Philippines Fiber Optics

Connect the people, connect the world ...

Fiber Optic Cables

Dell AOC-Q28DD-2Q28-100G-20M Compatible 200G QSFP-DD 8 x 25G NRZ to 2 x 100G QSFP28 4 x 25G NRZ Active Optical Breakout Cable, 20m (66ft)

Dell AOC-Q28DD-2Q28-100G-20M Compatible 200G QSFP-DD 8 x 25G NRZ to 2 x 100G QSFP28 4 x 25G NRZ Active Optical Breakout Cable, 20m (66ft)

A successful 200G link depends on host acceptance as well as physical fit. This AOC-Q28DD-2Q28-100G-20M compatible AOC assembly combines QSFP-DD to 2x 100G QSFP28 with a fixed 20m (66ft) cable for Dell equipment. The specifications, configuration guidance and live-link factory verification below describe the exact product supplied under this reference.

OEM Part Number: AOC-Q28DD-2Q28-100G-20MHT Part Number: AOC-Q28DD-2Q28-100G-20M

Product Highlights

  • Compatible alternative to Dell AOC-Q28DD-2Q28-100G-20M
  • 200G connectivity at 200Gbps
  • Interface configuration: QSFP-DD to 2x 100G QSFP28
  • Fixed length and part number: 20m (66ft), AOC-Q28DD-2Q28-100G-20M
  • Cable construction: OM3
  • Maximum power consumption: 4W (QSFP-DD End) 2.5W (QSFP28 Per End)
  • Minimum bend radius: 30mm
  • Operating temperature: 0 to 70°C (32 to 158°F)

Specifications

HT Part NumberAOC-Q28DD-2Q28-100G-20M
Dell CompatibleAOC-Q28DD-2Q28-100G-20M
ManufacturerHT
Form FactorQSFP-DD to 2x 100G QSFP28
Max. Data Rate200Gbps
Cable Length20m (66ft)
Cable TypeOM3
Wavelength850nm
Minimum Bend Radius30mm
Transmitter TypeVSCEL
Receiver TypePIN
Max. Power Consumption4W (QSFP-DD End) 2.5W (QSFP28 Per End)
Jacket MaterialOFNP
CDR (Clock and Data Recovery)Not Supported
Modulation FormatNRZ
Commercial Temperature Range0 to 70°C (32 to 158°F)
ProtocolsQSFP-DD MSA V5.0, QSFP28 MSA, CMIS V4.0, SFF-8636

Signal and Lane Configuration

The listed modulation format is NRZ. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.

Cable Construction and Routing

This assembly uses OFNP jacket, minimum bend radius 30mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.

Network and Protocol Considerations

The intended application is determined by the host interface and protocol support. Listed interface and protocol references include QSFP-DD MSA V5.0, QSFP28 MSA, CMIS V4.0, SFF-8636. Confirm that the host firmware and port configuration support the same operating mode.

Breakout Port Mapping

The QSFP-DD to 2x 100G QSFP28 configuration divides the high-speed interface into multiple lower-speed connections. Verify the upstream lane assignment, downstream port speeds and breakout setting on the host before connecting the assembly. Each branch must attach to the correct remote interface.

Integrated Optical Assembly

The optical engines and fiber are permanently integrated into this AOC. There are no detachable optical modules to clean or exchange. Handle the complete assembly by its connector housings and cable, and keep both ends matched to the same interface specification.

Length Selection and Installation Planning

This 20m (66ft) assembly is intended for routes that shorter members of the same family cannot serve comfortably. Before ordering, document the actual pathway and the space available for service access. During installation, secure the integrated optical cable and both optical engines without compressing it into an undersized bundle or leaving its weight suspended from the ports. The next shorter verified assembly is AOC-Q28DD-2Q28-100G-15M at 15m (49ft), which is the better comparison when the managed route leaves substantial unused cable.

Position Within the Length Range

AOC-Q28DD-2Q28-100G-20M is the longest of 6 verified length options in this family. Compared with AOC-Q28DD-2Q28-100G-15M at 15m (49ft), it provides 5m of additional reach for a longer vertical drop, a wider rack or an adjacent-cabinet route. Confirm that the complete path requires this length, because unused slack still needs supported, bend-safe storage.

Interoperability and Configuration Checks

Check three layers before deployment: the host must accept the cable identification, the port must support the stated aggregate rate, and the lane configuration must match the attached interfaces. On breakout hardware, also confirm channelization and the mapping of every branch. These checks are particularly important when similar-looking ports operate at different speeds or under different firmware settings. For this assembly, the minimum bend radius is 30mm; the stated power consumption is 4W (QSFP-DD End) 2.5W (QSFP28 Per End); the jacket material is OFNP.

Power and Thermal Planning

The rated power consumption is 4W (QSFP-DD End) 2.5W (QSFP28 Per End). Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.

Ordering Information

Specify the OEM part number and fixed length, then provide the intended host configuration if the link uses channelized or breakout ports. Separate part numbers should be used for separate lengths. This gives the compatibility review enough information to check both the physical assembly and the intended operating mode. Keep AOC-Q28DD-2Q28-100G-20M associated with 20m (66ft) throughout the order and receiving record.

Dell Compatibility and Factory Testing

The verification process combines digital identification with a live link test and diagnostic observation. Host model, hardware revision and software release are useful inputs because qualification behavior can change between platform generations; those details allow platform-specific requirements to be reviewed before the cable is packed. The check includes receive activity and diagnostic indications, followed by a final inspection of both ends.

Shipping and Lead Time

Standard configurations normally ship within one to three working days, while production quantities are confirmed with the order. International express, air cargo and sea freight can be selected according to destination and carton volume; customer courier accounts and nominated forwarders are also accepted.

Quality Assurance and Packaging

Functional inspection covers identification, link establishment and the condition of both connector assemblies. The cable is then protected against dust and connector damage and packed without sharp bends. Labels can include the customer reference and host-platform note when requested for a controlled deployment. Standard protective packing is used by default, with project documentation arranged when requested.

Frequently Asked Questions

Is this an original Dell cable?

No. It is an HT-manufactured compatible alternative for equipment that specifies Dell AOC-Q28DD-2Q28-100G-20M.

What details assist a compatibility review?

Provide the equipment manufacturer, model, port type, hardware revision and software release, together with the OEM reference, required length and quantity.

How should an unused assembly be stored?

Protect both connector ends, keep the cable in a loose bend-safe coil and retain its part-number label so the length and compatibility identity remain traceable.

Can different brands be connected with the same assembly?

Only where both hosts explicitly support the complete interface and compatibility arrangement. Document each end and select the appropriate brand-specific product when required.


About us

China Factory:No 168 Golden Ground Industrial Area;
Philippines Address:Makati City,Metro Manila, Philippines

Products catalogues

For products catalogue/data sheets or any general inquiry, please email info@huihongfiber.com and we will reply with details.

Customer Support

For customer support, please email sales@huihongfiber.com; our support team will get back to you as soon as possible.