looking ports operate at different speeds or under different firmware settings. For this assembly, the minimum bend radius is 30mm; the stated power consumption is < 1W; the jacket material is OFNP.
This assembly uses OFNP jacket, minimum bend radius 30mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.
The intended application is determined by the host interface and protocol support. Listed interface and protocol references include SFP28 MSA,IEEE 802.3by 25GBASE-SR. Confirm that the host firmware and port configuration support the same operating mode.
The optical engines and fiber are permanently integrated into this AOC. There are no detachable optical modules to clean or exchange. Handle the complete assembly by its connector housings and cable, and keep both ends matched to the same interface specification.
Specify the OEM part number and fixed length, then provide the intended host configuration if the link uses channelized or breakout ports. Separate part numbers should be used for separate lengths. This gives the compatibility review enough information to check both the physical assembly and the intended operating mode. This page’s fixed configuration is 70m (229ft); another length must be quoted under its corresponding part number.
The verification process combines digital identification with a live link test and diagnostic observation. Host model, hardware revision and software release are useful inputs because qualification behavior can change between platform generations; those details allow platform-specific requirements to be reviewed before the cable is packed. Where supported by the host, receive activity and diagnostic indications are reviewed together with the established link.
Standard configurations normally ship within one to three working days, while production quantities are confirmed with the order. Worldwide courier services are available, with air or sea freight for consolidated shipments; freight-collect delivery and coordination with a customer’s logistics provider can be arranged.
Functional inspection covers identification, link establishment and the condition of both connector assemblies. The cable is then protected against dust and connector damage and packed without sharp bends. Labels can include the customer reference and host-platform note when requested for a controlled deployment. Standard protective packing is used by default, with project documentation arranged when requested.
No. It is manufactured by HT under our own manufacturer identity.
Provide the equipment manufacturer, model, port type, hardware revision and software release, together with the OEM reference, required length and quantity.
Protect both connector ends, keep the cable in a loose bend-safe coil and retain its part-number label so the length and compatibility identity remain traceable.
Only where both hosts explicitly support the complete interface and compatibility arrangement. Document each end and select the appropriate brand-specific product when required.