A successful 25G link depends on host acceptance as well as physical fit. This SFP28-25G-AOC7M compatible AOC assembly combines SFP28 to SFP28 with a fixed 7m (23ft) cable for Cisco equipment. The specifications, configuration guidance and live-link factory verification below describe the exact product supplied under this reference.
OEM Part Number: SFP28-25G-AOC7MHT Part Number: SFP28-25G-AOC7M
| HT Part Number | SFP28-25G-AOC7M |
|---|---|
| Cisco Compatible | SFP28-25G-AOC7M |
| Manufacturer | HT |
| Connector Type | SFP28 to SFP28 |
| Max Data Rate | 25Gbps |
| Minimum Bend Radius | 30mm |
| Cable Length | 7m (22.97ft) |
| Jacket Material | OFNP |
| Temperature | 0 to 70°C (32 to 158°F) |
This assembly uses OFNP jacket, minimum bend radius 30mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.
The optical engines and fiber are permanently integrated into this AOC. There are no detachable optical modules to clean or exchange. Handle the complete assembly by its connector housings and cable, and keep both ends matched to the same interface specification.
At 7m (23ft), SFP28-25G-AOC7M should be planned as an extended equipment-room connection rather than a short in-rack jumper. Mark the complete vertical and horizontal route before installation, including every manager the cable will actually pass through. Support the integrated optical cable and both optical engines along that path and keep both ends free from pull loads. Within this family, SFP28-25G-AOC5M is shorter at 5m (16ft), while SFP28-25G-AOC10M is the next longer choice at 10m (33ft); comparing those two boundaries helps avoid both tension and unnecessary slack.
SFP28-25G-AOC7M occupies the middle of this family between SFP28-25G-AOC5M at 5m (16ft) and SFP28-25G-AOC10M at 10m (33ft). It adds 2m over the shorter option for extra routing clearance, while the next longer version adds another 3m. Measure the managed path and choose this version when its reach is sufficient without creating the slack associated with the longer assembly.
Check three layers before deployment: the host must accept the cable identification, the port must support the stated aggregate rate, and the lane configuration must match the attached interfaces. On breakout hardware, also confirm channelization and the mapping of every branch. These checks are particularly important when similar-looking ports operate at different speeds or under different firmware settings. For this assembly, the minimum bend radius is 30mm; the jacket material is OFNP.
Specify the OEM part number and fixed length, then provide the intended host configuration if the link uses channelized or breakout ports. Separate part numbers should be used for separate lengths. This gives the compatibility review enough information to check both the physical assembly and the intended operating mode. Quantity and any labeling instructions should be attached specifically to SFP28-25G-AOC7M.
The verification process combines digital identification with a live link test and diagnostic observation. Host model, hardware revision and software release are useful inputs because qualification behavior can change between platform generations; those details allow platform-specific requirements to be reviewed before the cable is packed. Where supported by the host, receive activity and diagnostic indications are reviewed together with the established link.
Available stock is generally dispatched within one to three working days after order confirmation, with production lead times advised for larger quantities. Delivery can be arranged by courier, air freight or sea freight, and goods may instead be handed to an appointed forwarder or shipped on the customer’s courier account.
Functional inspection covers identification, link establishment and the condition of both connector assemblies. The cable is then protected against dust and connector damage and packed without sharp bends. Labels can include the customer reference and host-platform note when requested for a controlled deployment. Standard protective packing is used by default, with project documentation arranged when requested.
No. It is an HT-manufactured compatible alternative for equipment that specifies Cisco SFP28-25G-AOC7M.
Provide the equipment manufacturer, model, port type, hardware revision and software release, together with the OEM reference, required length and quantity.
Protect both connector ends, keep the cable in a loose bend-safe coil and retain its part-number label so the length and compatibility identity remain traceable.
Only where both hosts explicitly support the complete interface and compatibility arrangement. Document each end and select the appropriate brand-specific product when required.