Philippines Fiber Optics

Connect the people, connect the world ...

Fiber Optic Cables

Intel XDACBL7M Compatible 10G SFP+ Passive Copper Twinax Cable, 7m (23ft)

Intel XDACBL7M Compatible 10G SFP+ Passive Copper Twinax Cable, 7m (23ft)

Use this 7m (23ft) DAC cable for hosts expecting Intel XDACBL7M and a 10G direct-attached interface. The assembly uses SFP+ to SFP+; lane, protocol and breakout considerations are documented alongside the verified table. Every alternative length remains a separate order code with its own technical page.

OEM Part Number: XDACBL7MHT Part Number: XDACBL7M

Product Highlights

  • Compatible alternative to Intel XDACBL7M
  • 10G connectivity at 10Gbps
  • Interface configuration: SFP+ to SFP+
  • Fixed length and part number: 7m (23ft), XDACBL7M
  • Cable construction: Passive Twinax
  • Conductor specification: 24AWG
  • Maximum power consumption: ≤0.1W
  • Minimum bend radius: 30mm

Specifications

HT Part NumberXDACBL7M
Intel CompatibleSFP-H10GB-CU7M
ManufacturerHT
Connector TypeSFP+ to SFP+
Max Data Rate10Gbps
MediaCopper
Power Supply3.3V
Minimum Bend Radius30mm
Wire AWG24AWG
Cable Length7m (22.97ft)
Jacket MaterialPVC (OFNR)
Cable TypePassive Twinax
Temperature0 to 70°C (32 to 158°F)
Power Consumption≤0.1W
Application10G Ethernet
Protocols1x InfiniBand QDR, DDR, SDR, 10 Gigabit Ethernet, Fibre Channel

Power and Thermal Planning

The rated power consumption is ≤0.1W. Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.

Length Selection and Installation Planning

A 7m (23ft) run can remain tidy when its pathway and service allowance are planned together. Keep the complete copper assembly and both connector housings away from tight cable-tie pressure, verify bend control at changes of direction and ensure that neither port supports the assembly’s weight. Record the exact order code after acceptance. The next shorter verified assembly is XDACBL6M at 6m (20ft), which is the better comparison when the managed route leaves substantial unused cable.

Position Within the Length Range

XDACBL7M is the longest of 10 verified length options in this family. Compared with XDACBL6M at 6m (20ft), it provides 1m of additional reach for a longer vertical drop, a wider rack or an adjacent-cabinet route. Confirm that the complete path requires this length, because unused slack still needs supported, bend-safe storage.

Interoperability and Configuration Checks

Check three layers before deployment: the host must accept the cable identification, the port must support the stated aggregate rate, and the lane configuration must match the attached interfaces. On breakout hardware, also confirm channelization and the mapping of every branch. These checks are particularly important when similar-looking ports operate at different speeds or under different firmware settings. For this assembly, the listed conductor specification is 24AWG; the minimum bend radius is 30mm; the stated power consumption is ≤0.1W; the jacket material is PVC (OFNR).

Cable Construction and Routing

This assembly uses 24AWG conductors, PVC (OFNR) jacket, minimum bend radius 30mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.

Network and Protocol Considerations

The intended application is 10G Ethernet. Listed interface and protocol references include 1x InfiniBand QDR, DDR, SDR, 10 Gigabit Ethernet, Fibre Channel. Confirm that the host firmware and port configuration support the same operating mode.

Passive Copper Operation

A passive DAC has no separate optical conversion stage. Its low-power, low-latency operation is useful for short equipment links, but the assembly must remain within the length and signaling mode accepted by both hosts.

Ordering Information

Specify the OEM part number and fixed length, then provide the intended host configuration if the link uses channelized or breakout ports. Separate part numbers should be used for separate lengths. This gives the compatibility review enough information to check both the physical assembly and the intended operating mode. Quantity and any labeling instructions should be attached specifically to XDACBL7M.

Intel Compatibility and Factory Testing

The verification process combines digital identification with a live link test and diagnostic observation. Host model, hardware revision and software release are useful inputs because qualification behavior can change between platform generations; those details allow platform-specific requirements to be reviewed before the cable is packed. Both connectors are examined before the operating test, which includes link stability and diagnostic indications.

Shipping and Lead Time

Available stock is generally dispatched within one to three working days after order confirmation, with production lead times advised for larger quantities. Delivery can be arranged by courier, air freight or sea freight, and goods may instead be handed to an appointed forwarder or shipped on the customer’s courier account.

Quality Assurance and Packaging

Functional inspection covers identification, link establishment and the condition of both connector assemblies. The cable is then protected against dust and connector damage and packed without sharp bends. Labels can include the customer reference and host-platform note when requested for a controlled deployment. Neutral packaging and customer-specific packing documentation are available on request.

Frequently Asked Questions

Is this an original Intel cable?

No. It is an HT-manufactured compatible alternative for equipment that specifies Intel XDACBL7M.

Can excess cable be folded into a compact bundle?

No. Use a supported, bend-safe service loop and observe the listed minimum bend radius. Do not crease the cable or tighten ties around the connector boots.

Will any matching connector operate at the same speed?

Not necessarily. Both hosts must support the stated rate, identification, lane mapping and any required breakout configuration; mechanical compatibility alone is insufficient.

What details assist a compatibility review?

Provide the equipment manufacturer, model, port type, hardware revision and software release, together with the OEM reference, required length and quantity.


About us

China Factory:No 168 Golden Ground Industrial Area;
Philippines Address:Makati City,Metro Manila, Philippines

Products catalogues

For products catalogue/data sheets or any general inquiry, please email info@huihongfiber.com and we will reply with details.

Customer Support

For customer support, please email sales@huihongfiber.com; our support team will get back to you as soon as possible.