The SFP56-50G-AOC-50M164FT compatible assembly addresses a specific interoperability requirement: Generic host identification on a 50G AOC link measuring 50m (164ft). Its interface configuration is SFP56. This page explains the physical product, port-configuration checks and related part numbers so selection does not rely on connector appearance alone.
OEM Part Number: SFP56-50G-AOC-50M164FTHT Part Number: SFP56-50G-AOC-50M164FT
| HT Part Number | SFP56-50G-AOC-50M164FT |
|---|---|
| Manufacturer | HT |
| Form Factor | SFP56 |
| Max Data Rate | 50Gbps |
| Cable Type | Optical Cable |
| Max Cable Distance | Up to 50m |
| Cable Length | 1m (3ft) |
| Minimum Bend Radius | 60mm |
| Power Consumption | ≤2W |
| Jacket Material | OFNP |
| Receiver Type | PIN |
| Transmitter Type | VSCEL |
| FEC Function | Support Pre-FEC |
| CDR | TX+RX |
| Modulation Format | PAM4 |
| Temperature | 0 to 70°C (32 to 158°F) |
| Protocol | IEEE 802.3cd SFP56 MSA |
The listed modulation format is PAM4. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.
At 50m (164ft), SFP56-50G-AOC-50M164FT should be planned as an extended equipment-room connection rather than a short in-rack jumper. Mark the complete vertical and horizontal route before installation, including every manager the cable will actually pass through. Support the integrated optical cable and both optical engines along that path and keep both ends free from pull loads. The next shorter verified assembly is SFP56-50G-AOC-30M98FT at 30m (98ft), which is the better comparison when the managed route leaves substantial unused cable.
SFP56-50G-AOC-50M164FT is the longest of 10 verified length options in this family. Compared with SFP56-50G-AOC-30M98FT at 30m (98ft), it provides 20m of additional reach for a longer vertical drop, a wider rack or an adjacent-cabinet route. Confirm that the complete path requires this length, because unused slack still needs supported, bend-safe storage.
Check three layers before deployment: the host must accept the cable identification, the port must support the stated aggregate rate, and the lane configuration must match the attached interfaces. On breakout hardware, also confirm channelization and the mapping of every branch. These checks are particularly important when similar-looking ports operate at different speeds or under different firmware settings. For this assembly, the minimum bend radius is 60mm; the stated power consumption is ≤2W; the jacket material is OFNP.
The rated power consumption is ≤2W. Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.
This assembly uses OFNP jacket, minimum bend radius 60mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.
The optical engines and fiber are permanently integrated into this AOC. There are no detachable optical modules to clean or exchange. Handle the complete assembly by its connector housings and cable, and keep both ends matched to the same interface specification.
Specify the OEM part number and fixed length, then provide the intended host configuration if the link uses channelized or breakout ports. Separate part numbers should be used for separate lengths. This gives the compatibility review enough information to check both the physical assembly and the intended operating mode. Keep SFP56-50G-AOC-50M164FT associated with 50m (164ft) throughout the order and receiving record.
The verification process combines digital identification with a live link test and diagnostic observation. Host model, hardware revision and software release are useful inputs because qualification behavior can change between platform generations; those details allow platform-specific requirements to be reviewed before the cable is packed. Where supported by the host, receive activity and diagnostic indications are reviewed together with the established link.
Available stock is generally dispatched within one to three working days after order confirmation, with production lead times advised for larger quantities. Worldwide courier services are available, with air or sea freight for consolidated shipments; freight-collect delivery and coordination with a customer’s logistics provider can be arranged.
Functional inspection covers identification, link establishment and the condition of both connector assemblies. The cable is then protected against dust and connector damage and packed without sharp bends. Labels can include the customer reference and host-platform note when requested for a controlled deployment. Volume orders can include customer references on the labels and carton list.
No. It is manufactured by HT under our own manufacturer identity.
Provide the equipment manufacturer, model, port type, hardware revision and software release, together with the OEM reference, required length and quantity.
Protect both connector ends, keep the cable in a loose bend-safe coil and retain its part-number label so the length and compatibility identity remain traceable.
Only where both hosts explicitly support the complete interface and compatibility arrangement. Document each end and select the appropriate brand-specific product when required.